Extensions for Using Data Elements from FHIR R5 in FHIR STU3 - Downloaded Version null See the Directory of published versions
The FHIR R5 resource is represented in FHIR STU3 via the Basic resource.
Note that there is a profile defined to simplify use of this cross-version resource representation:Profile: DeviceDefinition
A computable version of the following element information is available in: R5DeviceDefinitionElementMapToR3
| Source Element (FHIR R5) | Target(s) | Comments |
|---|---|---|
DeviceDefinition |
||
DeviceDefinition.meta |
Basic.meta | Element matches Basic element path Basic.meta (Resource.meta), use that element instead.Element DeviceDefinition.meta is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.meta has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.implicitRules |
Basic.implicitRules | Element matches Basic element path Basic.implicitRules (Resource.implicitRules), use that element instead.Element DeviceDefinition.implicitRules is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.implicitRules has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.language |
Basic.language | Element matches Basic element path Basic.language (Resource.language), use that element instead.Element DeviceDefinition.language is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.language has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.text |
Basic.text | Element matches Basic element path Basic.text (DomainResource.text), use that element instead.Element DeviceDefinition.text is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.text has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.contained |
Basic.contained | Element matches Basic element path Basic.contained (DomainResource.contained), use that element instead.Element DeviceDefinition.contained is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.contained has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.description |
Standard Extension: artifact-description | Element DeviceDefinition.description is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.description has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).An externally-defined extension that has been mapped as the representation of FHIR R5 element DeviceDefinition.description: http://hl7.org/fhir/StructureDefinition/artifact-description. |
DeviceDefinition.identifier |
Basic.identifier | Element matches Basic element path Basic.identifier (Basic.identifier), use that element instead.Element DeviceDefinition.identifier is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.identifier has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.udiDeviceIdentifier |
Extension: ExtensionDeviceDefinition_UdiDeviceIdentifier | Element DeviceDefinition.udiDeviceIdentifier is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.udiDeviceIdentifier has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.udiDeviceIdentifier.deviceIdentifier |
Extension: ExtensionDeviceDefinition_UdiDeviceIdentifier Slice:deviceIdentifier | Element DeviceDefinition.udiDeviceIdentifier.deviceIdentifier is part of an existing definition because parent element DeviceDefinition.udiDeviceIdentifier requires a cross-version extension.Element DeviceDefinition.udiDeviceIdentifier.deviceIdentifier is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.udiDeviceIdentifier.deviceIdentifier has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.udiDeviceIdentifier.issuer |
Extension: ExtensionDeviceDefinition_UdiDeviceIdentifier Slice:issuer | Element DeviceDefinition.udiDeviceIdentifier.issuer is part of an existing definition because parent element DeviceDefinition.udiDeviceIdentifier requires a cross-version extension.Element DeviceDefinition.udiDeviceIdentifier.issuer is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.udiDeviceIdentifier.issuer has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.udiDeviceIdentifier.jurisdiction |
Extension: ExtensionDeviceDefinition_UdiDeviceIdentifier Slice:jurisdiction | Element DeviceDefinition.udiDeviceIdentifier.jurisdiction is part of an existing definition because parent element DeviceDefinition.udiDeviceIdentifier requires a cross-version extension.Element DeviceDefinition.udiDeviceIdentifier.jurisdiction is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.udiDeviceIdentifier.jurisdiction has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.udiDeviceIdentifier.marketDistribution |
Extension: ExtensionDeviceDefinition_UdiDeviceIdentifier Slice:marketDistribution | Element DeviceDefinition.udiDeviceIdentifier.marketDistribution is part of an existing definition because parent element DeviceDefinition.udiDeviceIdentifier requires a cross-version extension.Element DeviceDefinition.udiDeviceIdentifier.marketDistribution is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.udiDeviceIdentifier.marketDistribution has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.udiDeviceIdentifier.marketDistribution.marketPeriod |
Extension: ExtensionDeviceDefinition_UdiDeviceIdentifier_MarketDistribution Slice:marketPeriod | Element DeviceDefinition.udiDeviceIdentifier.marketDistribution.marketPeriod is part of an existing definition because parent element DeviceDefinition.udiDeviceIdentifier.marketDistribution requires a cross-version extension.Element DeviceDefinition.udiDeviceIdentifier.marketDistribution.marketPeriod is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.udiDeviceIdentifier.marketDistribution.marketPeriod has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.udiDeviceIdentifier.marketDistribution.subJurisdiction |
