Extensions for Using Data Elements from FHIR R5 in FHIR STU3 - Downloaded Version null See the Directory of published versions
The FHIR R5 resource is represented in FHIR STU3 via the ChargeItem resource.
Note that there is a profile defined to simplify use of this cross-version resource representation:Profile: ChargeItem
A computable version of the following element information is available in: R5ChargeItemElementMapToR3
| Source Element (FHIR R5) | Target(s) | Comments |
|---|---|---|
ChargeItem |
||
ChargeItem.meta |
ChargeItem.meta | Element ChargeItem.meta is mapped to FHIR STU3 element ChargeItem.meta as Equivalent. |
ChargeItem.implicitRules |
ChargeItem.implicitRules | Element ChargeItem.implicitRules is mapped to FHIR STU3 element ChargeItem.implicitRules as Equivalent. |
ChargeItem.language |
ChargeItem.language | Element ChargeItem.language is mapped to FHIR STU3 element ChargeItem.language as Equivalent. |
ChargeItem.text |
ChargeItem.text | Element ChargeItem.text is mapped to FHIR STU3 element ChargeItem.text as Equivalent. |
ChargeItem.contained |
ChargeItem.contained | Element ChargeItem.contained is mapped to FHIR STU3 element ChargeItem.contained as SourceIsBroaderThanTarget. |
ChargeItem.identifier |
ChargeItem.identifier | Element ChargeItem.identifier is mapped to FHIR STU3 element ChargeItem.identifier as SourceIsBroaderThanTarget. |
ChargeItem.definitionUri |
ChargeItem.definition | Element ChargeItem.definitionUri is mapped to FHIR STU3 element ChargeItem.definition as Equivalent. |
ChargeItem.definitionCanonical |
Extension: ExtensionChargeItem_DefinitionCanonical | Element ChargeItem.definitionCanonical has a context of ChargeItem based on following the parent source element upwards and mapping to ChargeItem.Element ChargeItem.definitionCanonical has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ChargeItem.status |
ChargeItem.status | Element ChargeItem.status is mapped to FHIR STU3 element ChargeItem.status as Equivalent. |
ChargeItem.partOf |
ChargeItem.partOf Standard Extension: alternate-reference |
Element ChargeItem.partOf is mapped to FHIR STU3 element ChargeItem.partOf as SourceIsBroaderThanTarget.The mappings for ChargeItem.partOf do not cover the following types based on type expansion: display, identifier, reference, type.The standard extension alternate-reference has been mapped as the representation of FHIR R5 element ChargeItem.partOf with unmapped reference targets: ChargeItem. |
ChargeItem.code |
ChargeItem.code | Element ChargeItem.code is mapped to FHIR STU3 element ChargeItem.code as Equivalent. |
ChargeItem.subject |
ChargeItem.subject Standard Extension: alternate-reference |
Element ChargeItem.subject is mapped to FHIR STU3 element ChargeItem.subject as SourceIsBroaderThanTarget.The mappings for ChargeItem.subject do not cover the following types based on type expansion: display, identifier, reference, type.The standard extension alternate-reference has been mapped as the representation of FHIR R5 element ChargeItem.subject with unmapped reference targets: Group, Patient. |
ChargeItem.encounter |
ChargeItem.context Standard Extension: alternate-reference |
Element ChargeItem.encounter is mapped to FHIR STU3 element ChargeItem.context as SourceIsBroaderThanTarget.The mappings for ChargeItem.encounter do not cover the following types based on type expansion: display, identifier, reference, type.The standard extension alternate-reference has been mapped as the representation of FHIR R5 element ChargeItem.encounter with unmapped reference targets: Encounter. |
ChargeItem.occurrence[x] |
ChargeItem.occurrence[x] | Element ChargeItem.occurrence[x] is mapped to FHIR STU3 element ChargeItem.occurrence[x] as Equivalent.The target context ChargeItem.occurrence[x] is a choice-type element and cannot directly hold extensions. The context is moved up to parent element ChargeItem. |
ChargeItem.performer |
ChargeItem.participant | Element ChargeItem.performer is mapped to FHIR STU3 element ChargeItem.participant as Equivalent. |
ChargeItem.performer.function |
ChargeItem.participant.role | Element ChargeItem.performer.function is mapped to FHIR STU3 element ChargeItem.participant.role as Equivalent. |
ChargeItem.performer.actor |
ChargeItem.participant.actor Standard Extension: alternate-reference |
Element ChargeItem.performer.actor is mapped to FHIR STU3 element ChargeItem.participant.actor as SourceIsBroaderThanTarget.The standard extension alternate-reference has been mapped as the representation of FHIR R5 element ChargeItem.performer.actor with unmapped reference targets: CareTeam, Device, HealthcareService, Organization, Patient, Practitioner, PractitionerRole, RelatedPerson. |
ChargeItem.performingOrganization |
ChargeItem.performingOrganization Standard Extension: alternate-reference |
