This page is part of the FHIR Specification (v0.5.0: DSTU 2 Ballot 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
USLab Other (string) Observation Profile Example: S.aureus (id = "uslab-example3")
<Observation xmlns="http://hl7.org/fhir"> <id value="uslab-example3"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><!-- Snipped for brevity --></div> </text><!-- FHIR build is generating the narratives <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"> <ul> <li>file: obs-uslab-example3.xml</li> <li>id: uslab-example3</li> <li>Name: USLab Observation Example3</li> <li>Description: USLab Other (String) Observation Profile Canonical Example: S aureus</li> </ul> </div> </text> --><!-- extension for specimen reject goes here - not for this use case <extension url="http://hl7.org/fhir/StructureDefinition/uslabspecimenrejectreason"> <valueCodeableConcept> <coding> <system value="http://hl7.org/fhir/v2/0490"/> <code value="EX"/> <display value="Expired"/> </coding> </valueCodeableConcept> </extension> --><!-- extension for observation kind goes here --> <extension url="http://hl7.org/fhir/StructureDefinition/uslabobservationkind"> <valueCode value="result"/> </extension><!-- EH : The local and LOINC test codes go here --> <code><!-- EH: LOINC code goes here --> <coding> <system value="http://loinc.org"/> <code value="6463-4"/> <display value="Bacteria identified in Unspecified specimen by Culture"/> </coding><!-- EH: LOCAL code goes here --> <coding> <system value="urn:oid:2.16.840.1.113883.3.72.5.24"/> <code value="MSCBACT"/> <display value="Misc Culture"/> </coding> <text value="Miscellaneous Culture"/> </code><!-- EH : The text result here --> <valueString value="Moderate Growth of gram-positive cocci bacteria"/><!-- eH dataabsent reason would go here if valueQuantity was empty e.g.: <dataAbsentReason value="error"/> --> <interpretation> <coding> <system value="http://hl7.org/fhir/v2/0078"/> <code value="A"/> </coding> </interpretation> <appliesDateTime value="2014-12-05"/><!-- EH: Showing dateTime to ss with TZO although only needed to Day --> <issued value="2014-12-06T15:42:15-08:00"/> <status value="final"/> <identifier> <use value="official"/> <type> <text value="lab test result ID"/> </type> <system value="http://lis.acmelabs.org/identifiers/labtestresult"/> <value value="3456"/> </identifier> <subject> <reference value="Patient/uslab-example1"/> <display value="Todd Lerr"/> </subject> <specimen> <reference value="Specimen/uslab-example1"/> <display value="Blood sample"/> </specimen> <performer> <reference value="Practitioner/uslab-example1"/> <display value="Dr Leonard T Bloodraw Jr"/> </performer> </Observation>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.