FHIR Release 3 (STU)

This page is part of the FHIR Specification (v3.0.2: STU 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Guidanceresponse-example.xml

Clinical Decision Support Work GroupMaturity Level: N/ABallot Status: InformativeCompartments: Not linked to any defined compartments

Raw XML (canonical form)

Jump past Narrative

Example of guidanceresponse (id = "example")

<GuidanceResponse xmlns="http://hl7.org/fhir">
  <id value="example"/> 
  <!--    This example demonstrates the response to an $evaluate operation using the GuidanceResponse
   resource.    -->
  <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative with Details</b> </p> <p> <b> id</b> : example</p> <p> <b> contained</b> : </p> <p> <b> requestId</b> : guidanceRequest1</p> <p> <b> identifier</b> : guidanceResponse1</p> <p> <b> module</b> : <a> ServiceDefinition/example</a> </p> <p> <b> status</b> : success</p> <p> <b> subject</b> : <a> Patient/example</a> </p> <p> <b> context</b> : <a> Encounter/example</a> </p> <p> <b> occurrenceDateTime</b> : 10/03/2017 4:02:00 PM</p> <p> <b> performer</b> : <a> Device/software</a> </p> <p> <b> reason</b> : Guideline Appropriate Ordering Assessment <span> (Details )</span> </p> <p> <b> outputParameters</b> : id: outputParameters1</p> </div> </text> <contained> 
    <Parameters> 
      <id value="outputParameters1"/> 
      <parameter> 
        <name value="score"/> 
        <valueDecimal value="7"/> 
      </parameter> 
      <parameter> 
        <name value="item-assessed"/> 
    <valueCodeableConcept> 
      <coding> 
      <system value="http://www.ama-assn.org/go/cpt"/> 
      <code value="70450"/> 
      <display value="CT, head, wo iv contrast"/> 
      </coding> 
    </valueCodeableConcept> 
      </parameter> 
      <parameter> 
        <name value="device"/> 
        <valueReference> 
          <reference value="Device/software"/> 
        </valueReference> 
      </parameter> 
      <parameter> 
        <name value="guideline-followed"/> 
        <valueUri value="http://someguidelineprovider.org/radiology-appropriateness-guidelines.html"/> 
      </parameter> 
    </Parameters> 
  </contained> 
  <requestId value="guidanceRequest1"/> 
  <identifier> 
    <system value="http://example.org"/> 
    <value value="guidanceResponse1"/> 
  </identifier> 
  <module> 
    <reference value="ServiceDefinition/example"/> 
  </module> 
  <status value="success"/> 
  <subject> 
    <reference value="Patient/example"/> 
  </subject> 
  <context> 
    <reference value="Encounter/example"/> 
  </context> 
  <occurrenceDateTime value="2017-03-10T16:02:00Z"/> 
  <performer> 
    <reference value="Device/software"/> 
  </performer> 
  <reasonCodeableConcept> 
    <text value="Guideline Appropriate Ordering Assessment"/> 
  </reasonCodeableConcept> 
  <outputParameters> 
    <reference value="#outputParameters1"/> 
  </outputParameters> 
</GuidanceResponse> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.