Element ChargeItem.performingOrganization is mapped to FHIR STU3 element ChargeItem.performingOrganization as SourceIsBroaderThanTarget.The mappings for ChargeItem.performingOrganization do not cover the following types based on type expansion: display, identifier, reference, type.The standard extension alternate-reference has been mapped as the representation of FHIR R5 element ChargeItem.performingOrganization with unmapped reference targets: Organization. |
ChargeItem.requestingOrganization |
ChargeItem.requestingOrganization Standard Extension: alternate-reference |
Element ChargeItem.requestingOrganization is mapped to FHIR STU3 element ChargeItem.requestingOrganization as SourceIsBroaderThanTarget.The mappings for ChargeItem.requestingOrganization do not cover the following types based on type expansion: display, identifier, reference, type.The standard extension alternate-reference has been mapped as the representation of FHIR R5 element ChargeItem.requestingOrganization with unmapped reference targets: Organization. |
ChargeItem.costCenter |
Extension: ExtensionChargeItem_CostCenter | Element ChargeItem.costCenter has a context of ChargeItem based on following the parent source element upwards and mapping to ChargeItem.Element ChargeItem.costCenter has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ChargeItem.quantity |
ChargeItem.quantity | Element ChargeItem.quantity is mapped to FHIR STU3 element ChargeItem.quantity as Equivalent. |
ChargeItem.bodysite |
ChargeItem.bodysite | Element ChargeItem.bodysite is mapped to FHIR STU3 element ChargeItem.bodysite as Equivalent. |
ChargeItem.unitPriceComponent |
Extension: ExtensionChargeItem_UnitPriceComponent | Element ChargeItem.unitPriceComponent has a context of ChargeItem based on following the parent source element upwards and mapping to ChargeItem.Element ChargeItem.unitPriceComponent has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ChargeItem.totalPriceComponent |
Extension: ExtensionChargeItem_TotalPriceComponent | Element ChargeItem.totalPriceComponent has a context of ChargeItem based on following the parent source element upwards and mapping to ChargeItem.Element ChargeItem.totalPriceComponent has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ChargeItem.overrideReason |
ChargeItem.overrideReason Extension: ExtensionChargeItem_OverrideReason |
Element ChargeItem.overrideReason is mapped to FHIR STU3 element ChargeItem.overrideReason as SourceIsBroaderThanTarget.The mappings for ChargeItem.overrideReason do not cover the following types: CodeableConcept.The mappings for ChargeItem.overrideReason do not cover the following types based on type expansion: coding. |
ChargeItem.enterer |
ChargeItem.enterer Standard Extension: alternate-reference |
Element ChargeItem.enterer is mapped to FHIR STU3 element ChargeItem.enterer as SourceIsBroaderThanTarget.The standard extension alternate-reference has been mapped as the representation of FHIR R5 element ChargeItem.enterer with unmapped reference targets: Device, Organization, Patient, Practitioner, PractitionerRole, RelatedPerson. |
ChargeItem.enteredDate |
ChargeItem.enteredDate | Element ChargeItem.enteredDate is mapped to FHIR STU3 element ChargeItem.enteredDate as Equivalent. |
ChargeItem.reason |
ChargeItem.reason | Element ChargeItem.reason is mapped to FHIR STU3 element ChargeItem.reason as Equivalent. |
ChargeItem.service |
ChargeItem.service Extension: ExtensionChargeItem_Service |
Element ChargeItem.service is mapped to FHIR STU3 element ChargeItem.service as SourceIsBroaderThanTarget.The mappings for ChargeItem.service do not cover the following types: CodeableReference. |
ChargeItem.product |
Extension: ExtensionChargeItem_Product | Element ChargeItem.product has a context of ChargeItem based on following the parent source element upwards and mapping to ChargeItem.Element ChargeItem.product has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ChargeItem.account |
ChargeItem.account Standard Extension: alternate-reference |
Element ChargeItem.account is mapped to FHIR STU3 element ChargeItem.account as SourceIsBroaderThanTarget.The mappings for ChargeItem.account do not cover the following types based on type expansion: display, identifier, reference, type.The standard extension alternate-reference has been mapped as the representation of FHIR R5 element ChargeItem.account with unmapped reference targets: Account. |
ChargeItem.note |
ChargeItem.note | Element ChargeItem.note is mapped to FHIR STU3 element ChargeItem.note as Equivalent. |
ChargeItem.supportingInformation |
ChargeItem.supportingInformation Standard Extension: alternate-reference |
Element ChargeItem.supportingInformation is mapped to FHIR STU3 element ChargeItem.supportingInformation as SourceIsBroaderThanTarget.The mappings for ChargeItem.supportingInformation do not cover the following types based on type expansion: display, identifier, reference, type.The standard extension alternate-reference has been mapped as the representation of FHIR R5 element ChargeItem.supportingInformation with unmapped reference targets: Resource. |