Extensions for Using Data Elements from FHIR R5 in FHIR R4 - Downloaded Version null See the Directory of published versions
The FHIR R5 resource is represented in FHIR R4 via the Device resource.
Note that there is a profile defined to simplify use of this cross-version resource representation:Profile: Device
A computable version of the following element information is available in: R5DeviceElementMapToR4
| Source Element (FHIR R5) | Target(s) | Comments |
|---|---|---|
Device |
||
Device.meta |
Device.meta | Element Device.meta is mapped to FHIR R4 element Device.meta as Equivalent. |
Device.implicitRules |
Device.implicitRules | Element Device.implicitRules is mapped to FHIR R4 element Device.implicitRules as Equivalent. |
Device.language |
Device.language | Element Device.language is mapped to FHIR R4 element Device.language as Equivalent. |
Device.text |
Device.text | Element Device.text is mapped to FHIR R4 element Device.text as Equivalent. |
Device.contained |
Device.contained | Element Device.contained is mapped to FHIR R4 element Device.contained as Equivalent. |
Device.identifier |
Device.identifier | Element Device.identifier is mapped to FHIR R4 element Device.identifier as Equivalent. |
Device.displayName |
Device.deviceName Extension: ExtensionDevice_DisplayName |
Element Device.displayName is mapped to FHIR R4 element Device.deviceName as RelatedTo.The mappings for Device.displayName do not cover the following types: string.The mappings for Device.displayName do not cover the following types based on type expansion: value. |
Device.definition |
Device.definition Extension: ExtensionDevice_Definition |
Element Device.definition is mapped to FHIR R4 element Device.definition as SourceIsBroaderThanTarget.The mappings for Device.definition do not cover the following types: CodeableReference.The mappings for Device.definition do not cover the following types based on type expansion: concept. |
Device.udiCarrier |
Device.udiCarrier | Element Device.udiCarrier is mapped to FHIR R4 element Device.udiCarrier as Equivalent. |
Device.udiCarrier.deviceIdentifier |
Device.udiCarrier.deviceIdentifier | Element Device.udiCarrier.deviceIdentifier is mapped to FHIR R4 element Device.udiCarrier.deviceIdentifier as Equivalent. |
Device.udiCarrier.issuer |
Device.udiCarrier.issuer | Element Device.udiCarrier.issuer is mapped to FHIR R4 element Device.udiCarrier.issuer as Equivalent. |
Device.udiCarrier.jurisdiction |
Device.udiCarrier.jurisdiction | Element Device.udiCarrier.jurisdiction is mapped to FHIR R4 element Device.udiCarrier.jurisdiction as Equivalent. |
Device.udiCarrier.carrierAIDC |
Device.udiCarrier.carrierAIDC | Element Device.udiCarrier.carrierAIDC is mapped to FHIR R4 element Device.udiCarrier.carrierAIDC as Equivalent. |
Device.udiCarrier.carrierHRF |
Device.udiCarrier.carrierHRF | Element Device.udiCarrier.carrierHRF is mapped to FHIR R4 element Device.udiCarrier.carrierHRF as Equivalent. |
Device.udiCarrier.entryType |
Device.udiCarrier.entryType Extension: ExtensionDevice_UdiCarrier_EntryType |
Element Device.udiCarrier.entryType is mapped to FHIR R4 element Device.udiCarrier.entryType as RelatedTo.The mappings for Device.udiCarrier.entryType do not allow expression of the necessary codes, per the bindings on the source and target. |
Device.status |
Device.status | Element Device.status is mapped to FHIR R4 element Device.status as SourceIsNarrowerThanTarget.The mappings for Device.status do not allow expression of the necessary codes, per the bindings on the source and target. |
Device.availabilityStatus |
Extension: ExtensionDevice_AvailabilityStatus | Element Device.availabilityStatus has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.availabilityStatus has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
Device.biologicalSourceEvent |
Extension: ExtensionDevice_BiologicalSourceEvent | Element Device.biologicalSourceEvent has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.biologicalSourceEvent has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
Device.manufacturer |
Device.manufacturer | Element Device.manufacturer is mapped to FHIR R4 element Device.manufacturer as Equivalent. |
Device.manufactureDate |
Device.manufactureDate | Element Device.manufactureDate is mapped to FHIR R4 element Device.manufactureDate as Equivalent. |
Device.expirationDate |
Device.expirationDate | Element Device.expirationDate is mapped to FHIR R4 element Device.expirationDate as Equivalent. |
Device.lotNumber |
Device.lotNumber | Element Device.lotNumber is mapped to FHIR R4 element Device.lotNumber as Equivalent. |
Device.serialNumber |
Device.serialNumber | Element Device.serialNumber is mapped to FHIR R4 element Device.serialNumber as Equivalent. |
Device.name |
Device.deviceName | Element Device.name is mapped to FHIR R4 element Device.deviceName as Equivalent. |
Device.name.value |
Device.deviceName Device.deviceName.name |
Element Device.name.value is mapped to FHIR R4 element Device.deviceName.name as Equivalent.Element Device.name.value is mapped to FHIR R4 element Device.deviceName as SourceIsNarrowerThanTarget. |
Device.name.type |