Extension: ExtensionDeviceDefinition_UdiDeviceIdentifier_MarketDistribution Slice:subJurisdiction | Element DeviceDefinition.udiDeviceIdentifier.marketDistribution.subJurisdiction is part of an existing definition because parent element DeviceDefinition.udiDeviceIdentifier.marketDistribution requires a cross-version extension.Element DeviceDefinition.udiDeviceIdentifier.marketDistribution.subJurisdiction is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.udiDeviceIdentifier.marketDistribution.subJurisdiction has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.regulatoryIdentifier |
Extension: ExtensionDeviceDefinition_RegulatoryIdentifier | Element DeviceDefinition.regulatoryIdentifier is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.regulatoryIdentifier has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.regulatoryIdentifier.type |
Extension: ExtensionDeviceDefinition_RegulatoryIdentifier Slice:type | Element DeviceDefinition.regulatoryIdentifier.type is part of an existing definition because parent element DeviceDefinition.regulatoryIdentifier requires a cross-version extension.Element DeviceDefinition.regulatoryIdentifier.type is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.regulatoryIdentifier.type has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.regulatoryIdentifier.deviceIdentifier |
Extension: ExtensionDeviceDefinition_RegulatoryIdentifier Slice:deviceIdentifier | Element DeviceDefinition.regulatoryIdentifier.deviceIdentifier is part of an existing definition because parent element DeviceDefinition.regulatoryIdentifier requires a cross-version extension.Element DeviceDefinition.regulatoryIdentifier.deviceIdentifier is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.regulatoryIdentifier.deviceIdentifier has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.regulatoryIdentifier.issuer |
Extension: ExtensionDeviceDefinition_RegulatoryIdentifier Slice:issuer | Element DeviceDefinition.regulatoryIdentifier.issuer is part of an existing definition because parent element DeviceDefinition.regulatoryIdentifier requires a cross-version extension.Element DeviceDefinition.regulatoryIdentifier.issuer is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.regulatoryIdentifier.issuer has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.regulatoryIdentifier.jurisdiction |
Extension: ExtensionDeviceDefinition_RegulatoryIdentifier Slice:jurisdiction | Element DeviceDefinition.regulatoryIdentifier.jurisdiction is part of an existing definition because parent element DeviceDefinition.regulatoryIdentifier requires a cross-version extension.Element DeviceDefinition.regulatoryIdentifier.jurisdiction is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.regulatoryIdentifier.jurisdiction has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.partNumber |
Extension: ExtensionDeviceDefinition_PartNumber | Element DeviceDefinition.partNumber is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.partNumber has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.manufacturer |
Extension: ExtensionDeviceDefinition_Manufacturer | Element DeviceDefinition.manufacturer is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.manufacturer has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.deviceName |
Extension: ExtensionDeviceDefinition_DeviceName | Element DeviceDefinition.deviceName is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.deviceName has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.deviceName.name |
Extension: ExtensionDeviceDefinition_DeviceName Slice:name | Element DeviceDefinition.deviceName.name is part of an existing definition because parent element DeviceDefinition.deviceName requires a cross-version extension.Element DeviceDefinition.deviceName.name is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.deviceName.name has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.deviceName.type |
Extension: ExtensionDeviceDefinition_DeviceName Slice:type | Element DeviceDefinition.deviceName.type is part of an existing definition because parent element DeviceDefinition.deviceName requires a cross-version extension.Element DeviceDefinition.deviceName.type is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.deviceName.type has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.modelNumber |
Extension: ExtensionDeviceDefinition_ModelNumber | Element DeviceDefinition.modelNumber is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.modelNumber has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.classification |
Extension: ExtensionDeviceDefinition_Classification | Element DeviceDefinition.classification is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.classification has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.classification.type |
Extension: ExtensionDeviceDefinition_Classification Slice:type | Element DeviceDefinition.classification.type is part of an existing definition because parent element DeviceDefinition.classification requires a cross-version extension.Element DeviceDefinition.classification.type is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.classification.type has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.classification.justification |
