Extensions for Using Data Elements from FHIR R5 in FHIR R4 - Downloaded Version null See the Directory of published versions
The FHIR R5 resource is represented in FHIR R4 via the ImagingStudy resource.
Note that there is a profile defined to simplify use of this cross-version resource representation:Profile: ImagingStudy
A computable version of the following element information is available in: R5ImagingStudyElementMapToR4
| Source Element (FHIR R5) | Target(s) | Comments |
|---|---|---|
ImagingStudy |
||
ImagingStudy.meta |
ImagingStudy.meta | Element ImagingStudy.meta is mapped to FHIR R4 element ImagingStudy.meta as Equivalent. |
ImagingStudy.implicitRules |
ImagingStudy.implicitRules | Element ImagingStudy.implicitRules is mapped to FHIR R4 element ImagingStudy.implicitRules as Equivalent. |
ImagingStudy.language |
ImagingStudy.language | Element ImagingStudy.language is mapped to FHIR R4 element ImagingStudy.language as Equivalent. |
ImagingStudy.text |
ImagingStudy.text | Element ImagingStudy.text is mapped to FHIR R4 element ImagingStudy.text as Equivalent. |
ImagingStudy.contained |
ImagingStudy.contained | Element ImagingStudy.contained is mapped to FHIR R4 element ImagingStudy.contained as Equivalent. |
ImagingStudy.identifier |
ImagingStudy.identifier | Element ImagingStudy.identifier is mapped to FHIR R4 element ImagingStudy.identifier as Equivalent. |
ImagingStudy.status |
ImagingStudy.status | Element ImagingStudy.status is mapped to FHIR R4 element ImagingStudy.status as Equivalent. |
ImagingStudy.modality |
ImagingStudy.modality Extension: ExtensionImagingStudy_Modality |
Element ImagingStudy.modality is mapped to FHIR R4 element ImagingStudy.modality as SourceIsBroaderThanTarget.The mappings for ImagingStudy.modality do not cover the following types: CodeableConcept.The mappings for ImagingStudy.modality do not cover the following types based on type expansion: text. |
ImagingStudy.subject |
ImagingStudy.subject | Element ImagingStudy.subject is mapped to FHIR R4 element ImagingStudy.subject as Equivalent. |
ImagingStudy.encounter |
ImagingStudy.encounter | Element ImagingStudy.encounter is mapped to FHIR R4 element ImagingStudy.encounter as Equivalent. |
ImagingStudy.started |
ImagingStudy.started | Element ImagingStudy.started is mapped to FHIR R4 element ImagingStudy.started as Equivalent. |
ImagingStudy.basedOn |
ImagingStudy.basedOn | Element ImagingStudy.basedOn is mapped to FHIR R4 element ImagingStudy.basedOn as Equivalent. |
ImagingStudy.partOf |
Extension: ExtensionImagingStudy_PartOf | Element ImagingStudy.partOf has a context of ImagingStudy based on following the parent source element upwards and mapping to ImagingStudy.Element ImagingStudy.partOf has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
ImagingStudy.referrer |
ImagingStudy.referrer | Element ImagingStudy.referrer is mapped to FHIR R4 element ImagingStudy.referrer as Equivalent. |
ImagingStudy.endpoint |
ImagingStudy.endpoint | Element ImagingStudy.endpoint is mapped to FHIR R4 element ImagingStudy.endpoint as Equivalent. |
ImagingStudy.numberOfSeries |
ImagingStudy.numberOfSeries | Element ImagingStudy.numberOfSeries is mapped to FHIR R4 element ImagingStudy.numberOfSeries as Equivalent. |
ImagingStudy.numberOfInstances |
ImagingStudy.numberOfInstances | Element ImagingStudy.numberOfInstances is mapped to FHIR R4 element ImagingStudy.numberOfInstances as Equivalent. |
ImagingStudy.procedure |
ImagingStudy.procedureCode ImagingStudy.procedureReference |
Element ImagingStudy.procedure is mapped to FHIR R4 element ImagingStudy.procedureReference as SourceIsBroaderThanTarget.Element ImagingStudy.procedure is mapped to FHIR R4 element ImagingStudy.procedureCode as SourceIsBroaderThanTarget. |
ImagingStudy.location |
ImagingStudy.location | Element ImagingStudy.location is mapped to FHIR R4 element ImagingStudy.location as Equivalent. |
ImagingStudy.reason |
ImagingStudy.reasonCode ImagingStudy.reasonReference Extension: ExtensionImagingStudy_Reason |
Element ImagingStudy.reason is mapped to FHIR R4 element ImagingStudy.reasonCode as SourceIsBroaderThanTarget.Element ImagingStudy.reason is mapped to FHIR R4 element ImagingStudy.reasonReference as SourceIsBroaderThanTarget.The mappings for ImagingStudy.reason do not cover the following types: CodeableReference. |
ImagingStudy.note |
ImagingStudy.note | Element ImagingStudy.note is mapped to FHIR R4 element ImagingStudy.note as Equivalent. |
ImagingStudy.description |
ImagingStudy.description | Element ImagingStudy.description is mapped to FHIR R4 element ImagingStudy.description as Equivalent. |
