This page is part of the FHIR Specification (v3.0.2: STU 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Security Work Group | Maturity Level: N/A | Ballot Status: Informative | Compartments: Device, Patient, Practitioner |
RESTful vread Operation (id = "example-rest")
<AuditEvent xmlns="http://hl7.org/fhir"> <id value="example-rest"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative with Details</b> </p> <p> <b> id</b> : example-rest</p> <p> <b> type</b> : Restful Operation (Details: http://hl7.org/fhir/audit-event-type code rest = 'RESTful Operation', stated as 'Restful Operation')</p> <p> <b> subtype</b> : vread (Details: http://hl7.org/fhir/restful-interaction code vread = 'vread', stated as 'vread')</p> <p> <b> action</b> : R</p> <p> <b> recorded</b> : 20/06/2013 11:42:24 PM</p> <p> <b> outcome</b> : 0</p> <blockquote> <p> <b> agent</b> </p> <p> <b> userId</b> : 95</p> <p> <b> altId</b> : 601847123</p> <p> <b> name</b> : Grahame Grieve</p> <p> <b> requestor</b> : true</p> </blockquote> <blockquote> <p> <b> agent</b> </p> <p> <b> role</b> : Source Role ID <span> (Details : {DICOM code '110153' = 'Source Role ID', given as 'Source Role ID'})</span> </p> <p> <b> userId</b> : 2.16.840.1.113883.4.2|2.16.840.1.113883.4.2</p> <p> <b> altId</b> : 6580</p> <p> <b> requestor</b> : false</p> <h3> Networks</h3> <table> <tr> <td> -</td> <td> <b> Address</b> </td> <td> <b> Type</b> </td> </tr> <tr> <td> *</td> <td> Workstation1.ehr.familyclinic.com</td> <td> 1</td> </tr> </table> </blockquote> <h3> Sources</h3> <table> <tr> <td> -</td> <td> <b> Site</b> </td> <td> <b> Identifier</b> </td> <td> <b> Type</b> </td> </tr> <tr> <td> *</td> <td> Cloud</td> <td> hl7connect.healthintersections.com.au</td> <td> Web Server (Details: http://hl7.org/fhir/security-source-type code 3 = 'Web Server', stated as 'Web Server')</td> </tr> </table> <h3> Entities</h3> <table> <tr> <td> -</td> <td> <b> Reference</b> </td> <td> <b> Type</b> </td> <td> <b> Lifecycle</b> </td> </tr> <tr> <td> *</td> <td> <a> Patient/example/_history/1</a> </td> <td> System Object (Details: http://hl7.org/fhir/object-type code 2 = '2', stated as 'System Object')</td> <td> Access / Use (Details: http://hl7.org/fhir/dicom-audit-lifecycle code 6 = 'Access / Use', stated as 'Access / Use')</td> </tr> </table> </div> </text> <type> <system value="http://hl7.org/fhir/audit-event-type"/> <code value="rest"/> <display value="Restful Operation"/> </type> <subtype> <system value="http://hl7.org/fhir/restful-interaction"/> <code value="vread"/> <display value="vread"/> </subtype> <action value="R"/> <recorded value="2013-06-20T23:42:24Z"/> <outcome value="0"/> <agent> <userId> <value value="95"/> </userId> <altId value="601847123"/> <name value="Grahame Grieve"/> <requestor value="true"/> </agent> <agent> <!-- Source active participant, the software making the . AlternativeUserId - Process ID --> <role> <coding> <system value="http://dicom.nema.org/resources/ontology/DCM"/> <code value="110153"/> <display value="Source Role ID"/> </coding> </role> <userId> <value value="2.16.840.1.113883.4.2|2.16.840.1.113883.4.2"/> </userId> <altId value="6580"/> <requestor value="false"/> <network> <address value="Workstation1.ehr.familyclinic.com"/> <type value="1"/> </network> </agent> <source> <site value="Cloud"/> <identifier> <value value="hl7connect.healthintersections.com.au"/> </identifier> <type> <system value="http://hl7.org/fhir/security-source-type"/> <code value="3"/> <display value="Web Server"/> </type> </source> <entity> <reference> <reference value="Patient/example/_history/1"/> </reference> <type> <system value="http://hl7.org/fhir/object-type"/> <code value="2"/> <display value="System Object"/> </type> <lifecycle> <system value="http://hl7.org/fhir/dicom-audit-lifecycle"/> <code value="6"/> <display value="Access / Use"/> </lifecycle> </entity> </AuditEvent>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.