Extension: ExtensionDeviceDefinition_Classification Slice:justification | Element DeviceDefinition.classification.justification is part of an existing definition because parent element DeviceDefinition.classification requires a cross-version extension.Element DeviceDefinition.classification.justification is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.classification.justification has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.conformsTo |
Standard Extension: device-conformsTo | Element DeviceDefinition.conformsTo is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.conformsTo has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).An externally-defined extension that has been mapped as the representation of FHIR R5 element DeviceDefinition.conformsTo: http://hl7.org/fhir/StructureDefinition/device-conformsTo. |
DeviceDefinition.conformsTo.category |
Extension: ExtensionDeviceDefinition_ConformsTo Slice:category | Element DeviceDefinition.conformsTo.category is part of an existing definition because parent element DeviceDefinition.conformsTo requires a cross-version extension.Element DeviceDefinition.conformsTo.category is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.conformsTo.category has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.conformsTo.specification |
Extension: ExtensionDeviceDefinition_ConformsTo Slice:specification | Element DeviceDefinition.conformsTo.specification is part of an existing definition because parent element DeviceDefinition.conformsTo requires a cross-version extension.Element DeviceDefinition.conformsTo.specification is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.conformsTo.specification has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.conformsTo.version |
Extension: ExtensionDeviceDefinition_ConformsTo Slice:version | Element DeviceDefinition.conformsTo.version is part of an existing definition because parent element DeviceDefinition.conformsTo requires a cross-version extension.Element DeviceDefinition.conformsTo.version is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.conformsTo.version has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.conformsTo.source |
Extension: ExtensionDeviceDefinition_ConformsTo Slice:source | Element DeviceDefinition.conformsTo.source is part of an existing definition because parent element DeviceDefinition.conformsTo requires a cross-version extension.Element DeviceDefinition.conformsTo.source is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.conformsTo.source has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.hasPart |
Extension: ExtensionDeviceDefinition_HasPart | Element DeviceDefinition.hasPart is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.hasPart has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.hasPart.reference |
Extension: ExtensionDeviceDefinition_HasPart Slice:reference | Element DeviceDefinition.hasPart.reference is part of an existing definition because parent element DeviceDefinition.hasPart requires a cross-version extension.Element DeviceDefinition.hasPart.reference is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.hasPart.reference has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.hasPart.count |
Extension: ExtensionDeviceDefinition_HasPart Slice:count | Element DeviceDefinition.hasPart.count is part of an existing definition because parent element DeviceDefinition.hasPart requires a cross-version extension.Element DeviceDefinition.hasPart.count is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.hasPart.count has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.packaging |
Extension: ExtensionDeviceDefinition_Packaging | Element DeviceDefinition.packaging is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.packaging has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.packaging.identifier |
Extension: ExtensionDeviceDefinition_Packaging Slice:identifier | Element DeviceDefinition.packaging.identifier is part of an existing definition because parent element DeviceDefinition.packaging requires a cross-version extension.Element DeviceDefinition.packaging.identifier is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.packaging.identifier has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.packaging.type |
Extension: ExtensionDeviceDefinition_Packaging Slice:type | Element DeviceDefinition.packaging.type is part of an existing definition because parent element DeviceDefinition.packaging requires a cross-version extension.Element DeviceDefinition.packaging.type is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.packaging.type has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.packaging.count |
Extension: ExtensionDeviceDefinition_Packaging Slice:count | Element DeviceDefinition.packaging.count is part of an existing definition because parent element DeviceDefinition.packaging requires a cross-version extension.Element DeviceDefinition.packaging.count is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.packaging.count has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.packaging.distributor |
