FHIR Cross-Version Extensions package for FHIR R4 from FHIR R5 - Version 0.0.1-snapshot-2. See the Directory of published versions
| Official URL: http://hl7.org/fhir/5.0/ValueSet/R5-v2-0951-for-R4 | Version: 0.0.1-snapshot-2 | |||
| Standards status: Informative | Maturity Level: 0 | Computable Name: R5_v2_0951_for_R4 | ||
| This cross-version ValueSet represents concepts from http://terminology.hl7.org/ValueSet/v2-0951 | 2.0.0 for use in FHIR R4. Concepts not present here have direct equivalent mappings crossing all versions from R5 to R4. |
References
This value set is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)
http://terminology.hl7.org/CodeSystem/v2-0951 version 2.1.0| Code | Display | Definition |
| BS | Bank residual specimen | Requests that the specimen should be stored long term |
| CR | Confirm results value | Requests verification of previously reported results |
| FP | Store residual specimen pending follow up | Requests that the specimen should be saved for a short duration until follow up is completed |
| IN | Interpret results | Requests interpretation of previously reported results |
| IR | Review clinically inconsistent results | Requests comparison of previously reported results amongst themselves |
| IT | Incorrect test performed | For process improvement work this code can be used to identify when an incorrect test was performed for the target order |
| OP | Test ordering problem | For process improvement work this code can be used to identify orders and the respective results, where problems occurred during ordering |
| PI | Patient identification problem | For process improvement work this code can be used to identify when a patient identification issue has occurred on the target order |
| SI | Suspected interference | Requests verification of previously reported results due to suspected interference |
| SP | Sampling problem | For process improvement work this code can be used to identify orders, where problems occurred during sample collection |
| TP | Specimen transport problem | For process improvement work this code can be used to identify orders, where problems occurred during sample transport |
| TT | Turnaround time problem | For process improvement work this code can be used to identify results with excessive reporting delay |
| XR | Incorrect results | For process improvement work this code can be used to identify when incorrect result were reported for the target order |
This value set expansion contains 13 concepts.
| Code | System | Display | Definition |
| BS | http://terminology.hl7.org/CodeSystem/v2-0951 | Bank residual specimen | Requests that the specimen should be stored long term |
| CR | http://terminology.hl7.org/CodeSystem/v2-0951 | Confirm results value | Requests verification of previously reported results |
| FP | http://terminology.hl7.org/CodeSystem/v2-0951 | Store residual specimen pending follow up | Requests that the specimen should be saved for a short duration until follow up is completed |
| IN | http://terminology.hl7.org/CodeSystem/v2-0951 | Interpret results | Requests interpretation of previously reported results |
| IR | http://terminology.hl7.org/CodeSystem/v2-0951 | Review clinically inconsistent results | Requests comparison of previously reported results amongst themselves |
| IT | http://terminology.hl7.org/CodeSystem/v2-0951 | Incorrect test performed | For process improvement work this code can be used to identify when an incorrect test was performed for the target order |
| OP | http://terminology.hl7.org/CodeSystem/v2-0951 | Test ordering problem | For process improvement work this code can be used to identify orders and the respective results, where problems occurred during ordering |
| PI | http://terminology.hl7.org/CodeSystem/v2-0951 | Patient identification problem | For process improvement work this code can be used to identify when a patient identification issue has occurred on the target order |
| SI | http://terminology.hl7.org/CodeSystem/v2-0951 | Suspected interference | Requests verification of previously reported results due to suspected interference |
| SP | http://terminology.hl7.org/CodeSystem/v2-0951 | Sampling problem | For process improvement work this code can be used to identify orders, where problems occurred during sample collection |
| TP | http://terminology.hl7.org/CodeSystem/v2-0951 | Specimen transport problem | For process improvement work this code can be used to identify orders, where problems occurred during sample transport |
| TT | http://terminology.hl7.org/CodeSystem/v2-0951 | Turnaround time problem | For process improvement work this code can be used to identify results with excessive reporting delay |
| XR | http://terminology.hl7.org/CodeSystem/v2-0951 | Incorrect results | For process improvement work this code can be used to identify when incorrect result were reported for the target order |
Explanation of the columns that may appear on this page:
| Level | A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies |
| System | The source of the definition of the code (when the value set draws in codes defined elsewhere) |
| Code | The code (used as the code in the resource instance) |
| Display | The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application |
| Definition | An explanation of the meaning of the concept |
| Comments | Additional notes about how to use the code |