ValueSet: R5V3ObservationInterpretationExceptionsForR4B

Official URL: http://hl7.org/fhir/uv/xver/ValueSet/R5-v3-ObservationInterpretationExceptions-for-R4B Version: 0.1.0
Standards status: Trial-use Maturity Level: 0 Computable Name: R5V3ObservationInterpretationExceptionsForR4B

This cross-version ValueSet represents content from http://terminology.hl7.org/ValueSet/v3-ObservationInterpretationExceptions|2.0.0 for use in FHIR R4B.

This value set is part of the cross-version definitions generated to enable use of the value set http://terminology.hl7.org/ValueSet/v3-ObservationInterpretationExceptions|2.0.0 as defined in FHIR R5 in FHIR R4B.

The source value set is bound to the following FHIR R5 elements:

Note that all concepts are included in this cross-version definition because no concepts have compatible representations

Following are the generation technical comments:

FHIR ValueSet http://terminology.hl7.org/ValueSet/v3-ObservationInterpretationExceptions|2.0.0, defined in FHIR R5 does not have any mapping to FHIR R4B

References

This value set is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)

Logical Definition (CLD)

  • Include these codes as defined in http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation version 📍2.1.0
    CodeDisplayDefinition
    <Off scale lowThe result is below the minimum detection limit (the test procedure or equipment is the limiting factor).

    Synonyms: Below analytical limit, low off scale.
    >Off scale highThe result is above the maximum quantifiable limit (the test procedure or equipment is the limiting factor).

    Synonyms: Above analytical limit, high off scale.
    ACAnti-complementary substances presentA valid result cannot be obtained for the specified component / analyte due to the presence of anti-complementary substances in the sample.

    ***Deprecation Comment:*** This code is being deprecated to match the status in V2 Table 0078 "Interpretation Codes.
    IEInsufficient evidenceThere is insufficient evidence that the species in question is a good target for therapy with the drug. A categorical interpretation is not possible.

    \[Note: A MIC with "IE" and/or a comment may be reported (without an accompanying S, I or R-categorization).\]
    QCFQuality control failureA result cannot be considered valid for the specified component / analyte or organism due to failure in the quality control testing component.

    ***Deprecation Comment:*** This code is being deprecated to match the status in V2 Table 0078 "Interpretation Codes.
    TOXCytotoxic substance presentA valid result cannot be obtained for the specified organism or cell line due to the presence of cytotoxic substances in the sample or culture.

    ***Deprecation Comment:*** This code is being deprecated to match the status in V2 Table 0078 "Interpretation Codes.

 

Expansion

This value set expansion contains 6 concepts.

SystemVersionCodeDisplayDefinitionJSONXML
http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation2.1.0  <Off scale low

The result is below the minimum detection limit (the test procedure or equipment is the limiting factor).

Synonyms: Below analytical limit, low off scale.

http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation2.1.0  >Off scale high

The result is above the maximum quantifiable limit (the test procedure or equipment is the limiting factor).

Synonyms: Above analytical limit, high off scale.

http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation2.1.0  ACAnti-complementary substances present

A valid result cannot be obtained for the specified component / analyte due to the presence of anti-complementary substances in the sample.

Deprecation Comment: This code is being deprecated to match the status in V2 Table 0078 "Interpretation Codes.

http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation2.1.0  IEInsufficient evidence

There is insufficient evidence that the species in question is a good target for therapy with the drug. A categorical interpretation is not possible.

[Note: A MIC with "IE" and/or a comment may be reported (without an accompanying S, I or R-categorization).]

http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation2.1.0  QCFQuality control failure

A result cannot be considered valid for the specified component / analyte or organism due to failure in the quality control testing component.

Deprecation Comment: This code is being deprecated to match the status in V2 Table 0078 "Interpretation Codes.

http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation2.1.0  TOXCytotoxic substance present

A valid result cannot be obtained for the specified organism or cell line due to the presence of cytotoxic substances in the sample or culture.

Deprecation Comment: This code is being deprecated to match the status in V2 Table 0078 "Interpretation Codes.


Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code