This page is part of the FHIR Specification (v3.0.2: STU 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Vocabulary Work Group | Maturity Level: N/A | Ballot Status: Informative |
Definition for Code System AllergyIntoleranceCriticality
<CodeSystem xmlns="http://hl7.org/fhir"> <id value="allergy-intolerance-criticality"/> <meta> <lastUpdated value="2019-10-24T11:53:00+11:00"/> </meta> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"> <h2> AllergyIntoleranceCriticality</h2> <div> <p> Estimate of the potential clinical harm, or seriousness, of a reaction to an identified substance.</p> </div> <p> This code system http://hl7.org/fhir/allergy-intolerance-criticality defines the following codes:</p> <table class="codes"> <tr> <td> <b> Code</b> </td> <td> <b> Display</b> </td> <td> <b> Definition</b> </td> </tr> <tr> <td> low <a name="allergy-intolerance-criticality-low"> </a> </td> <td> Low Risk</td> <td> Worst case result of a future exposure is not assessed to be life-threatening or having high potential for organ system failure.</td> </tr> <tr> <td> high <a name="allergy-intolerance-criticality-high"> </a> </td> <td> High Risk</td> <td> Worst case result of a future exposure is assessed to be life-threatening or having high potential for organ system failure.</td> </tr> <tr> <td> unable-to-assess <a name="allergy-intolerance-criticality-unable-to-assess"> </a> </td> <td> Unable to Assess Risk</td> <td> Unable to assess the worst case result of a future exposure.</td> </tr> </table> </div> </text> <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-ballot-status"> <valueString value="Informative"/> </extension> <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm"> <valueInteger value="3"/> </extension> <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg"> <valueCode value="pc"/> </extension> <url value="http://hl7.org/fhir/allergy-intolerance-criticality"/> <identifier> <system value="urn:ietf:rfc:3986"/> <value value="urn:oid:2.16.840.1.113883.4.642.1.120"/> </identifier> <version value="3.0.2"/> <name value="AllergyIntoleranceCriticality"/> <status value="draft"/> <experimental value="false"/> <date value="2019-10-24T11:53:00+11:00"/> <publisher value="HL7 (FHIR Project)"/> <contact> <telecom> <system value="url"/> <value value="http://hl7.org/fhir"/> </telecom> <telecom> <system value="email"/> <value value="fhir@lists.hl7.org"/> </telecom> </contact> <description value="Estimate of the potential clinical harm, or seriousness, of a reaction to an identified substance."/> <caseSensitive value="true"/> <valueSet value="http://hl7.org/fhir/ValueSet/allergy-intolerance-criticality"/> <content value="complete"/> <concept> <code value="low"/> <display value="Low Risk"/> <definition value="Worst case result of a future exposure is not assessed to be life-threatening or having high potential for organ system failure."/> </concept> <concept> <code value="high"/> <display value="High Risk"/> <definition value="Worst case result of a future exposure is assessed to be life-threatening or having high potential for organ system failure."/> </concept> <concept> <code value="unable-to-assess"/> <display value="Unable to Assess Risk"/> <definition value="Unable to assess the worst case result of a future exposure."/> </concept> </CodeSystem>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.