Extensions for Using Data Elements from FHIR R4B in FHIR STU3 - