This page is part of the FHIR Specification (v1.0.2: DSTU 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Specimen Reject Example
{ "resourceType": "Observation", "id": "unsat", "text": { "fhir_comments": [ " urn:oid:2.16.840.1.113883.4.642.1.7 ", " 2.16.840.1.113883.4.642.1.118 " ], "status": "generated", "div": "<div><p><b>Generated Narrative with Details</b></p><p><b>id</b>: unsat</p><p><b>identifier</b>: 6323 (OFFICIAL)</p><p><b>status</b>: cancelled</p><p><b>code</b>: Glucose [Moles/volume] in Blood <span>(Details : {LOINC code '15074-8' = 'Glucose [Moles/volume] in Blood', given as 'Glucose [Moles/volume] in Blood'})</span></p><p><b>subject</b>: <a>P. van de Heuvel</a></p><p><b>effective</b>: 02/04/2013 9:30:10 AM --> 05/04/2013 9:30:10 AM</p><p><b>issued</b>: 03/04/2013 3:30:10 PM</p><p><b>performer</b>: <a>A. Langeveld</a></p><p><b>dataAbsentReason</b>: Specimen unsatisfactory for evaluation <span>(Details : {SNOMED CT code '125154007' = '125154007', given as 'Specimen unsatisfactory for evaluation'})</span></p><p><b>comments</b>: Tube broken in transit and sample leaked</p><h3>ReferenceRanges</h3><table><tr><td>-</td><td><b>Low</b></td><td><b>High</b></td></tr><tr><td>*</td><td>3.1 mmol/l<span> (Details: http://unitsofmeasure.org code mmol/L = '??')</span></td><td>6.2 mmol/l<span> (Details: http://unitsofmeasure.org code mmol/L = '??')</span></td></tr></table></div>" }, "identifier": [ { "use": "official", "system": "http://www.bmc.nl/zorgportal/identifiers/observations", "value": "6323" } ], "status": "cancelled", "code": { "coding": [ { "system": "http://loinc.org", "code": "15074-8", "display": "Glucose [Moles/volume] in Blood" } ] }, "subject": { "reference": "Patient/f001", "display": "P. van de Heuvel" }, "effectivePeriod": { "start": "2013-04-02T09:30:10+01:00", "end": "2013-04-05T09:30:10+01:00" }, "issued": "2013-04-03T15:30:10+01:00", "performer": [ { "reference": "Practitioner/f005", "display": "A. Langeveld" } ], "dataAbsentReason": { "coding": [ { "system": "http://snomed.info/sct", "code": "125154007", "display": "Specimen unsatisfactory for evaluation" } ] }, "comments": "Tube broken in transit and sample leaked", "referenceRange": [ { "low": { "value": 3.1, "unit": "mmol/l", "system": "http://unitsofmeasure.org", "code": "mmol/L" }, "high": { "value": 6.2, "unit": "mmol/l", "system": "http://unitsofmeasure.org", "code": "mmol/L" } } ] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.