Extension: ExtensionDeviceDefinition_Packaging Slice:distributor | Element DeviceDefinition.packaging.distributor is part of an existing definition because parent element DeviceDefinition.packaging requires a cross-version extension.Element DeviceDefinition.packaging.distributor is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.packaging.distributor has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.packaging.distributor.name |
Extension: ExtensionDeviceDefinition_Packaging_Distributor Slice:name | Element DeviceDefinition.packaging.distributor.name is part of an existing definition because parent element DeviceDefinition.packaging.distributor requires a cross-version extension.Element DeviceDefinition.packaging.distributor.name is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.packaging.distributor.name has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.packaging.distributor.organizationReference |
Extension: ExtensionDeviceDefinition_Packaging_Distributor Slice:organizationReference | Element DeviceDefinition.packaging.distributor.organizationReference is part of an existing definition because parent element DeviceDefinition.packaging.distributor requires a cross-version extension.Element DeviceDefinition.packaging.distributor.organizationReference is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.packaging.distributor.organizationReference has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.packaging.udiDeviceIdentifier |
Extension: ExtensionDeviceDefinition_Packaging Slice:udiDeviceIdentifier Extension: ExtensionDeviceDefinition_UdiDeviceIdentifier |
Element DeviceDefinition.packaging.udiDeviceIdentifier is part of an existing definition because parent element DeviceDefinition.packaging requires a cross-version extension.Element DeviceDefinition.packaging.udiDeviceIdentifier is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.packaging.udiDeviceIdentifier has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.packaging.packaging |
Extension: ExtensionDeviceDefinition_Packaging Slice:packaging | Element DeviceDefinition.packaging.packaging is part of an existing definition because parent element DeviceDefinition.packaging requires a cross-version extension.Element DeviceDefinition.packaging.packaging is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.packaging.packaging has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.version |
Extension: ExtensionDeviceDefinition_Version | Element DeviceDefinition.version is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.version has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.version.type |
Extension: ExtensionDeviceDefinition_Version Slice:type | Element DeviceDefinition.version.type is part of an existing definition because parent element DeviceDefinition.version requires a cross-version extension.Element DeviceDefinition.version.type is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.version.type has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.version.component |
Extension: ExtensionDeviceDefinition_Version Slice:component | Element DeviceDefinition.version.component is part of an existing definition because parent element DeviceDefinition.version requires a cross-version extension.Element DeviceDefinition.version.component is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.version.component has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.version.value |
Extension: ExtensionDeviceDefinition_Version Slice:value | Element DeviceDefinition.version.value is part of an existing definition because parent element DeviceDefinition.version requires a cross-version extension.Element DeviceDefinition.version.value is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.version.value has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.safety |
Extension: ExtensionDeviceDefinition_Safety | Element DeviceDefinition.safety is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.safety has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.shelfLifeStorage |
Extension: ExtensionDeviceDefinition_ShelfLifeStorage | Element DeviceDefinition.shelfLifeStorage is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.shelfLifeStorage has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.languageCode |
Extension: ExtensionDeviceDefinition_LanguageCode | Element DeviceDefinition.languageCode is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.languageCode has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.property |
Extension: ExtensionDeviceDefinition_Property | Element DeviceDefinition.property is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.property has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.property.type |
Extension: ExtensionDeviceDefinition_Property Slice:type | Element DeviceDefinition.property.type is part of an existing definition because parent element DeviceDefinition.property requires a cross-version extension.Element DeviceDefinition.property.type is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.property.type has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.property.value[x] |
Extension: ExtensionDeviceDefinition_Property Slice:value | Element DeviceDefinition.property.value[x] is part of an existing definition because parent element DeviceDefinition.property requires a cross-version extension.Element DeviceDefinition.property.value[x] is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.property.value[x] has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.owner |