ImagingStudy.series |
ImagingStudy.series | Element ImagingStudy.series is mapped to FHIR R4 element ImagingStudy.series as Equivalent. |
ImagingStudy.series.uid |
ImagingStudy.series.uid | Element ImagingStudy.series.uid is mapped to FHIR R4 element ImagingStudy.series.uid as Equivalent. |
ImagingStudy.series.number |
ImagingStudy.series.number | Element ImagingStudy.series.number is mapped to FHIR R4 element ImagingStudy.series.number as Equivalent. |
ImagingStudy.series.modality |
ImagingStudy.series.modality Extension: ExtensionImagingStudy_Series_Modality |
Element ImagingStudy.series.modality is mapped to FHIR R4 element ImagingStudy.series.modality as SourceIsBroaderThanTarget.The mappings for ImagingStudy.series.modality do not cover the following types: CodeableConcept.The mappings for ImagingStudy.series.modality do not cover the following types based on type expansion: text. |
ImagingStudy.series.description |
ImagingStudy.series.description | Element ImagingStudy.series.description is mapped to FHIR R4 element ImagingStudy.series.description as Equivalent. |
ImagingStudy.series.numberOfInstances |
ImagingStudy.series.numberOfInstances | Element ImagingStudy.series.numberOfInstances is mapped to FHIR R4 element ImagingStudy.series.numberOfInstances as Equivalent. |
ImagingStudy.series.endpoint |
ImagingStudy.series.endpoint | Element ImagingStudy.series.endpoint is mapped to FHIR R4 element ImagingStudy.series.endpoint as Equivalent. |
ImagingStudy.series.bodySite |
ImagingStudy.series.bodySite Extension: ExtensionImagingStudy_Series_BodySite |
Element ImagingStudy.series.bodySite is mapped to FHIR R4 element ImagingStudy.series.bodySite as SourceIsBroaderThanTarget.The mappings for ImagingStudy.series.bodySite do not cover the following types: CodeableReference.The mappings for ImagingStudy.series.bodySite do not cover the following types based on type expansion: concept, reference. |
ImagingStudy.series.laterality |
ImagingStudy.series.laterality Extension: ExtensionImagingStudy_Series_Laterality |
Element ImagingStudy.series.laterality is mapped to FHIR R4 element ImagingStudy.series.laterality as SourceIsBroaderThanTarget.The mappings for ImagingStudy.series.laterality do not cover the following types: CodeableConcept.The mappings for ImagingStudy.series.laterality do not cover the following types based on type expansion: text. |
ImagingStudy.series.specimen |
ImagingStudy.series.specimen | Element ImagingStudy.series.specimen is mapped to FHIR R4 element ImagingStudy.series.specimen as Equivalent. |
ImagingStudy.series.started |
ImagingStudy.series.started | Element ImagingStudy.series.started is mapped to FHIR R4 element ImagingStudy.series.started as Equivalent. |
ImagingStudy.series.performer |
ImagingStudy.series.performer | Element ImagingStudy.series.performer is mapped to FHIR R4 element ImagingStudy.series.performer as Equivalent. |
ImagingStudy.series.performer.function |
ImagingStudy.series.performer.function | Element ImagingStudy.series.performer.function is mapped to FHIR R4 element ImagingStudy.series.performer.function as Equivalent. |
ImagingStudy.series.performer.actor |
ImagingStudy.series.performer.actor Standard Extension: alternate-reference |
Element ImagingStudy.series.performer.actor is mapped to FHIR R4 element ImagingStudy.series.performer.actor as SourceIsBroaderThanTarget.The standard extension alternate-reference has been mapped as the representation of FHIR R5 element ImagingStudy.series.performer.actor with unmapped reference targets: HealthcareService. |
ImagingStudy.series.instance |
ImagingStudy.series.instance | Element ImagingStudy.series.instance is mapped to FHIR R4 element ImagingStudy.series.instance as Equivalent. |
ImagingStudy.series.instance.uid |
ImagingStudy.series.instance.uid | Element ImagingStudy.series.instance.uid is mapped to FHIR R4 element ImagingStudy.series.instance.uid as Equivalent. |
ImagingStudy.series.instance.sopClass |
ImagingStudy.series.instance.sopClass | Element ImagingStudy.series.instance.sopClass is mapped to FHIR R4 element ImagingStudy.series.instance.sopClass as Equivalent. |
ImagingStudy.series.instance.number |
ImagingStudy.series.instance.number | Element ImagingStudy.series.instance.number is mapped to FHIR R4 element ImagingStudy.series.instance.number as Equivalent. |
ImagingStudy.series.instance.title |
ImagingStudy.series.instance.title | Element ImagingStudy.series.instance.title is mapped to FHIR R4 element ImagingStudy.series.instance.title as Equivalent. |