Extensions for Using Data Elements from FHIR R5 in FHIR STU3
0.1.0 - STU International flag

Extensions for Using Data Elements from FHIR R5 in FHIR STU3 - Downloaded Version null See the Directory of published versions

: R5DeviceUsageElementMapToR3 - XML Representation

Page standards status: Trial-use Maturity Level: 0

Raw xml | Download


<ConceptMap xmlns="http://hl7.org/fhir">
  <id value="R5-DeviceUsage-element-map-to-R3"/>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: ConceptMap R5-DeviceUsage-element-map-to-R3</b></p><a name="R5-DeviceUsage-element-map-to-R3"> </a><a name="hcR5-DeviceUsage-element-map-to-R3"> </a><p>Mapping from http://hl7.org/fhir/5.0 to http://hl7.org/fhir/3.0</p><br/><p><b>Group 1 </b>Mapping from <code>http://hl7.org/fhir/StructureDefinition/DeviceUsage|5.0.0</code> to <code>http://hl7.org/fhir/StructureDefinition/DeviceUseStatement|3.0.2</code></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>DeviceUsage.meta (meta)</td><td><a href="CodeSystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>DeviceUseStatement.meta</td><td>Element `DeviceUsage.meta` is mapped to FHIR STU3 element `DeviceUseStatement.meta` as `Equivalent`.</td></tr><tr><td>DeviceUsage.implicitRules (implicitRules)</td><td><a href="CodeSystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>DeviceUseStatement.implicitRules</td><td>Element `DeviceUsage.implicitRules` is mapped to FHIR STU3 element `DeviceUseStatement.implicitRules` as `Equivalent`.
Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of its narrative along with other profiles, value sets, etc.</td></tr><tr><td>DeviceUsage.language (language)</td><td><a href="CodeSystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>DeviceUseStatement.language</td><td>Element `DeviceUsage.language` is mapped to FHIR STU3 element `DeviceUseStatement.language` as `Equivalent`.
Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies  to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute).</td></tr><tr><td>DeviceUsage.text (text)</td><td><a href="CodeSystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>DeviceUseStatement.text</td><td>Element `DeviceUsage.text` is mapped to FHIR STU3 element `DeviceUseStatement.text` as `Equivalent`.
Contained resources do not have a narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied).  This may be necessary for data from legacy systems where information is captured as a &quot;text blob&quot; or where text is additionally entered raw or narrated and encoded information is added later.</td></tr><tr><td>DeviceUsage.contained (contained)</td><td><a href="CodeSystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>DeviceUseStatement.contained</td><td>Element `DeviceUsage.contained` is mapped to FHIR STU3 element `DeviceUseStatement.contained` as `SourceIsBroaderThanTarget`.
This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags in their meta elements, but SHALL NOT have security labels.</td></tr><tr><td>DeviceUsage.identifier (identifier)</td><td><a href="CodeSystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>DeviceUseStatement.identifier</td><td>Element `DeviceUsage.identifier` is mapped to FHIR STU3 element `DeviceUseStatement.identifier` as `Equivalent`.</td></tr><tr><td>DeviceUsage.status (status)</td><td><a href="CodeSystem-concept-map-relationship.html#wider" title="wider">maps to wider concept</a></td><td>DeviceUseStatement.status</td><td>Element `DeviceUsage.status` is mapped to FHIR STU3 element `DeviceUseStatement.status` as `SourceIsBroaderThanTarget`.
The target context `DeviceUseStatement.status` is a modifier element, so this extension does not need to be defined as a modifier.
DeviceUseStatment is a statement at a point in time.  The status is only representative at the point when it was asserted.  The value set for contains codes that assert the status of the use  by the patient (for example, stopped or on hold) as well as codes that assert the status of the resource itself (for example, entered in error).

This element is labeled as a modifier because the status contains the codes that mark the statement as not currently valid.</td></tr><tr><td>DeviceUsage.patient (patient)</td><td><a href="CodeSystem-concept-map-relationship.html#wider" title="wider">maps to wider concept</a></td><td>DeviceUseStatement.subject</td><td>Element `DeviceUsage.patient` is mapped to FHIR STU3 element `DeviceUseStatement.subject` as `SourceIsBroaderThanTarget`.
The mappings for `DeviceUsage.patient` do not cover the following types based on type expansion: display, identifier, reference, type.
The standard extension `alternate-reference` has been mapped as the representation of FHIR R5 element `DeviceUsage.patient` with unmapped reference targets: Patient.</td></tr><tr><td>DeviceUsage.timing[x] (timing[x])</td><td><a href="CodeSystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>DeviceUseStatement.timing[x]</td><td>Element `DeviceUsage.timing[x]` is mapped to FHIR STU3 element `DeviceUseStatement.timing[x]` as `Equivalent`.