Extension: ExtensionDeviceDefinition_Owner | Element DeviceDefinition.owner is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.owner has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.contact |
Standard Extension: artifact-contact | Element DeviceDefinition.contact is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.contact has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).An externally-defined extension that has been mapped as the representation of FHIR R5 element DeviceDefinition.contact: http://hl7.org/fhir/StructureDefinition/artifact-contact. |
DeviceDefinition.link |
Extension: ExtensionDeviceDefinition_Link | Element DeviceDefinition.link is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.link has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.link.relation |
Extension: ExtensionDeviceDefinition_Link Slice:relation | Element DeviceDefinition.link.relation is part of an existing definition because parent element DeviceDefinition.link requires a cross-version extension.Element DeviceDefinition.link.relation is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.link.relation has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.link.relatedDevice |
Extension: ExtensionDeviceDefinition_Link Slice:relatedDevice | Element DeviceDefinition.link.relatedDevice is part of an existing definition because parent element DeviceDefinition.link requires a cross-version extension.Element DeviceDefinition.link.relatedDevice is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.link.relatedDevice has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.note |
Extension: ExtensionDeviceDefinition_Note | Element DeviceDefinition.note is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.note has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.material |
Extension: ExtensionDeviceDefinition_Material | Element DeviceDefinition.material is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.material has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.material.substance |
Extension: ExtensionDeviceDefinition_Material Slice:substance | Element DeviceDefinition.material.substance is part of an existing definition because parent element DeviceDefinition.material requires a cross-version extension.Element DeviceDefinition.material.substance is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.material.substance has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.material.alternate |
Extension: ExtensionDeviceDefinition_Material Slice:alternate | Element DeviceDefinition.material.alternate is part of an existing definition because parent element DeviceDefinition.material requires a cross-version extension.Element DeviceDefinition.material.alternate is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.material.alternate has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.material.allergenicIndicator |
Extension: ExtensionDeviceDefinition_Material Slice:allergenicIndicator | Element DeviceDefinition.material.allergenicIndicator is part of an existing definition because parent element DeviceDefinition.material requires a cross-version extension.Element DeviceDefinition.material.allergenicIndicator is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.material.allergenicIndicator has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.productionIdentifierInUDI |
Extension: ExtensionDeviceDefinition_ProductionIdentifierInUDI | Element DeviceDefinition.productionIdentifierInUDI is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.productionIdentifierInUDI has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.guideline |
Extension: ExtensionDeviceDefinition_Guideline | Element DeviceDefinition.guideline is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.guideline has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.guideline.useContext |
Extension: ExtensionDeviceDefinition_Guideline Slice:useContext | Element DeviceDefinition.guideline.useContext is part of an existing definition because parent element DeviceDefinition.guideline requires a cross-version extension.Element DeviceDefinition.guideline.useContext is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.guideline.useContext has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.guideline.usageInstruction |
Extension: ExtensionDeviceDefinition_Guideline Slice:usageInstruction | Element DeviceDefinition.guideline.usageInstruction is part of an existing definition because parent element DeviceDefinition.guideline requires a cross-version extension.Element DeviceDefinition.guideline.usageInstruction is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.guideline.usageInstruction has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.guideline.relatedArtifact |
Extension: ExtensionDeviceDefinition_Guideline Slice:relatedArtifact | Element DeviceDefinition.guideline.relatedArtifact is part of an existing definition because parent element DeviceDefinition.guideline requires a cross-version extension.Element DeviceDefinition.guideline.relatedArtifact is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.guideline.relatedArtifact has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.guideline.indication |
