Extensions for Using Data Elements from FHIR R5 in FHIR STU3 - Downloaded Version null See the Directory of published versions
| Official URL: http://hl7.org/fhir/uv/xver/ConceptMap/R5-SupplyRequest-element-map-to-R3 | Version: 0.1.0 | |||
| Standards status: Trial-use | Maturity Level: 0 | Computable Name: R5SupplyRequestElementMapToR3 | ||
This ConceptMap represents cross-version mappings for elements from a FHIR R5 SupplyRequest to FHIR STU3.
Mapping from http://hl7.org/fhir/5.0 to http://hl7.org/fhir/3.0
Group 1 Mapping from http://hl7.org/fhir/StructureDefinition/SupplyRequest|5.0.0 to http://hl7.org/fhir/StructureDefinition/SupplyRequest|3.0.2
| Source Code | Relationship | Target Code | Comment |
| SupplyRequest.meta (meta) | is equivalent to | SupplyRequest.meta | Element `SupplyRequest.meta` is mapped to FHIR STU3 element `SupplyRequest.meta` as `Equivalent`. |
| SupplyRequest.implicitRules (implicitRules) | is equivalent to | SupplyRequest.implicitRules | Element `SupplyRequest.implicitRules` is mapped to FHIR STU3 element `SupplyRequest.implicitRules` as `Equivalent`. Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of its narrative along with other profiles, value sets, etc. |
| SupplyRequest.language (language) | is equivalent to | SupplyRequest.language | Element `SupplyRequest.language` is mapped to FHIR STU3 element `SupplyRequest.language` as `Equivalent`. Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute). |
| SupplyRequest.text (text) | is equivalent to | SupplyRequest.text | Element `SupplyRequest.text` is mapped to FHIR STU3 element `SupplyRequest.text` as `Equivalent`. Contained resources do not have a narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded information is added later. |
| SupplyRequest.contained (contained) | is equivalent to | SupplyRequest.contained | Element `SupplyRequest.contained` is mapped to FHIR STU3 element `SupplyRequest.contained` as `SourceIsBroaderThanTarget`. This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags in their meta elements, but SHALL NOT have security labels. |
| SupplyRequest.identifier (identifier) | is equivalent to | SupplyRequest.identifier | Element `SupplyRequest.identifier` is mapped to FHIR STU3 element `SupplyRequest.identifier` as `SourceIsBroaderThanTarget`. The identifier.type element is used to distinguish between the identifiers assigned by the requester/placer and the performer/filler. |
| SupplyRequest.status (status) | is equivalent to | SupplyRequest.status | Element `SupplyRequest.status` is mapped to FHIR STU3 element `SupplyRequest.status` as `Equivalent`. |
| SupplyRequest.category (category) | is equivalent to | SupplyRequest.category | Element `SupplyRequest.category` is mapped to FHIR STU3 element `SupplyRequest.category` as `Equivalent`. |
| SupplyRequest.priority (priority) | is equivalent to | SupplyRequest.priority | Element `SupplyRequest.priority` is mapped to FHIR STU3 element `SupplyRequest.priority` as `Equivalent`. |
| SupplyRequest.item (item) | maps to wider concept | SupplyRequest.orderedItem.item[x] | Element `SupplyRequest.item` is mapped to FHIR STU3 element `SupplyRequest.orderedItem.item[x]` as `SourceIsBroaderThanTarget`. The mappings for `SupplyRequest.item` do not cover the following types: CodeableReference. The target context `SupplyRequest.orderedItem.item[x]` is a choice-type element and cannot directly hold extensions. The context is moved up to parent element `SupplyRequest.orderedItem`. Note that there's a difference between a prescription - an instruction to take a medication, along with a (sometimes) implicit supply, and an explicit request to supply, with no explicit instructions. |
| SupplyRequest.quantity (quantity) | is equivalent to | SupplyRequest.orderedItem.quantity | Element `SupplyRequest.quantity` is mapped to FHIR STU3 element `SupplyRequest.orderedItem.quantity` as `Equivalent`. |
| SupplyRequest.occurrence[x] (occurrence[x]) | is equivalent to | SupplyRequest.occurrence[x] | Element `SupplyRequest.occurrence[x]` is mapped to FHIR STU3 element `SupplyRequest.occurrence[x]` as `Equivalent`. The target context `SupplyRequest.occurrence[x]` is a choice-type element and cannot directly hold extensions. The context is moved up to parent element `SupplyRequest`. |
| SupplyRequest.authoredOn (authoredOn) | is equivalent to | SupplyRequest.authoredOn | Element `SupplyRequest.authoredOn` is mapped to FHIR STU3 element `SupplyRequest.authoredOn` as `Equivalent`. |
| SupplyRequest.requester (requester) | maps to wider concept | SupplyRequest.requester.agent | Element `SupplyRequest.requester` is mapped to FHIR STU3 element `SupplyRequest.requester.agent` as `SourceIsBroaderThanTarget`. The standard extension `alternate-reference` has been mapped as the representation of FHIR R5 element `SupplyRequest.requester` with unmapped reference targets: CareTeam, Device, Organization, Patient, Practitioner, PractitionerRole, RelatedPerson. |
| SupplyRequest.supplier (supplier) | maps to wider concept | SupplyRequest.supplier | Element `SupplyRequest.supplier` is mapped to FHIR STU3 element `SupplyRequest.supplier` as `SourceIsBroaderThanTarget`. The mappings for `SupplyRequest.supplier` do not cover the following types based on type expansion: display, identifier, reference, type. The standard extension `alternate-reference` has been mapped as the representation of FHIR R5 element `SupplyRequest.supplier` with unmapped reference targets: HealthcareService, Organization. |
| SupplyRequest.reason (reason) | is related to | SupplyRequest.reason[x] | Element `SupplyRequest.reason` is mapped to FHIR STU3 element `SupplyRequest.reason[x]` as `RelatedTo`. The mappings for `SupplyRequest.reason` do not cover the following types: CodeableReference. The target context `SupplyRequest.reason[x]` is a choice-type element and cannot directly hold extensions. The context is moved up to parent element `SupplyRequest`. |
| SupplyRequest.deliverFrom (deliverFrom) | maps to wider concept | SupplyRequest.deliverFrom | Element `SupplyRequest.deliverFrom` is mapped to FHIR STU3 element `SupplyRequest.deliverFrom` as `SourceIsBroaderThanTarget`. The mappings for `SupplyRequest.deliverFrom` do not cover the following types based on type expansion: display, identifier, reference, type. The standard extension `alternate-reference` has been mapped as the representation of FHIR R5 element `SupplyRequest.deliverFrom` with unmapped reference targets: Location, Organization. |
| SupplyRequest.deliverTo (deliverTo) | maps to wider concept | SupplyRequest.deliverTo | Element `SupplyRequest.deliverTo` is mapped to FHIR STU3 element `SupplyRequest.deliverTo` as `SourceIsBroaderThanTarget`. The standard extension `alternate-reference` has been mapped as the representation of FHIR R5 element `SupplyRequest.deliverTo` with unmapped reference targets: Location, Organization, Patient, RelatedPerson. |
Group 2 Mapping from http://hl7.org/fhir/StructureDefinition/SupplyRequest|5.0.0 to R5: What other request is fulfilled by this supply request (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| SupplyRequest.basedOn (basedOn) | maps to wider concept | Extension (R5: What other request is fulfilled by this supply request (new)) | Element `SupplyRequest.basedOn` has a context of SupplyRequest.orderedItem based on following the parent source element upwards and mapping to `SupplyRequest`. Element `SupplyRequest.basedOn` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Group 3 Mapping from http://hl7.org/fhir/StructureDefinition/SupplyRequest|5.0.0 to R5: The patient for who the supply request is for (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| SupplyRequest.deliverFor (deliverFor) | maps to wider concept | Extension (R5: The patient for who the supply request is for (new)) | Element `SupplyRequest.deliverFor` has a context of SupplyRequest.orderedItem based on following the parent source element upwards and mapping to `SupplyRequest`. Element `SupplyRequest.deliverFor` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Group 4 Mapping from http://hl7.org/fhir/StructureDefinition/SupplyRequest|5.0.0 to R5: item additional typesversion: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| SupplyRequest.item (item) | maps to wider concept | Extension (R5: item additional types) | Element `SupplyRequest.item` is mapped to FHIR STU3 element `SupplyRequest.orderedItem.item[x]` as `SourceIsBroaderThanTarget`. The mappings for `SupplyRequest.item` do not cover the following types: CodeableReference. The target context `SupplyRequest.orderedItem.item[x]` is a choice-type element and cannot directly hold extensions. The context is moved up to parent element `SupplyRequest.orderedItem`. Note that there's a difference between a prescription - an instruction to take a medication, along with a (sometimes) implicit supply, and an explicit request to supply, with no explicit instructions. |
Group 5 Mapping from http://hl7.org/fhir/StructureDefinition/SupplyRequest|5.0.0 to R5: Ordered item details (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| SupplyRequest.parameter (parameter) | is equivalent to | Extension (R5: Ordered item details (new)) | Element `SupplyRequest.parameter` has a context of SupplyRequest.orderedItem based on following the parent source element upwards and mapping to `SupplyRequest`. Element `SupplyRequest.parameter` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
| SupplyRequest.parameter.code (code) | is equivalent to | Extension.extension:code (R5: Item detail (new)) | Element `SupplyRequest.parameter.code` is part of an existing definition because parent element `SupplyRequest.parameter` requires a cross-version extension. Element `SupplyRequest.parameter.code` has a context of SupplyRequest.orderedItem based on following the parent source element upwards and mapping to `SupplyRequest`. Element `SupplyRequest.parameter.code` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
| SupplyRequest.parameter.value[x] (value[x]) | is equivalent to | Extension.extension:value (R5: Value of detail (new)) | Element `SupplyRequest.parameter.value[x]` is part of an existing definition because parent element `SupplyRequest.parameter` requires a cross-version extension. Element `SupplyRequest.parameter.value[x]` has a context of SupplyRequest.orderedItem based on following the parent source element upwards and mapping to `SupplyRequest`. Element `SupplyRequest.parameter.value[x]` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). Range means device should have a value that falls somewhere within the specified range. |
Group 6 Mapping from http://hl7.org/fhir/StructureDefinition/SupplyRequest|5.0.0 to R5: The reason why the supply item was requested additional typesversion: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| SupplyRequest.reason (reason) | maps to wider concept | Extension (R5: The reason why the supply item was requested additional types) | Element `SupplyRequest.reason` is mapped to FHIR STU3 element `SupplyRequest.reason[x]` as `RelatedTo`. The mappings for `SupplyRequest.reason` do not cover the following types: CodeableReference. The target context `SupplyRequest.reason[x]` is a choice-type element and cannot directly hold extensions. The context is moved up to parent element `SupplyRequest`. |