The target context `DeviceUseStatement.timing[x]` is a choice-type element and cannot directly hold extensions. The context is moved up to parent element `DeviceUseStatement`.</td></tr><tr><td>DeviceUsage.dateAsserted (dateAsserted)</td><td><a href="CodeSystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>DeviceUseStatement.recordedOn</td><td>Element `DeviceUsage.dateAsserted` is mapped to FHIR STU3 element `DeviceUseStatement.recordedOn` as `Equivalent`.</td></tr><tr><td>DeviceUsage.informationSource (informationSource)</td><td><a href="CodeSystem-concept-map-relationship.html#wider" title="wider">maps to wider concept</a></td><td>DeviceUseStatement.source</td><td>Element `DeviceUsage.informationSource` is mapped to FHIR STU3 element `DeviceUseStatement.source` as `SourceIsBroaderThanTarget`.
The standard extension `alternate-reference` has been mapped as the representation of FHIR R5 element `DeviceUsage.informationSource` with unmapped reference targets: Organization, Patient, Practitioner, PractitionerRole, RelatedPerson.</td></tr><tr><td>DeviceUsage.device (device)</td><td><a href="CodeSystem-concept-map-relationship.html#wider" title="wider">maps to wider concept</a></td><td>DeviceUseStatement.device</td><td>Element `DeviceUsage.device` is mapped to FHIR STU3 element `DeviceUseStatement.device` as `SourceIsBroaderThanTarget`.
The mappings for `DeviceUsage.device` do not cover the following types: CodeableReference.
The mappings for `DeviceUsage.device` do not cover the following types based on type expansion: concept.</td></tr><tr><td>DeviceUsage.reason (reason)</td><td><a href="CodeSystem-concept-map-relationship.html#relatedto" title="relatedto">is related to</a></td><td>DeviceUseStatement.indication</td><td>Element `DeviceUsage.reason` is mapped to FHIR STU3 element `DeviceUseStatement.indication` as `SourceIsBroaderThanTarget`.
The mappings for `DeviceUsage.reason` do not cover the following types: CodeableReference.
When the status is not done, the reason code indicates why it was not done.</td></tr><tr><td>DeviceUsage.bodySite (bodySite)</td><td><a href="CodeSystem-concept-map-relationship.html#wider" title="wider">maps to wider concept</a></td><td>DeviceUseStatement.bodySite</td><td>Element `DeviceUsage.bodySite` is mapped to FHIR STU3 element `DeviceUseStatement.bodySite` as `SourceIsBroaderThanTarget`.
The mappings for `DeviceUsage.bodySite` do not cover the following types: CodeableReference.
The mappings for `DeviceUsage.bodySite` do not cover the following types based on type expansion: reference.</td></tr><tr><td>DeviceUsage.note (note)</td><td><a href="CodeSystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>DeviceUseStatement.note</td><td>Element `DeviceUsage.note` is mapped to FHIR STU3 element `DeviceUseStatement.note` as `Equivalent`.</td></tr></table><hr/><p><b>Group 2 </b>Mapping from <code>http://hl7.org/fhir/StructureDefinition/DeviceUsage|5.0.0</code> to <a href="StructureDefinition-ext-R5-DeviceUsage.basedOn.html">R5: Fulfills plan, proposal or order (new)version: 0.1.0)</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>DeviceUsage.basedOn (basedOn)</td><td><a href="CodeSystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Extension (R5: Fulfills plan, proposal or order (new))</td><td>Element `DeviceUsage.basedOn` has a context of DeviceUseStatement based on following the parent source element upwards and mapping to `DeviceUseStatement`.
Element `DeviceUsage.basedOn` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).</td></tr></table><hr/><p><b>Group 3 </b>Mapping from <code>http://hl7.org/fhir/StructureDefinition/DeviceUsage|5.0.0</code> to <a href="StructureDefinition-ext-R5-DeviceUsage.status.html">R5: active | completed | not-done | entered-in-error +version: 0.1.0)</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>DeviceUsage.status (status)</td><td><a href="CodeSystem-concept-map-relationship.html#wider" title="wider">maps to wider concept</a></td><td>Extension (R5: active | completed | not-done | entered-in-error +)</td><td>Element `DeviceUsage.status` is mapped to FHIR STU3 element `DeviceUseStatement.status` as `SourceIsBroaderThanTarget`.
The target context `DeviceUseStatement.status` is a modifier element, so this extension does not need to be defined as a modifier.
DeviceUseStatment is a statement at a point in time.  The status is only representative at the point when it was asserted.  The value set for contains codes that assert the status of the use  by the patient (for example, stopped or on hold) as well as codes that assert the status of the resource itself (for example, entered in error).