Extension: ExtensionDeviceDefinition_Guideline Slice:indication | Element DeviceDefinition.guideline.indication is part of an existing definition because parent element DeviceDefinition.guideline requires a cross-version extension.Element DeviceDefinition.guideline.indication is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.guideline.indication has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.guideline.contraindication |
Extension: ExtensionDeviceDefinition_Guideline Slice:contraindication | Element DeviceDefinition.guideline.contraindication is part of an existing definition because parent element DeviceDefinition.guideline requires a cross-version extension.Element DeviceDefinition.guideline.contraindication is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.guideline.contraindication has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.guideline.warning |
Extension: ExtensionDeviceDefinition_Guideline Slice:warning | Element DeviceDefinition.guideline.warning is part of an existing definition because parent element DeviceDefinition.guideline requires a cross-version extension.Element DeviceDefinition.guideline.warning is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.guideline.warning has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.guideline.intendedUse |
Extension: ExtensionDeviceDefinition_Guideline Slice:intendedUse | Element DeviceDefinition.guideline.intendedUse is part of an existing definition because parent element DeviceDefinition.guideline requires a cross-version extension.Element DeviceDefinition.guideline.intendedUse is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.guideline.intendedUse has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.correctiveAction |
Extension: ExtensionDeviceDefinition_CorrectiveAction | Element DeviceDefinition.correctiveAction is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.correctiveAction has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.correctiveAction.recall |
Extension: ExtensionDeviceDefinition_CorrectiveAction Slice:recall | Element DeviceDefinition.correctiveAction.recall is part of an existing definition because parent element DeviceDefinition.correctiveAction requires a cross-version extension.Element DeviceDefinition.correctiveAction.recall is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.correctiveAction.recall has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.correctiveAction.scope |
Extension: ExtensionDeviceDefinition_CorrectiveAction Slice:scope | Element DeviceDefinition.correctiveAction.scope is part of an existing definition because parent element DeviceDefinition.correctiveAction requires a cross-version extension.Element DeviceDefinition.correctiveAction.scope is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.correctiveAction.scope has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.correctiveAction.period |
Extension: ExtensionDeviceDefinition_CorrectiveAction Slice:period | Element DeviceDefinition.correctiveAction.period is part of an existing definition because parent element DeviceDefinition.correctiveAction requires a cross-version extension.Element DeviceDefinition.correctiveAction.period is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.correctiveAction.period has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.chargeItem |
Extension: ExtensionDeviceDefinition_ChargeItem | Element DeviceDefinition.chargeItem is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.chargeItem has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.chargeItem.chargeItemCode |
Extension: ExtensionDeviceDefinition_ChargeItem Slice:chargeItemCode | Element DeviceDefinition.chargeItem.chargeItemCode is part of an existing definition because parent element DeviceDefinition.chargeItem requires a cross-version extension.Element DeviceDefinition.chargeItem.chargeItemCode is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.chargeItem.chargeItemCode has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.chargeItem.count |
Extension: ExtensionDeviceDefinition_ChargeItem Slice:count | Element DeviceDefinition.chargeItem.count is part of an existing definition because parent element DeviceDefinition.chargeItem requires a cross-version extension.Element DeviceDefinition.chargeItem.count is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.chargeItem.count has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.chargeItem.effectivePeriod |
Extension: ExtensionDeviceDefinition_ChargeItem Slice:effectivePeriod | Element DeviceDefinition.chargeItem.effectivePeriod is part of an existing definition because parent element DeviceDefinition.chargeItem requires a cross-version extension.Element DeviceDefinition.chargeItem.effectivePeriod is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.chargeItem.effectivePeriod has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
DeviceDefinition.chargeItem.useContext |
Extension: ExtensionDeviceDefinition_ChargeItem Slice:useContext | Element DeviceDefinition.chargeItem.useContext is part of an existing definition because parent element DeviceDefinition.chargeItem requires a cross-version extension.Element DeviceDefinition.chargeItem.useContext is not mapped to FHIR STU3, since FHIR R5 DeviceDefinition is not mapped.Element DeviceDefinition.chargeItem.useContext has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |