Extensions for Using Data Elements from FHIR R5 in FHIR STU3
0.1.0 - STU International flag

Extensions for Using Data Elements from FHIR R5 in FHIR STU3 - Downloaded Version null See the Directory of published versions

Lookup for Profile_R5_DeviceMetric_R3

Lookup for FHIR R5 DeviceMetric for use in FHIR STU3

The FHIR R5 resource is represented in FHIR STU3 via the DeviceMetric resource.

Note that there is a profile defined to simplify use of this cross-version resource representation:Profile: DeviceMetric

A computable version of the following element information is available in: R5DeviceMetricElementMapToR3

Source Element (FHIR R5) Target(s) Comments
DeviceMetric    
DeviceMetric.meta DeviceMetric.meta Element DeviceMetric.meta is mapped to FHIR STU3 element DeviceMetric.meta as Equivalent.
DeviceMetric.implicitRules DeviceMetric.implicitRules Element DeviceMetric.implicitRules is mapped to FHIR STU3 element DeviceMetric.implicitRules as Equivalent.
DeviceMetric.language DeviceMetric.language Element DeviceMetric.language is mapped to FHIR STU3 element DeviceMetric.language as Equivalent.
DeviceMetric.text DeviceMetric.text Element DeviceMetric.text is mapped to FHIR STU3 element DeviceMetric.text as Equivalent.
DeviceMetric.contained DeviceMetric.contained Element DeviceMetric.contained is mapped to FHIR STU3 element DeviceMetric.contained as SourceIsBroaderThanTarget.
DeviceMetric.identifier DeviceMetric.identifier Element DeviceMetric.identifier is mapped to FHIR STU3 element DeviceMetric.identifier as SourceIsBroaderThanTarget.
DeviceMetric.type DeviceMetric.type Element DeviceMetric.type is mapped to FHIR STU3 element DeviceMetric.type as Equivalent.
DeviceMetric.unit DeviceMetric.unit Element DeviceMetric.unit is mapped to FHIR STU3 element DeviceMetric.unit as Equivalent.
DeviceMetric.device DeviceMetric.parent
DeviceMetric.source
Standard Extension: alternate-reference
Element DeviceMetric.device is mapped to FHIR STU3 element DeviceMetric.source as SourceIsBroaderThanTarget.
Element DeviceMetric.device is mapped to FHIR STU3 element DeviceMetric.parent as SourceIsBroaderThanTarget.
The mappings for DeviceMetric.device do not cover the following types based on type expansion: display, identifier, reference, type.
The standard extension alternate-reference has been mapped as the representation of FHIR R5 element DeviceMetric.device with unmapped reference targets: Device.
DeviceMetric.operationalStatus DeviceMetric.operationalStatus Element DeviceMetric.operationalStatus is mapped to FHIR STU3 element DeviceMetric.operationalStatus as Equivalent.
DeviceMetric.color DeviceMetric.color Element DeviceMetric.color is mapped to FHIR STU3 element DeviceMetric.color as Equivalent.
DeviceMetric.category DeviceMetric.category Element DeviceMetric.category is mapped to FHIR STU3 element DeviceMetric.category as Equivalent.
DeviceMetric.measurementFrequency Extension: ExtensionDeviceMetric_MeasurementFrequency Element DeviceMetric.measurementFrequency has a context of DeviceMetric based on following the parent source element upwards and mapping to DeviceMetric.
Element DeviceMetric.measurementFrequency has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).
DeviceMetric.calibration DeviceMetric.calibration Element DeviceMetric.calibration is mapped to FHIR STU3 element DeviceMetric.calibration as Equivalent.
DeviceMetric.calibration.type DeviceMetric.calibration.type Element DeviceMetric.calibration.type is mapped to FHIR STU3 element DeviceMetric.calibration.type as Equivalent.
DeviceMetric.calibration.state DeviceMetric.calibration.state Element DeviceMetric.calibration.state is mapped to FHIR STU3 element DeviceMetric.calibration.state as Equivalent.
DeviceMetric.calibration.time DeviceMetric.calibration.time Element DeviceMetric.calibration.time is mapped to FHIR STU3 element DeviceMetric.calibration.time as Equivalent.