Device.deviceName.type | Element Device.name.type is mapped to FHIR R4 element Device.deviceName.type as SourceIsNarrowerThanTarget.The mappings for Device.name.type do not allow expression of the necessary codes, per the bindings on the source and target. |
Device.name.display |
Device.deviceName | Element Device.name.display is mapped to FHIR R4 element Device.deviceName as SourceIsNarrowerThanTarget. |
Device.modelNumber |
Device.modelNumber | Element Device.modelNumber is mapped to FHIR R4 element Device.modelNumber as Equivalent. |
Device.partNumber |
Device.partNumber | Element Device.partNumber is mapped to FHIR R4 element Device.partNumber as Equivalent. |
Device.category |
Extension: ExtensionDevice_Category | Element Device.category has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.category has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
Device.type |
Device.type | Element Device.type is mapped to FHIR R4 element Device.type as SourceIsBroaderThanTarget. |
Device.version |
Device.version | Element Device.version is mapped to FHIR R4 element Device.version as Equivalent. |
Device.version.type |
Device.version.type | Element Device.version.type is mapped to FHIR R4 element Device.version.type as Equivalent. |
Device.version.component |
Device.version.component | Element Device.version.component is mapped to FHIR R4 element Device.version.component as Equivalent. |
Device.version.installDate |
Extension: ExtensionDevice_Version_InstallDate | Element Device.version.installDate has a context of Device.version based on following the parent source element upwards and mapping to Device.Element Device.version.installDate has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
Device.version.value |
Device.version.value | Element Device.version.value is mapped to FHIR R4 element Device.version.value as Equivalent. |
Device.conformsTo |
Device.specialization Standard Extension: device-conformsTo |
Element Device.conformsTo is mapped to FHIR R4 element Device.specialization as Equivalent.An externally-defined extension that has been mapped as the representation of FHIR R5 element Device.conformsTo: http://hl7.org/fhir/StructureDefinition/device-conformsTo. |
Device.conformsTo.category |
Device.specialization | Element Device.conformsTo.category is mapped to FHIR R4 element Device.specialization as SourceIsNarrowerThanTarget. |
Device.conformsTo.specification |
Device.specialization | Element Device.conformsTo.specification is mapped to FHIR R4 element Device.specialization as SourceIsNarrowerThanTarget. |
Device.conformsTo.version |
Extension: ExtensionDevice_ConformsTo_Version | Element Device.conformsTo.version has a context of Device.specialization based on following the parent source element upwards and mapping to Device.Element Device.conformsTo.version has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
Device.property |
Device.property | Element Device.property is mapped to FHIR R4 element Device.property as Equivalent. |
Device.property.type |
Device.property.type | Element Device.property.type is mapped to FHIR R4 element Device.property.type as Equivalent. |
Device.property.value[x] |
Device.property.valueCode Device.property.valueQuantity Extension: ExtensionDevice_Property_Value |
Element Device.property.value[x] is mapped to FHIR R4 element Device.property.valueQuantity as RelatedTo.Element Device.property.value[x] is mapped to FHIR R4 element Device.property.valueCode as RelatedTo.The mappings for Device.property.value[x] do not cover the following types: Attachment, boolean, integer, Range, string. |
Device.mode |
Extension: ExtensionDevice_Mode | Element Device.mode has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.mode has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
Device.cycle |
Extension: ExtensionDevice_Cycle | Element Device.cycle has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.cycle has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
Device.duration |
Extension: ExtensionDevice_Duration | Element Device.duration has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.duration has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
Device.owner |
Device.owner | Element Device.owner is mapped to FHIR R4 element Device.owner as Equivalent. |
Device.contact |
Device.contact | Element Device.contact is mapped to FHIR R4 element Device.contact as Equivalent. |
Device.location |
Device.location | Element Device.location is mapped to FHIR R4 element Device.location as Equivalent. |
Device.url |
Device.url | Element Device.url is mapped to FHIR R4 element Device.url as Equivalent. |
Device.endpoint |
Extension: ExtensionDevice_Endpoint | Element Device.endpoint has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.endpoint has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
Device.gateway |
Extension: ExtensionDevice_Gateway | Element Device.gateway has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.gateway has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
Device.note |
Device.note | Element Device.note is mapped to FHIR R4 element Device.note as Equivalent. |
Device.safety |
Device.safety | Element Device.safety is mapped to FHIR R4 element Device.safety as Equivalent. |
Device.parent |
Device.parent | Element Device.parent is mapped to FHIR R4 element Device.parent as Equivalent. |