This element is labeled as a modifier because the status contains the codes that mark the statement as not currently valid.</td></tr></table><hr/><p><b>Group 4 </b>Mapping from <code>http://hl7.org/fhir/StructureDefinition/DeviceUsage|5.0.0</code> to <a href="StructureDefinition-ext-R5-DeviceUsage.category.html">R5: The category of the statement - classifying how the statement is made (new)version: 0.1.0)</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>DeviceUsage.category (category)</td><td><a href="CodeSystem-concept-map-relationship.html#wider" title="wider">maps to wider concept</a></td><td>Extension (R5: The category of the statement - classifying how the statement is made (new))</td><td>Element `DeviceUsage.category` has a context of DeviceUseStatement based on following the parent source element upwards and mapping to `DeviceUseStatement`.
Element `DeviceUsage.category` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).</td></tr></table><hr/><p><b>Group 5 </b>Mapping from <code>http://hl7.org/fhir/StructureDefinition/DeviceUsage|5.0.0</code> to <a href="StructureDefinition-ext-R5-DeviceUsage.derivedFrom.html">R5: Supporting information (new)version: 0.1.0)</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>DeviceUsage.derivedFrom (derivedFrom)</td><td><a href="CodeSystem-concept-map-relationship.html#wider" title="wider">maps to wider concept</a></td><td>Extension (R5: Supporting information (new))</td><td>Element `DeviceUsage.derivedFrom` has a context of DeviceUseStatement based on following the parent source element upwards and mapping to `DeviceUseStatement`.
Element `DeviceUsage.derivedFrom` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).
The most common use cases for deriving a DeviceUsage comes from creating it from a request or from an observation or a claim. it should be noted that the amount of information that is available varies from the type resource that you derive the DeviceUsage from.</td></tr></table><hr/><p><b>Group 6 </b>Mapping from <code>http://hl7.org/fhir/StructureDefinition/DeviceUsage|5.0.0</code> to <a href="StructureDefinition-ext-R5-DeviceUsage.context.html">R5: The encounter or episode of care that establishes the context for this device use statement (new)version: 0.1.0)</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>DeviceUsage.context (context)</td><td><a href="CodeSystem-concept-map-relationship.html#wider" title="wider">maps to wider concept</a></td><td>Extension (R5: The encounter or episode of care that establishes the context for this device use statement (new))</td><td>Element `DeviceUsage.context` has a context of DeviceUseStatement based on following the parent source element upwards and mapping to `DeviceUseStatement`.
Element `DeviceUsage.context` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).</td></tr></table><hr/><p><b>Group 7 </b>Mapping from <code>http://hl7.org/fhir/StructureDefinition/DeviceUsage|5.0.0</code> to <a href="StructureDefinition-ext-R5-DeviceUsage.usageStatus.html">R5: The status of the device usage, for example always, sometimes, never. This is not the same as the status of the statement (new)version: 0.1.0)</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>DeviceUsage.usageStatus (usageStatus)</td><td><a href="CodeSystem-concept-map-relationship.html#wider" title="wider">maps to wider concept</a></td><td>Extension (R5: The status of the device usage, for example always, sometimes, never. This is not the same as the status of the statement (new))</td><td>Element `DeviceUsage.usageStatus` has a context of DeviceUseStatement based on following the parent source element upwards and mapping to `DeviceUseStatement`.
Element `DeviceUsage.usageStatus` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).</td></tr></table><hr/><p><b>Group 8 </b>Mapping from <code>http://hl7.org/fhir/StructureDefinition/DeviceUsage|5.0.0</code> to <a href="StructureDefinition-ext-R5-DeviceUsage.usageReason.html">R5: The reason for asserting the usage status - for example forgot, lost, stolen, broken (new)version: 0.1.0)</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>DeviceUsage.usageReason (usageReason)</td><td><a href="CodeSystem-concept-map-relationship.html#wider" title="wider">maps to wider concept</a></td><td>Extension (R5: The reason for asserting the usage status - for example forgot, lost, stolen, broken (new))</td><td>Element `DeviceUsage.usageReason` has a context of DeviceUseStatement based on following the parent source element upwards and mapping to `DeviceUseStatement`.
Element `DeviceUsage.usageReason` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).</td></tr></table><hr/><p><b>Group 9 </b>Mapping from <code>http://hl7.org/fhir/StructureDefinition/DeviceUsage|5.0.0</code> to <a href="StructureDefinition-ext-R5-DeviceUsage.adherence.html">R5: How device is being used (new)version: 0.1.0)</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>DeviceUsage.adherence (adherence)</td><td><a href="CodeSystem-concept-map-relationship.html#wider" title="wider">maps to wider concept</a></td><td>Extension (R5: How device is being used (new))</td><td>Element `DeviceUsage.adherence` has a context of DeviceUseStatement based on following the parent source element upwards and mapping to `DeviceUseStatement`.
Element `DeviceUsage.adherence` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).</td></tr><tr><td>DeviceUsage.adherence.code (code)</td><td><a href="CodeSystem-concept-map-relationship.html#wider" title="wider">maps to wider concept</a></td><td>Extension.extension:code (R5: always | never | sometimes (new))</td><td>Element `DeviceUsage.adherence.code` is part of an existing definition because parent element `DeviceUsage.adherence` requires a cross-version extension.
