DSTU2 Ballot Source

This page is part of the FHIR Specification (v0.5.0: DSTU 2 Ballot 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Observation-example-bloodpressure

This is the narrative for the resource. See also the XML or JSON format.

Sept 17, 2012: Systolic Blood pressure 107/60 mmHg (low)

Generated Narrative with Details

text:

code: Blood pressure systolic & diastolic (Details : {LOINC code '55284-4' = 'Blood pressure systolic and diastolic', given as 'Blood pressure systolic & diastolic'})

interpretation: low (Details : {http://hl7.org/fhir/v2/0078 code 'L' = 'Below low normal', given as 'Below low normal'})

applies: Sep 17, 2012

status: FINAL

reliability: OK

identifier: urn:uuid:187e0c12-8dd2-67e2-99b2-bf273c878281

subject: Generated Summary: Extensions: todo; MRN = 12345 (USUAL); Peter James Chalmers (OFFICIAL), Jim ; -unknown-(HOME), ph: (03) 5555 6473(WORK); MALE; birthDate: Dec 25, 1974; active

performer: Generated Summary: 23; Adam Careful

related

type: HASCOMPONENT

target: http://acme.org/ehr/observations/34252345234-s

related

type: HASCOMPONENT

target: http://acme.org/ehr/observations/34252345234-d


Sept 17, 2012: Systolic Blood pressure 107 mmHg (low)

Generated Narrative with Details

text:

code: Systolic blood pressure (Details : {LOINC code '8480-6' = 'Systolic blood pressure', given as 'Systolic blood pressure'}; {SNOMED CT code '271649006' = 'Systolic blood pressure', given as 'Systolic blood pressure'}; {http://acme.org/devices/clinical-codes code 'bp-s' = 'bp-s', given as 'Systolic Blood pressure'})

value: 107 mm[Hg]

status: FINAL

reliability: OK

subject: Generated Summary: Extensions: todo; MRN = 12345 (USUAL); Peter James Chalmers (OFFICIAL), Jim ; -unknown-(HOME), ph: (03) 5555 6473(WORK); MALE; birthDate: Dec 25, 1974; active


Sept 17, 2012: Diastolic Blood pressure 60 mmHg (low)

Generated Narrative with Details

text:

code: Diastolic blood pressure (Details : {LOINC code '8462-4' = 'Diastolic blood pressure', given as 'Diastolic blood pressure'})

value: 60 mm[Hg]

status: FINAL

reliability: OK

subject: Generated Summary: Extensions: todo; MRN = 12345 (USUAL); Peter James Chalmers (OFFICIAL), Jim ; -unknown-(HOME), ph: (03) 5555 6473(WORK); MALE; birthDate: Dec 25, 1974; active


 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.