Extensions for Using Data Elements from FHIR R5 in FHIR R4
0.1.0 - STU International flag

Extensions for Using Data Elements from FHIR R5 in FHIR R4 - Downloaded Version null See the Directory of published versions

ValueSet: R5V3ActSupplyFulfillmentRefusalReasonForR4

Official URL: http://hl7.org/fhir/uv/xver/ValueSet/R5-v3-ActSupplyFulfillmentRefusalReason-for-R4 Version: 0.1.0
Standards status: Trial-use Maturity Level: 0 Computable Name: R5V3ActSupplyFulfillmentRefusalReasonForR4

This cross-version ValueSet represents content from http://terminology.hl7.org/ValueSet/v3-ActSupplyFulfillmentRefusalReason|2.0.0 for use in FHIR R4.

This value set is part of the cross-version definitions generated to enable use of the value set http://terminology.hl7.org/ValueSet/v3-ActSupplyFulfillmentRefusalReason|2.0.0 as defined in FHIR R5 in FHIR R4.

The source value set is bound to the following FHIR R5 elements:

Note that all concepts are included in this cross-version definition because no concepts have compatible representations

Following are the generation technical comments:

FHIR ValueSet http://terminology.hl7.org/ValueSet/v3-ActSupplyFulfillmentRefusalReason|2.0.0, defined in FHIR R5 does not have any mapping to FHIR R4

References

This value set is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)

Logical Definition (CLD)

  • Include these codes as defined in http://terminology.hl7.org/CodeSystem/v3-ActReason version 📍2.1.0
    CodeDisplayDefinition
    FRR01order stopped**Definition:**The order has been stopped by the prescriber but this fact has not necessarily captured electronically.

    **Example:**A verbal stop, a fax, etc.
    FRR02stale-dated order**Definition:**Order has not been fulfilled within a reasonable amount of time, and may not be current.
    FRR03incomplete data**Definition:**Data needed to safely act on the order which was expected to become available independent of the order is not yet available

    **Example:**Lab results, diagnostic imaging, etc.
    FRR04product unavailable**Definition:**Product not available or manufactured. Cannot supply.
    FRR05ethical/religious**Definition:**The dispenser has ethical, religious or moral objections to fulfilling the order/dispensing the product.
    FRR06unable to provide care**Definition:**Fulfiller not able to provide appropriate care associated with fulfilling the order.

    **Example:**Therapy requires ongoing monitoring by fulfiller and fulfiller will be ending practice, leaving town, unable to schedule necessary time, etc.
    _ActSupplyFulfillmentRefusalReasonActSupplyFulfillmentRefusalReasonIndicates why a fulfiller refused to fulfill a supply order, and considered it important to notify other providers of their decision. E.g. "Suspect fraud", "Possible abuse", "Contraindicated".

    (used when capturing 'refusal to fill' annotations)

 

Expansion

This value set expansion contains 7 concepts.

SystemVersionCodeDisplayDefinitionJSONXML
http://terminology.hl7.org/CodeSystem/v3-ActReason2.1.0  FRR01order stopped

**Definition:**The order has been stopped by the prescriber but this fact has not necessarily captured electronically.

**Example:**A verbal stop, a fax, etc.

http://terminology.hl7.org/CodeSystem/v3-ActReason2.1.0  FRR02stale-dated order

**Definition:**Order has not been fulfilled within a reasonable amount of time, and may not be current.

http://terminology.hl7.org/CodeSystem/v3-ActReason2.1.0  FRR03incomplete data

**Definition:**Data needed to safely act on the order which was expected to become available independent of the order is not yet available

**Example:**Lab results, diagnostic imaging, etc.

http://terminology.hl7.org/CodeSystem/v3-ActReason2.1.0  FRR04product unavailable

**Definition:**Product not available or manufactured. Cannot supply.

http://terminology.hl7.org/CodeSystem/v3-ActReason2.1.0  FRR05ethical/religious

**Definition:**The dispenser has ethical, religious or moral objections to fulfilling the order/dispensing the product.

http://terminology.hl7.org/CodeSystem/v3-ActReason2.1.0  FRR06unable to provide care

**Definition:**Fulfiller not able to provide appropriate care associated with fulfilling the order.

**Example:**Therapy requires ongoing monitoring by fulfiller and fulfiller will be ending practice, leaving town, unable to schedule necessary time, etc.

http://terminology.hl7.org/CodeSystem/v3-ActReason2.1.0  _ActSupplyFulfillmentRefusalReasonActSupplyFulfillmentRefusalReason

Indicates why a fulfiller refused to fulfill a supply order, and considered it important to notify other providers of their decision. E.g. "Suspect fraud", "Possible abuse", "Contraindicated".

(used when capturing 'refusal to fill' annotations)


Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code