FHIR Cross-Version Extensions package for FHIR R4 from FHIR R5 - Version 0.0.1-snapshot-2. See the Directory of published versions
| Official URL: http://hl7.org/fhir/5.0/ValueSet/R5-specimen-role-for-R4 | Version: 0.0.1-snapshot-2 | |||
| Standards status: Informative | Maturity Level: 2 | Responsible: Orders and Observations | Computable Name: R5_specimen_role_for_R4 | |
| This cross-version ValueSet represents concepts from http://hl7.org/fhir/ValueSet/specimen-role | 5.0.0 for use in FHIR R4. Concepts not present here have direct equivalent mappings crossing all versions from R5 to R4. | 
    
References
http://hl7.org/fhir/specimen-role version 5.0.0| Code | Display | Definition | 
| b | Blind Sample | Used to test the validity of the measurement process, where the composition of the sample is unknown except to the person submitting it. | 
| c | Calibrator | Used for initial setting of calibration of the instrument. | 
| e | Electronic QC | Used with manufactured reference providing signals that simulate QC results. | 
| f | Filler Organization Proficiency | Specimen used for testing proficiency of the organization performing the testing (Filler). | 
| o | Operator Proficiency | Specimen used for testing Operator Proficiency. | 
| p | Patient | Used for any patient sample. | 
| q | Control specimen | Used when specimen is the control specimen (either positive or negative). | 
| r | Replicate (of patient sample as a control) | Used when a patient sample is re-run as a control for a repeat test. | 
| v | Verifying Calibrator | Used for periodic calibration checks. | 
This value set expansion contains 9 concepts.
| Code | System | Display | Definition | 
| b | http://hl7.org/fhir/specimen-role | Blind Sample | Used to test the validity of the measurement process, where the composition of the sample is unknown except to the person submitting it. | 
| c | http://hl7.org/fhir/specimen-role | Calibrator | Used for initial setting of calibration of the instrument. | 
| e | http://hl7.org/fhir/specimen-role | Electronic QC | Used with manufactured reference providing signals that simulate QC results. | 
| f | http://hl7.org/fhir/specimen-role | Filler Organization Proficiency | Specimen used for testing proficiency of the organization performing the testing (Filler). | 
| o | http://hl7.org/fhir/specimen-role | Operator Proficiency | Specimen used for testing Operator Proficiency. | 
| p | http://hl7.org/fhir/specimen-role | Patient | Used for any patient sample. | 
| q | http://hl7.org/fhir/specimen-role | Control specimen | Used when specimen is the control specimen (either positive or negative). | 
| r | http://hl7.org/fhir/specimen-role | Replicate (of patient sample as a control) | Used when a patient sample is re-run as a control for a repeat test. | 
| v | http://hl7.org/fhir/specimen-role | Verifying Calibrator | Used for periodic calibration checks. | 
Explanation of the columns that may appear on this page:
| Level | A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies | 
| System | The source of the definition of the code (when the value set draws in codes defined elsewhere) | 
| Code | The code (used as the code in the resource instance) | 
| Display | The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application | 
| Definition | An explanation of the meaning of the concept | 
| Comments | Additional notes about how to use the code |