Extensions for Using Data Elements from FHIR R5 in FHIR STU3 - Downloaded Version null See the Directory of published versions
The FHIR R5 resource is represented in FHIR STU3 via the Device resource.
Note that there is a profile defined to simplify use of this cross-version resource representation:Profile: Device
A computable version of the following element information is available in: R5DeviceElementMapToR3
| Source Element (FHIR R5) | Target(s) | Comments |
|---|---|---|
Device |
||
Device.meta |
Device.meta | Element Device.meta is mapped to FHIR STU3 element Device.meta as Equivalent. |
Device.implicitRules |
Device.implicitRules | Element Device.implicitRules is mapped to FHIR STU3 element Device.implicitRules as Equivalent. |
Device.language |
Device.language | Element Device.language is mapped to FHIR STU3 element Device.language as Equivalent. |
Device.text |
Device.text | Element Device.text is mapped to FHIR STU3 element Device.text as Equivalent. |
Device.contained |
Device.contained | Element Device.contained is mapped to FHIR STU3 element Device.contained as SourceIsBroaderThanTarget. |
Device.identifier |
Device.identifier | Element Device.identifier is mapped to FHIR STU3 element Device.identifier as Equivalent. |
Device.displayName |
Device.udi Extension: ExtensionDevice_DisplayName |
Element Device.displayName is mapped to FHIR STU3 element Device.udi as RelatedTo.The mappings for Device.displayName do not cover the following types: string.The mappings for Device.displayName do not cover the following types based on type expansion: value. |
Device.definition |
Extension: ExtensionDevice_Definition | Element Device.definition has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.definition has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Device.udiCarrier |
Device.udi | Element Device.udiCarrier is mapped to FHIR STU3 element Device.udi as SourceIsBroaderThanTarget. |
Device.udiCarrier.deviceIdentifier |
Device.udi.deviceIdentifier | Element Device.udiCarrier.deviceIdentifier is mapped to FHIR STU3 element Device.udi.deviceIdentifier as Equivalent. |
Device.udiCarrier.issuer |
Device.udi.issuer | Element Device.udiCarrier.issuer is mapped to FHIR STU3 element Device.udi.issuer as Equivalent. |
Device.udiCarrier.jurisdiction |
Device.udi.jurisdiction | Element Device.udiCarrier.jurisdiction is mapped to FHIR STU3 element Device.udi.jurisdiction as Equivalent. |
Device.udiCarrier.carrierAIDC |
Device.udi.carrierAIDC | Element Device.udiCarrier.carrierAIDC is mapped to FHIR STU3 element Device.udi.carrierAIDC as Equivalent. |
Device.udiCarrier.carrierHRF |
Device.udi.carrierHRF | Element Device.udiCarrier.carrierHRF is mapped to FHIR STU3 element Device.udi.carrierHRF as Equivalent. |
Device.udiCarrier.entryType |
Device.udi.entryType Extension: ExtensionDevice_UdiCarrier_EntryType |
Element Device.udiCarrier.entryType is mapped to FHIR STU3 element Device.udi.entryType as RelatedTo.The mappings for Device.udiCarrier.entryType do not allow expression of the necessary codes, per the bindings on the source and target. |
Device.status |
Device.status | Element Device.status is mapped to FHIR STU3 element Device.status as SourceIsNarrowerThanTarget.The mappings for Device.status do not allow expression of the necessary codes, per the bindings on the source and target. |
Device.availabilityStatus |
Extension: ExtensionDevice_AvailabilityStatus | Element Device.availabilityStatus has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.availabilityStatus has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Device.biologicalSourceEvent |
Extension: ExtensionDevice_BiologicalSourceEvent | Element Device.biologicalSourceEvent has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.biologicalSourceEvent has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Device.manufacturer |
Device.manufacturer | Element Device.manufacturer is mapped to FHIR STU3 element Device.manufacturer as Equivalent. |
Device.manufactureDate |
Device.manufactureDate | Element Device.manufactureDate is mapped to FHIR STU3 element Device.manufactureDate as Equivalent. |
Device.expirationDate |
Device.expirationDate | Element Device.expirationDate is mapped to FHIR STU3 element Device.expirationDate as Equivalent. |
Device.lotNumber |
Device.lotNumber | Element Device.lotNumber is mapped to FHIR STU3 element Device.lotNumber as Equivalent. |
Device.serialNumber |
Extension: ExtensionDevice_SerialNumber | Element Device.serialNumber has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.serialNumber has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Device.name |
Device.udi | Element Device.name is mapped to FHIR STU3 element Device.udi as SourceIsBroaderThanTarget. |
Device.name.value |
Device.udi Extension: ExtensionDevice_Name_Value |
Element Device.name.value is mapped to FHIR STU3 element Device.udi as RelatedTo.The mappings for Device.name.value do not cover the following types: string.The mappings for Device.name.value do not cover the following types based on type expansion: value. |
Device.name.type |
Extension: ExtensionDevice_Name_Type | Element Device.name.type has a context of Device.udi based on following the parent source element upwards and mapping to Device.Element Device.name.type has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Device.name.display |
Device.udi Modifier Extension: ExtensionDevice_Name_Display |
Element Device.name.display is mapped to FHIR STU3 element Device.udi as RelatedTo.The mappings for Device.name.display do not cover the following types: boolean.The mappings for Device.name.display do not cover the following types based on type expansion: value. |
Device.modelNumber |
Device.model | Element Device.modelNumber is mapped to FHIR STU3 element Device.model as Equivalent. |
Device.partNumber |
Extension: ExtensionDevice_PartNumber | Element Device.partNumber has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.partNumber has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Device.category |
Extension: ExtensionDevice_Category | Element Device.category has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.category has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Device.type |
Device.type | Element Device.type is mapped to FHIR STU3 element Device.type as SourceIsBroaderThanTarget. |
Device.version |
