This page is part of the FHIR Specification (v5.0.0: R5 - STU). This is the current published version. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Example CodeSystem/allergy-intolerance-criticality (XML)
Raw XML (canonical form + also see XML Format Specification)
Definition for Code SystemAllergyIntoleranceCriticality
<?xml version="1.0" encoding="UTF-8"?>
<CodeSystem xmlns="http://hl7.org/fhir">
<id value="allergy-intolerance-criticality"/>
<meta>
<lastUpdated value="2023-03-26T15:21:02.749+11:00"/>
<profile value="http://hl7.org/fhir/StructureDefinition/shareablecodesystem"/>
</meta>
<text>
<status value="generated"/>
<div xmlns="http://www.w3.org/1999/xhtml">
<p> This code system
<code> http://hl7.org/fhir/allergy-intolerance-criticality</code> defines the following codes:
</p>
<table class="codes">
<tr>
<td style="white-space:nowrap">
<b> Code</b>
</td>
<td>
<b> Display</b>
</td>
<td>
<b> Definition</b>
</td>
</tr>
<tr>
<td style="white-space:nowrap">low
<a name="allergy-intolerance-criticality-low"> </a>
</td>
<td> Low Risk</td>
<td> Worst case result of a future exposure is not assessed to be life-threatening or
having high potential for organ system failure.</td>
</tr>
<tr>
<td style="white-space:nowrap">high
<a name="allergy-intolerance-criticality-high"> </a>
</td>
<td> High Risk</td>
<td> Worst case result of a future exposure is assessed to be life-threatening or having
high potential for organ system failure.</td>
</tr>
<tr>
<td style="white-space:nowrap">unable-to-assess
<a name="allergy-intolerance-criticality-unable-to-assess"> </a>
</td>
<td> Unable to Assess Risk</td>
<td> Unable to assess the worst case result of a future exposure.</td>
</tr>
</table>
</div>
</text>
<extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
<valueCode value="pc"/>
</extension>
<extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status">
<valueCode value="trial-use"/>
</extension>
<extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm">
<valueInteger value="3"/>
</extension>
<url value="http://hl7.org/fhir/allergy-intolerance-criticality"/>
<identifier>
<system value="urn:ietf:rfc:3986"/>
<value value="urn:oid:2.16.840.1.113883.4.642.4.130"/>
</identifier>
<identifier>
<use value="old"/>
<system value="urn:ietf:rfc:3986"/>
<value value="urn:oid:2.16.840.1.113883.4.642.1.120"/>
</identifier>
<identifier>
<use value="old"/>
<system value="urn:ietf:rfc:3986"/>
<value value="urn:oid:2.16.840.1.113883.4.642.2.51"/>
</identifier>
<version value="5.0.0"/>
<name value="AllergyIntoleranceCriticality"/>
<title value="Allergy Intolerance Criticality"/>
<status value="active"/>
<experimental value="false"/>
<date value="2021-01-05T10:01:24+11:00"/>
<publisher value="HL7 (FHIR Project)"/>
<contact>
<telecom>
<system value="url"/>
<value value="http://hl7.org/fhir"/>
</telecom>
<telecom>
<system value="email"/>
<value value="fhir@lists.hl7.org"/>
</telecom>
</contact>
<description value="Estimate of the potential clinical harm, or seriousness, of a reaction to an identified
substance."/>
<jurisdiction>
<coding>
<system value="http://unstats.un.org/unsd/methods/m49/m49.htm"/>
<code value="001"/>
<display value="World"/>
</coding>
</jurisdiction>
<caseSensitive value="true"/>
<valueSet value="http://hl7.org/fhir/ValueSet/allergy-intolerance-criticality"/>
<content value="complete"/>
<concept>
<code value="low"/>
<display value="Low Risk"/>
<definition value="Worst case result of a future exposure is not assessed to be life-threatening or
having high potential for organ system failure."/>
</concept>
<concept>
<code value="high"/>
<display value="High Risk"/>
<definition value="Worst case result of a future exposure is assessed to be life-threatening or having
high potential for organ system failure."/>
</concept>
<concept>
<code value="unable-to-assess"/>
<display value="Unable to Assess Risk"/>
<definition value="Unable to assess the worst case result of a future exposure."/>
</concept>
</CodeSystem>
Usage note: every effort has been made to ensure that the
examples are correct and useful, but they are not a normative part
of the specification.