Element `DeviceUsage.adherence.code` has a context of DeviceUseStatement based on following the parent source element upwards and mapping to `DeviceUseStatement`.
Element `DeviceUsage.adherence.code` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).</td></tr><tr><td>DeviceUsage.adherence.reason (reason)</td><td><a href="CodeSystem-concept-map-relationship.html#wider" title="wider">maps to wider concept</a></td><td>Extension.extension:reason (R5: lost | stolen | prescribed | broken | burned | forgot (new))</td><td>Element `DeviceUsage.adherence.reason` is part of an existing definition because parent element `DeviceUsage.adherence` requires a cross-version extension.
Element `DeviceUsage.adherence.reason` has a context of DeviceUseStatement based on following the parent source element upwards and mapping to `DeviceUseStatement`.
Element `DeviceUsage.adherence.reason` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).</td></tr></table><hr/><p><b>Group 10 </b>Mapping from <code>http://hl7.org/fhir/StructureDefinition/DeviceUsage|5.0.0</code> to <a href="StructureDefinition-ext-R5-DeviceUsage.device.html">R5: Code or Reference to device used additional typesversion: 0.1.0)</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>DeviceUsage.device (device)</td><td><a href="CodeSystem-concept-map-relationship.html#wider" title="wider">maps to wider concept</a></td><td>Extension (R5: Code or Reference to device used additional types)</td><td>Element `DeviceUsage.device` is mapped to FHIR STU3 element `DeviceUseStatement.device` as `SourceIsBroaderThanTarget`.
The mappings for `DeviceUsage.device` do not cover the following types: CodeableReference.
The mappings for `DeviceUsage.device` do not cover the following types based on type expansion: concept.</td></tr></table><hr/><p><b>Group 11 </b>Mapping from <code>http://hl7.org/fhir/StructureDefinition/DeviceUsage|5.0.0</code> to <a href="StructureDefinition-ext-R5-DeviceUsage.reason.html">R5: reason additional typesversion: 0.1.0)</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>DeviceUsage.reason (reason)</td><td><a href="CodeSystem-concept-map-relationship.html#wider" title="wider">maps to wider concept</a></td><td>Extension (R5: reason additional types)</td><td>Element `DeviceUsage.reason` is mapped to FHIR STU3 element `DeviceUseStatement.indication` as `SourceIsBroaderThanTarget`.
The mappings for `DeviceUsage.reason` do not cover the following types: CodeableReference.
When the status is not done, the reason code indicates why it was not done.</td></tr></table><hr/><p><b>Group 12 </b>Mapping from <code>http://hl7.org/fhir/StructureDefinition/DeviceUsage|5.0.0</code> to <a href="StructureDefinition-ext-R5-DeviceUsage.bodySite.html">R5: bodySite additional typesversion: 0.1.0)</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>DeviceUsage.bodySite (bodySite)</td><td><a href="CodeSystem-concept-map-relationship.html#wider" title="wider">maps to wider concept</a></td><td>Extension (R5: bodySite additional types)</td><td>Element `DeviceUsage.bodySite` is mapped to FHIR STU3 element `DeviceUseStatement.bodySite` as `SourceIsBroaderThanTarget`.
The mappings for `DeviceUsage.bodySite` do not cover the following types: CodeableReference.
The mappings for `DeviceUsage.bodySite` do not cover the following types based on type expansion: reference.</td></tr></table></div>
  </text>
  <extension
             url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
    <valueCode value="fhir"/>
  </extension>
  <extension
             url="http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm">
    <valueInteger value="0">
      <extension
                 url="http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom">
        <valueUri
                  value="http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r5.r3"/>
      </extension>
    </valueInteger>
  </extension>
  <extension
             url="http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status">
    <valueCode value="trial-use">
      <extension
                 url="http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom">
        <valueUri
                  value="http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r5.r3"/>
      </extension>
    </valueCode>
  </extension>
  <url
       value="http://hl7.org/fhir/uv/xver/ConceptMap/R5-DeviceUsage-element-map-to-R3"/>
  <version value="0.1.0"/>
  <name value="R5DeviceUsageElementMapToR3"/>
  <title
         value="Cross-version mapping for FHIR R5 DeviceUsage to FHIR STU3 DeviceUseStatement"/>
  <status value="active"/>
  <experimental value="false"/>
  <date value="2026-03-17T16:05:15.6126395-05:00"/>
  <contact>
    <name value="FHIR Infrastructure"/>
    <telecom>
      <system value="url"/>
      <value value="http://www.hl7.org/Special/committees/fiwg"/>
    </telecom>
  </contact>
  <description
               value="This ConceptMap represents cross-version mappings for elements from a FHIR R5 DeviceUsage to FHIR STU3."/>
  <jurisdiction>
    <coding>
      <system value="http://unstats.un.org/unsd/methods/m49/m49.htm"/>
      <code value="001"/>
      <display value="World"/>
    </coding>
  </jurisdiction>
  <sourceUri value="http://hl7.org/fhir/5.0"/>
  <targetUri value="http://hl7.org/fhir/3.0"/>
  <group>
    <source value="http://hl7.org/fhir/StructureDefinition/DeviceUsage"/>
    <sourceVersion value="5.0.0"/>
    <target
            value="http://hl7.org/fhir/StructureDefinition/DeviceUseStatement"/>
    <targetVersion value="3.0.2"/>
    <element>
      <code value="DeviceUsage.meta"/>
      <display value="meta"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="equivalent"/>
        </modifierExtension>
        <code value="DeviceUseStatement.meta"/>
        <display value="DeviceUseStatement.meta"/>
        <equivalence value="equivalent"/>
        <comment
                 value="Element `DeviceUsage.meta` is mapped to FHIR STU3 element `DeviceUseStatement.meta` as `Equivalent`."/>
      </target>
    </element>
    <element>
      <code value="DeviceUsage.implicitRules"/>
      <display value="implicitRules"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="equivalent"/>
        </modifierExtension>
        <code value="DeviceUseStatement.implicitRules"/>
        <display value="DeviceUseStatement.implicitRules"/>
        <equivalence value="equivalent"/>
        <comment
                 value="Element `DeviceUsage.implicitRules` is mapped to FHIR STU3 element `DeviceUseStatement.implicitRules` as `Equivalent`.
Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of its narrative along with other profiles, value sets, etc."/>
      </target>
    </element>
    <element>
      <code value="DeviceUsage.language"/>
      <display value="language"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="equivalent"/>
        </modifierExtension>
        <code value="DeviceUseStatement.language"/>
        <display value="DeviceUseStatement.language"/>
        <equivalence value="equivalent"/>
        <comment
                 value="Element `DeviceUsage.language` is mapped to FHIR STU3 element `DeviceUseStatement.language` as `Equivalent`.
Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies  to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute)."/>
      </target>
    </element>
    <element>
      <code value="DeviceUsage.text"/>
      <display value="text"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="equivalent"/>
        </modifierExtension>
        <code value="DeviceUseStatement.text"/>
        <display value="DeviceUseStatement.text"/>
        <equivalence value="equivalent"/>
        <comment
                 value="Element `DeviceUsage.text` is mapped to FHIR STU3 element `DeviceUseStatement.text` as `Equivalent`.
Contained resources do not have a narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied).  This may be necessary for data from legacy systems where information is captured as a &quot;text blob&quot; or where text is additionally entered raw or narrated and encoded information is added later."/>
      </target>
    </element>
    <element>
      <code value="DeviceUsage.contained"/>
      <display value="contained"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="equivalent"/>
        </modifierExtension>
        <code value="DeviceUseStatement.contained"/>
        <display value="DeviceUseStatement.contained"/>
        <equivalence value="equivalent"/>
        <comment
                 value="Element `DeviceUsage.contained` is mapped to FHIR STU3 element `DeviceUseStatement.contained` as `SourceIsBroaderThanTarget`.
This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags in their meta elements, but SHALL NOT have security labels."/>
      </target>
    </element>
    <element>
      <code value="DeviceUsage.identifier"/>
      <display value="identifier"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="equivalent"/>
        </modifierExtension>
        <code value="DeviceUseStatement.identifier"/>
        <display value="DeviceUseStatement.identifier"/>
        <equivalence value="equivalent"/>
        <comment
                 value="Element `DeviceUsage.identifier` is mapped to FHIR STU3 element `DeviceUseStatement.identifier` as `Equivalent`."/>
      </target>
    </element>
    <element>
      <code value="DeviceUsage.status"/>
      <display value="status"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="wider"/>
        </modifierExtension>
        <code value="DeviceUseStatement.status"/>
        <display value="DeviceUseStatement.status"/>
        <equivalence value="wider"/>
        <comment
                 value="Element `DeviceUsage.status` is mapped to FHIR STU3 element `DeviceUseStatement.status` as `SourceIsBroaderThanTarget`.
The target context `DeviceUseStatement.status` is a modifier element, so this extension does not need to be defined as a modifier.
DeviceUseStatment is a statement at a point in time.  The status is only representative at the point when it was asserted.  The value set for contains codes that assert the status of the use  by the patient (for example, stopped or on hold) as well as codes that assert the status of the resource itself (for example, entered in error).

This element is labeled as a modifier because the status contains the codes that mark the statement as not currently valid."/>
      </target>
    </element>
    <element>
      <code value="DeviceUsage.patient"/>
      <display value="patient"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="wider"/>
        </modifierExtension>
        <code value="DeviceUseStatement.subject"/>
        <display value="DeviceUseStatement.subject"/>
        <equivalence value="wider"/>
        <comment
                 value="Element `DeviceUsage.patient` is mapped to FHIR STU3 element `DeviceUseStatement.subject` as `SourceIsBroaderThanTarget`.
