FHIR Release 3 (STU)

This page is part of the FHIR Specification (v3.0.2: STU 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R3

Device-example-udi2.xml

Orders and Observations Work GroupMaturity Level: N/ABallot Status: InformativeCompartments: Device

Raw XML (canonical form)

Jump past Narrative

Implantable device/UDI example ICCBBA Format (id = "example-udi2")

<Device xmlns="http://hl7.org/fhir">
  <id value="example-udi2"/> 
  <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative with Details</b> </p> <p> <b> id</b> : example-udi2</p> <h3> Udis</h3> <table> <tr> <td> -</td> <td> <b> DeviceIdentifier</b> </td> <td> <b> Name</b> </td> <td> <b> Jurisdiction</b> </td> <td> <b> Issuer</b> </td> </tr> <tr> <td> *</td> <td> A9999XYZ100T0474</td> <td> Bone,Putty Demineralized</td> <td> <a> http://hl7.org/fhir/NamingSystem/fda-udi</a> </td> <td> <a> http://hl7.org/fhir/NamingSystem/iccbba-other</a> </td> </tr> </table> <p> <b> status</b> : inactive</p> <p> <b> manufacturer</b> : Acme Devices, Inc</p> <p> <b> manufactureDate</b> : 01/02/2013</p> <p> <b> expirationDate</b> : 01/02/2014</p> <p> <b> patient</b> : <a> Patient/example</a> </p> </div> </text> <extension url="http://hl7.org/fhir/StructureDefinition/device-din">
    <!--    from Element: extension    -->
    <valueIdentifier> 
      <system value="http://hl7.org/fhir/NamingSystem/iccbba-din"/> 
      <!--     If the content is from an ICCBBA-encoded UDI, this is the URI to use for the system
          -->
      <value value="A99971312345600"/> 
      <!--     this is the donation identification number    -->
    </valueIdentifier> 
  </extension> 
  <udi> 
    <!--     The Device Identifier (DI) here so you can look up - in this case using the GUDID
     database    -->
    <deviceIdentifier value="A9999XYZ100T0474"/> 
    <name value="Bone,Putty Demineralized"/> 
    <!--    This is  US FDA example    -->
    <jurisdiction value="http://hl7.org/fhir/NamingSystem/fda-udi"/> 
    <!--     If the content is from an ICCBBA-encoded UDI, this is the URI to use for the system
        -->
    <issuer value="http://hl7.org/fhir/NamingSystem/iccbba-other"/> 
  </udi> 
  <status value="inactive"/> 
  <manufacturer value="Acme Devices, Inc"/> 
  <manufactureDate value="2013-02-01"/> 
  <!--     013032 = this is the manufacturing date expressed in YYYDDD (three digit year, three
   digit day number)   -->
  <expirationDate value="2014-02-01"/> 
  <!--   014032 = this is the expiration date expressed in YYYDDD (three digit year, three digit
   day number)   -->
  <patient> 
    <reference value="Patient/example"/> 
  </patient> 
</Device> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.