The FHIR R5 resource is represented in FHIR R4 via the DeviceUseStatement resource.
Note that there is a profile defined to simplify use of this cross-version resource representation:Profile: DeviceUsage-for-DeviceUseStatement
A computable version of the following element information is available in: R5DeviceUsageElementMapToR4
| Source Element (FHIR R5) | Target(s) | Comments |
|---|---|---|
DeviceUsage |
||
DeviceUsage.meta |
DeviceUseStatement.meta | Element DeviceUsage.meta is mapped to FHIR R4 element DeviceUseStatement.meta as Equivalent. |
DeviceUsage.implicitRules |
DeviceUseStatement.implicitRules | Element DeviceUsage.implicitRules is mapped to FHIR R4 element DeviceUseStatement.implicitRules as Equivalent. |
DeviceUsage.language |
DeviceUseStatement.language | Element DeviceUsage.language is mapped to FHIR R4 element DeviceUseStatement.language as Equivalent. |
DeviceUsage.text |
DeviceUseStatement.text | Element DeviceUsage.text is mapped to FHIR R4 element DeviceUseStatement.text as Equivalent. |
DeviceUsage.contained |
DeviceUseStatement.contained | Element DeviceUsage.contained is mapped to FHIR R4 element DeviceUseStatement.contained as Equivalent. |
DeviceUsage.identifier |
DeviceUseStatement.identifier | Element DeviceUsage.identifier is mapped to FHIR R4 element DeviceUseStatement.identifier as Equivalent. |
DeviceUsage.basedOn |
DeviceUseStatement.basedOn | Element DeviceUsage.basedOn is mapped to FHIR R4 element DeviceUseStatement.basedOn as Equivalent. |
DeviceUsage.status |
DeviceUseStatement.status Extension: ExtensionDeviceUsage_Status |
Element DeviceUsage.status is mapped to FHIR R4 element DeviceUseStatement.status as SourceIsBroaderThanTarget.The target context DeviceUseStatement.status is a modifier element, so this extension does not need to be defined as a modifier. |
DeviceUsage.category |
Extension: ExtensionDeviceUsage_Category | Element DeviceUsage.category has a context of DeviceUseStatement based on following the parent source element upwards and mapping to DeviceUseStatement.Element DeviceUsage.category has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
DeviceUsage.patient |
DeviceUseStatement.subject | Element DeviceUsage.patient is mapped to FHIR R4 element DeviceUseStatement.subject as Equivalent. |
DeviceUsage.derivedFrom |
DeviceUseStatement.derivedFrom Standard Extension: alternate-reference |
Element DeviceUsage.derivedFrom is mapped to FHIR R4 element DeviceUseStatement.derivedFrom as SourceIsBroaderThanTarget.The standard extension alternate-reference has been mapped as the representation of FHIR R5 element DeviceUsage.derivedFrom with unmapped reference targets: DocumentReference. |
DeviceUsage.context |
Extension: ExtensionDeviceUsage_Context | Element DeviceUsage.context has a context of DeviceUseStatement based on following the parent source element upwards and mapping to DeviceUseStatement.Element DeviceUsage.context has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
DeviceUsage.timing[x] |
DeviceUseStatement.timing[x] | Element DeviceUsage.timing[x] is mapped to FHIR R4 element DeviceUseStatement.timing[x] as Equivalent.The target context DeviceUseStatement.timing[x] is a choice-type element and cannot directly hold extensions. The context is moved up to parent element DeviceUseStatement. |
DeviceUsage.dateAsserted |
DeviceUseStatement.recordedOn | Element DeviceUsage.dateAsserted is mapped to FHIR R4 element DeviceUseStatement.recordedOn as Equivalent. |
DeviceUsage.usageStatus |
Extension: ExtensionDeviceUsage_UsageStatus | Element DeviceUsage.usageStatus has a context of DeviceUseStatement based on following the parent source element upwards and mapping to DeviceUseStatement.Element DeviceUsage.usageStatus has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
DeviceUsage.usageReason |
Extension: ExtensionDeviceUsage_UsageReason | Element DeviceUsage.usageReason has a context of DeviceUseStatement based on following the parent source element upwards and mapping to DeviceUseStatement.Element DeviceUsage.usageReason has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
DeviceUsage.adherence |
Extension: ExtensionDeviceUsage_Adherence | Element DeviceUsage.adherence has a context of DeviceUseStatement based on following the parent source element upwards and mapping to DeviceUseStatement.Element DeviceUsage.adherence has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
DeviceUsage.adherence.code |
Extension: ExtensionDeviceUsage_Adherence Slice:code | Element DeviceUsage.adherence.code is part of an existing definition because parent element DeviceUsage.adherence requires a cross-version extension.Element DeviceUsage.adherence.code has a context of DeviceUseStatement based on following the parent source element upwards and mapping to DeviceUseStatement.Element DeviceUsage.adherence.code has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
DeviceUsage.adherence.reason |
Extension: ExtensionDeviceUsage_Adherence Slice:reason | Element DeviceUsage.adherence.reason is part of an existing definition because parent element DeviceUsage.adherence requires a cross-version extension.Element DeviceUsage.adherence.reason has a context of DeviceUseStatement based on following the parent source element upwards and mapping to DeviceUseStatement.Element DeviceUsage.adherence.reason has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
DeviceUsage.informationSource |
DeviceUseStatement.source Standard Extension: alternate-reference |
Element DeviceUsage.informationSource is mapped to FHIR R4 element DeviceUseStatement.source as SourceIsBroaderThanTarget.The standard extension alternate-reference has been mapped as the representation of FHIR R5 element DeviceUsage.informationSource with unmapped reference targets: Organization. |
DeviceUsage.device |
DeviceUseStatement.device Extension: ExtensionDeviceUsage_Device |
Element DeviceUsage.device is mapped to FHIR R4 element DeviceUseStatement.device as SourceIsBroaderThanTarget.The mappings for DeviceUsage.device do not cover the following types: CodeableReference.The mappings for DeviceUsage.device do not cover the following types based on type expansion: concept. |
DeviceUsage.reason |
DeviceUseStatement.reasonCode DeviceUseStatement.reasonReference Extension: ExtensionDeviceUsage_Reason |
Element DeviceUsage.reason is mapped to FHIR R4 element DeviceUseStatement.reasonCode as SourceIsBroaderThanTarget.Element DeviceUsage.reason is mapped to FHIR R4 element DeviceUseStatement.reasonReference as SourceIsBroaderThanTarget.The mappings for DeviceUsage.reason do not cover the following types: CodeableReference. |
DeviceUsage.bodySite |
DeviceUseStatement.bodySite Extension: ExtensionDeviceUsage_BodySite |
Element DeviceUsage.bodySite is mapped to FHIR R4 element DeviceUseStatement.bodySite as SourceIsBroaderThanTarget.The mappings for DeviceUsage.bodySite do not cover the following types: CodeableReference.The mappings for DeviceUsage.bodySite do not cover the following types based on type expansion: reference. |
DeviceUsage.note |
DeviceUseStatement.note | Element DeviceUsage.note is mapped to FHIR R4 element DeviceUseStatement.note as Equivalent. |