The mappings for `DeviceUsage.patient` do not cover the following types based on type expansion: display, identifier, reference, type.
The standard extension `alternate-reference` has been mapped as the representation of FHIR R5 element `DeviceUsage.patient` with unmapped reference targets: Patient."/>
      </target>
    </element>
    <element>
      <code value="DeviceUsage.timing[x]"/>
      <display value="timing[x]"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="equivalent"/>
        </modifierExtension>
        <code value="DeviceUseStatement.timing[x]"/>
        <display value="DeviceUseStatement.timing[x]"/>
        <equivalence value="equivalent"/>
        <comment
                 value="Element `DeviceUsage.timing[x]` is mapped to FHIR STU3 element `DeviceUseStatement.timing[x]` as `Equivalent`.
The target context `DeviceUseStatement.timing[x]` is a choice-type element and cannot directly hold extensions. The context is moved up to parent element `DeviceUseStatement`."/>
      </target>
    </element>
    <element>
      <code value="DeviceUsage.dateAsserted"/>
      <display value="dateAsserted"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="equivalent"/>
        </modifierExtension>
        <code value="DeviceUseStatement.recordedOn"/>
        <display value="DeviceUseStatement.recordedOn"/>
        <equivalence value="equivalent"/>
        <comment
                 value="Element `DeviceUsage.dateAsserted` is mapped to FHIR STU3 element `DeviceUseStatement.recordedOn` as `Equivalent`."/>
      </target>
    </element>
    <element>
      <code value="DeviceUsage.informationSource"/>
      <display value="informationSource"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="wider"/>
        </modifierExtension>
        <code value="DeviceUseStatement.source"/>
        <display value="DeviceUseStatement.source"/>
        <equivalence value="wider"/>
        <comment
                 value="Element `DeviceUsage.informationSource` is mapped to FHIR STU3 element `DeviceUseStatement.source` as `SourceIsBroaderThanTarget`.
The standard extension `alternate-reference` has been mapped as the representation of FHIR R5 element `DeviceUsage.informationSource` with unmapped reference targets: Organization, Patient, Practitioner, PractitionerRole, RelatedPerson."/>
      </target>
    </element>
    <element>
      <code value="DeviceUsage.device"/>
      <display value="device"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="wider"/>
        </modifierExtension>
        <code value="DeviceUseStatement.device"/>
        <display value="DeviceUseStatement.device"/>
        <equivalence value="wider"/>
        <comment
                 value="Element `DeviceUsage.device` is mapped to FHIR STU3 element `DeviceUseStatement.device` as `SourceIsBroaderThanTarget`.
The mappings for `DeviceUsage.device` do not cover the following types: CodeableReference.
The mappings for `DeviceUsage.device` do not cover the following types based on type expansion: concept."/>
      </target>
    </element>
    <element>
      <code value="DeviceUsage.reason"/>
      <display value="reason"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="relatedto"/>
        </modifierExtension>
        <code value="DeviceUseStatement.indication"/>
        <display value="DeviceUseStatement.indication"/>
        <equivalence value="relatedto"/>
        <comment
                 value="Element `DeviceUsage.reason` is mapped to FHIR STU3 element `DeviceUseStatement.indication` as `SourceIsBroaderThanTarget`.
The mappings for `DeviceUsage.reason` do not cover the following types: CodeableReference.
When the status is not done, the reason code indicates why it was not done."/>
      </target>
    </element>
    <element>
      <code value="DeviceUsage.bodySite"/>
      <display value="bodySite"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="wider"/>
        </modifierExtension>
        <code value="DeviceUseStatement.bodySite"/>
        <display value="DeviceUseStatement.bodySite"/>
        <equivalence value="wider"/>
        <comment
                 value="Element `DeviceUsage.bodySite` is mapped to FHIR STU3 element `DeviceUseStatement.bodySite` as `SourceIsBroaderThanTarget`.
The mappings for `DeviceUsage.bodySite` do not cover the following types: CodeableReference.
The mappings for `DeviceUsage.bodySite` do not cover the following types based on type expansion: reference."/>
      </target>
    </element>
    <element>
      <code value="DeviceUsage.note"/>
      <display value="note"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="equivalent"/>
        </modifierExtension>
        <code value="DeviceUseStatement.note"/>
        <display value="DeviceUseStatement.note"/>
        <equivalence value="equivalent"/>
        <comment
                 value="Element `DeviceUsage.note` is mapped to FHIR STU3 element `DeviceUseStatement.note` as `Equivalent`."/>
      </target>
    </element>
  </group>
  <group>
    <source value="http://hl7.org/fhir/StructureDefinition/DeviceUsage"/>
    <sourceVersion value="5.0.0"/>
    <target
            value="http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceUsage.basedOn"/>
    <targetVersion value="0.1.0"/>
    <element>
      <code value="DeviceUsage.basedOn"/>
      <display value="basedOn"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="equivalent"/>
        </modifierExtension>
        <code value="Extension"/>
        <equivalence value="equivalent"/>
        <comment
                 value="Element `DeviceUsage.basedOn` has a context of DeviceUseStatement based on following the parent source element upwards and mapping to `DeviceUseStatement`.
Element `DeviceUsage.basedOn` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."/>
      </target>
    </element>
  </group>
  <group>
    <source value="http://hl7.org/fhir/StructureDefinition/DeviceUsage"/>
    <sourceVersion value="5.0.0"/>
    <target
            value="http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceUsage.status"/>
    <targetVersion value="0.1.0"/>
    <element>
      <code value="DeviceUsage.status"/>
      <display value="status"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="wider"/>
        </modifierExtension>
        <code value="Extension"/>
        <equivalence value="wider"/>
        <comment
                 value="Element `DeviceUsage.status` is mapped to FHIR STU3 element `DeviceUseStatement.status` as `SourceIsBroaderThanTarget`.
The target context `DeviceUseStatement.status` is a modifier element, so this extension does not need to be defined as a modifier.
DeviceUseStatment is a statement at a point in time.  The status is only representative at the point when it was asserted.  The value set for contains codes that assert the status of the use  by the patient (for example, stopped or on hold) as well as codes that assert the status of the resource itself (for example, entered in error).

This element is labeled as a modifier because the status contains the codes that mark the statement as not currently valid."/>
      </target>
    </element>
  </group>
  <group>
    <source value="http://hl7.org/fhir/StructureDefinition/DeviceUsage"/>
    <sourceVersion value="5.0.0"/>
    <target
            value="http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceUsage.category"/>
    <targetVersion value="0.1.0"/>
    <element>
      <code value="DeviceUsage.category"/>
      <display value="category"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="wider"/>
        </modifierExtension>
        <code value="Extension"/>
        <equivalence value="wider"/>
        <comment
                 value="Element `DeviceUsage.category` has a context of DeviceUseStatement based on following the parent source element upwards and mapping to `DeviceUseStatement`.
Element `DeviceUsage.category` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."/>
      </target>
    </element>
  </group>
  <group>
    <source value="http://hl7.org/fhir/StructureDefinition/DeviceUsage"/>
    <sourceVersion value="5.0.0"/>
    <target
            value="http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceUsage.derivedFrom"/>
    <targetVersion value="0.1.0"/>
    <element>
      <code value="DeviceUsage.derivedFrom"/>
      <display value="derivedFrom"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="wider"/>
        </modifierExtension>
        <code value="Extension"/>
        <equivalence value="wider"/>
        <comment
                 value="Element `DeviceUsage.derivedFrom` has a context of DeviceUseStatement based on following the parent source element upwards and mapping to `DeviceUseStatement`.
Element `DeviceUsage.derivedFrom` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).
The most common use cases for deriving a DeviceUsage comes from creating it from a request or from an observation or a claim. it should be noted that the amount of information that is available varies from the type resource that you derive the DeviceUsage from."/>
      </target>
    </element>
  </group>
  <group>
    <source value="http://hl7.org/fhir/StructureDefinition/DeviceUsage"/>
    <sourceVersion value="5.0.0"/>
    <target
            value="http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceUsage.context"/>
    <targetVersion value="0.1.0"/>
    <element>
      <code value="DeviceUsage.context"/>
      <display value="context"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="wider"/>
        </modifierExtension>
        <code value="Extension"/>
        <equivalence value="wider"/>
        <comment
                 value="Element `DeviceUsage.context` has a context of DeviceUseStatement based on following the parent source element upwards and mapping to `DeviceUseStatement`.
Element `DeviceUsage.context` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."/>
      </target>
    </element>
  </group>
  <group>
    <source value="http://hl7.org/fhir/StructureDefinition/DeviceUsage"/>
    <sourceVersion value="5.0.0"/>
    <target
            value="http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceUsage.usageStatus"/>
    <targetVersion value="0.1.0"/>
    <element>
      <code value="DeviceUsage.usageStatus"/>
      <display value="usageStatus"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="wider"/>
        </modifierExtension>
        <code value="Extension"/>
        <equivalence value="wider"/>
        <comment
                 value="Element `DeviceUsage.usageStatus` has a context of DeviceUseStatement based on following the parent source element upwards and mapping to `DeviceUseStatement`.
Element `DeviceUsage.usageStatus` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."/>
      </target>
    </element>
  </group>
  <group>
    <source value="http://hl7.org/fhir/StructureDefinition/DeviceUsage"/>
    <sourceVersion value="5.0.0"/>
    <target
            value="http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceUsage.usageReason"/>
    <targetVersion value="0.1.0"/>
    <element>
      <code value="DeviceUsage.usageReason"/>
      <display value="usageReason"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="wider"/>
        </modifierExtension>
        <code value="Extension"/>
        <equivalence value="wider"/>
        <comment
                 value="Element `DeviceUsage.usageReason` has a context of DeviceUseStatement based on following the parent source element upwards and mapping to `DeviceUseStatement`.