Device.version | Element Device.version is mapped to FHIR STU3 element Device.version as SourceIsBroaderThanTarget. |
Device.version.type |
Extension: ExtensionDevice_Version_Type | Element Device.version.type has a context of Device.version based on following the parent source element upwards and mapping to Device.Element Device.version.type has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Device.version.component |
Extension: ExtensionDevice_Version_Component | Element Device.version.component has a context of Device.version based on following the parent source element upwards and mapping to Device.Element Device.version.component has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Device.version.installDate |
Extension: ExtensionDevice_Version_InstallDate | Element Device.version.installDate has a context of Device.version based on following the parent source element upwards and mapping to Device.Element Device.version.installDate has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Device.version.value |
Extension: ExtensionDevice_Version_Value | Element Device.version.value has a context of Device.version based on following the parent source element upwards and mapping to Device.Element Device.version.value has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Device.conformsTo |
Standard Extension: device-conformsTo | Element Device.conformsTo has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.conformsTo has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).An externally-defined extension that has been mapped as the representation of FHIR R5 element Device.conformsTo: http://hl7.org/fhir/StructureDefinition/device-conformsTo. |
Device.conformsTo.category |
Extension: ExtensionDevice_ConformsTo Slice:category | Element Device.conformsTo.category is part of an existing definition because parent element Device.conformsTo requires a cross-version extension.Element Device.conformsTo.category has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.conformsTo.category has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Device.conformsTo.specification |
Extension: ExtensionDevice_ConformsTo Slice:specification | Element Device.conformsTo.specification is part of an existing definition because parent element Device.conformsTo requires a cross-version extension.Element Device.conformsTo.specification has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.conformsTo.specification has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Device.conformsTo.version |
Extension: ExtensionDevice_ConformsTo Slice:version | Element Device.conformsTo.version is part of an existing definition because parent element Device.conformsTo requires a cross-version extension.Element Device.conformsTo.version has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.conformsTo.version has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Device.property |
Extension: ExtensionDevice_Property | Element Device.property has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.property has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Device.property.type |
Extension: ExtensionDevice_Property Slice:type | Element Device.property.type is part of an existing definition because parent element Device.property requires a cross-version extension.Element Device.property.type has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.property.type has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Device.property.value[x] |
Extension: ExtensionDevice_Property Slice:value | Element Device.property.value[x] is part of an existing definition because parent element Device.property requires a cross-version extension.Element Device.property.value[x] has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.property.value[x] has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Device.mode |
Extension: ExtensionDevice_Mode | Element Device.mode has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.mode has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Device.cycle |
Extension: ExtensionDevice_Cycle | Element Device.cycle has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.cycle has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Device.duration |
Extension: ExtensionDevice_Duration | Element Device.duration has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.duration has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Device.owner |
Device.owner Standard Extension: alternate-reference |
Element Device.owner is mapped to FHIR STU3 element Device.owner as SourceIsBroaderThanTarget.The mappings for Device.owner do not cover the following types based on type expansion: display, identifier, reference, type.The standard extension alternate-reference has been mapped as the representation of FHIR R5 element Device.owner with unmapped reference targets: Organization. |
Device.contact |
Device.contact | Element Device.contact is mapped to FHIR STU3 element Device.contact as Equivalent. |
Device.location |
Device.location Standard Extension: alternate-reference |
Element Device.location is mapped to FHIR STU3 element Device.location as SourceIsBroaderThanTarget.The mappings for Device.location do not cover the following types based on type expansion: display, identifier, reference, type.The standard extension alternate-reference has been mapped as the representation of FHIR R5 element Device.location with unmapped reference targets: Location. |
Device.url |
Device.url | Element Device.url is mapped to FHIR STU3 element Device.url as Equivalent. |
Device.endpoint |
Extension: ExtensionDevice_Endpoint | Element Device.endpoint has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.endpoint has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Device.gateway |
Extension: ExtensionDevice_Gateway | Element Device.gateway has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.gateway has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Device.note |
Device.note | Element Device.note is mapped to FHIR STU3 element Device.note as Equivalent. |
Device.safety |
Device.safety | Element Device.safety is mapped to FHIR STU3 element Device.safety as Equivalent. |
Device.parent |
Extension: ExtensionDevice_Parent | Element Device.parent has a context of Device based on following the parent source element upwards and mapping to Device.Element Device.parent has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |