Extensions for Using Data Elements from FHIR R5 in FHIR STU3
0.1.0 - STU International flag

Extensions for Using Data Elements from FHIR R5 in FHIR STU3 - Downloaded Version null See the Directory of published versions

ValueSet: R5QuantityComparatorForR3

Official URL: http://hl7.org/fhir/uv/xver/ValueSet/R5-quantity-comparator-for-R3 Version: 0.1.0
Standards status: Trial-use Maturity Level: 5 Computable Name: R5QuantityComparatorForR3

This cross-version ValueSet represents content from http://hl7.org/fhir/ValueSet/quantity-comparator 5.0.0 for use in FHIR STU3 that is appropriate for use but unavailable in http://hl7.org/fhir/ValueSet/quantity-comparator|3.0.2.

This value set is part of the cross-version definitions generated to enable use of the value set http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0 as defined in FHIR R5 in FHIR STU3.

The source value set is bound to the following FHIR R5 elements:

  • Age.comparator as Required
  • Count.comparator as Required
  • Distance.comparator as Required
  • Duration.comparator as Required
  • Quantity.comparator as Required

Across FHIR versions, the value set has been mapped as:

  • http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0
  • http://hl7.org/fhir/ValueSet/quantity-comparator|4.3.0
  • http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1
  • http://hl7.org/fhir/ValueSet/quantity-comparator|3.0.2

The following concepts are not included in this cross-version definition because they have valid representations:

  • http://hl7.org/fhir/quantity-comparator#<
  • http://hl7.org/fhir/quantity-comparator#<=
  • http://hl7.org/fhir/quantity-comparator#>
  • http://hl7.org/fhir/quantity-comparator#>=

Following are the generation technical comments: One or more source concepts are either not mapped or broader than their targets, so the value set relationship is broadened. The source value set has more active concepts (5) than the target (4), so the source is broader than the target. All concepts in the comparison are listed as identical. The source and target value sets have the same number of active concepts (4). All concepts in the comparison are listed as identical. The source and target value sets have the same number of active concepts (4).

References

Logical Definition (CLD)

  • Include these codes as defined in http://hl7.org/fhir/quantity-comparator version 📍5.0.0
    CodeDisplayDefinition
    adSufficient to achieve this total quantityThe actual value is sufficient for the total quantity to equal the given value.

 

Expansion

This value set expansion contains 1 concepts.

SystemVersionCodeDisplayDefinitionJSONXML
http://hl7.org/fhir/quantity-comparator5.0.0  adSufficient to achieve this total quantityThe actual value is sufficient for the total quantity to equal the given value.

Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code