Element `DeviceUsage.usageReason` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."/>
      </target>
    </element>
  </group>
  <group>
    <source value="http://hl7.org/fhir/StructureDefinition/DeviceUsage"/>
    <sourceVersion value="5.0.0"/>
    <target
            value="http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceUsage.adherence"/>
    <targetVersion value="0.1.0"/>
    <element>
      <code value="DeviceUsage.adherence"/>
      <display value="adherence"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="wider"/>
        </modifierExtension>
        <code value="Extension"/>
        <equivalence value="wider"/>
        <comment
                 value="Element `DeviceUsage.adherence` has a context of DeviceUseStatement based on following the parent source element upwards and mapping to `DeviceUseStatement`.
Element `DeviceUsage.adherence` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."/>
      </target>
    </element>
    <element>
      <code value="DeviceUsage.adherence.code"/>
      <display value="code"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="wider"/>
        </modifierExtension>
        <code value="Extension.extension:code"/>
        <equivalence value="wider"/>
        <comment
                 value="Element `DeviceUsage.adherence.code` is part of an existing definition because parent element `DeviceUsage.adherence` requires a cross-version extension.
Element `DeviceUsage.adherence.code` has a context of DeviceUseStatement based on following the parent source element upwards and mapping to `DeviceUseStatement`.
Element `DeviceUsage.adherence.code` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."/>
      </target>
    </element>
    <element>
      <code value="DeviceUsage.adherence.reason"/>
      <display value="reason"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="wider"/>
        </modifierExtension>
        <code value="Extension.extension:reason"/>
        <equivalence value="wider"/>
        <comment
                 value="Element `DeviceUsage.adherence.reason` is part of an existing definition because parent element `DeviceUsage.adherence` requires a cross-version extension.
Element `DeviceUsage.adherence.reason` has a context of DeviceUseStatement based on following the parent source element upwards and mapping to `DeviceUseStatement`.
Element `DeviceUsage.adherence.reason` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."/>
      </target>
    </element>
  </group>
  <group>
    <source value="http://hl7.org/fhir/StructureDefinition/DeviceUsage"/>
    <sourceVersion value="5.0.0"/>
    <target
            value="http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceUsage.device"/>
    <targetVersion value="0.1.0"/>
    <element>
      <code value="DeviceUsage.device"/>
      <display value="device"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="wider"/>
        </modifierExtension>
        <code value="Extension"/>
        <equivalence value="wider"/>
        <comment
                 value="Element `DeviceUsage.device` is mapped to FHIR STU3 element `DeviceUseStatement.device` as `SourceIsBroaderThanTarget`.
The mappings for `DeviceUsage.device` do not cover the following types: CodeableReference.
The mappings for `DeviceUsage.device` do not cover the following types based on type expansion: concept."/>
      </target>
    </element>
  </group>
  <group>
    <source value="http://hl7.org/fhir/StructureDefinition/DeviceUsage"/>
    <sourceVersion value="5.0.0"/>
    <target
            value="http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceUsage.reason"/>
    <targetVersion value="0.1.0"/>
    <element>
      <code value="DeviceUsage.reason"/>
      <display value="reason"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="wider"/>
        </modifierExtension>
        <code value="Extension"/>
        <equivalence value="wider"/>
        <comment
                 value="Element `DeviceUsage.reason` is mapped to FHIR STU3 element `DeviceUseStatement.indication` as `SourceIsBroaderThanTarget`.
The mappings for `DeviceUsage.reason` do not cover the following types: CodeableReference.
When the status is not done, the reason code indicates why it was not done."/>
      </target>
    </element>
  </group>
  <group>
    <source value="http://hl7.org/fhir/StructureDefinition/DeviceUsage"/>
    <sourceVersion value="5.0.0"/>
    <target
            value="http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceUsage.bodySite"/>
    <targetVersion value="0.1.0"/>
    <element>
      <code value="DeviceUsage.bodySite"/>
      <display value="bodySite"/>
      <target>
        <modifierExtension
                           url="http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence">
          <valueCode value="wider"/>
        </modifierExtension>
        <code value="Extension"/>
        <equivalence value="wider"/>
        <comment
                 value="Element `DeviceUsage.bodySite` is mapped to FHIR STU3 element `DeviceUseStatement.bodySite` as `SourceIsBroaderThanTarget`.
The mappings for `DeviceUsage.bodySite` do not cover the following types: CodeableReference.
The mappings for `DeviceUsage.bodySite` do not cover the following types based on type expansion: reference."/>
      </target>
    </element>
  </group>
</ConceptMap>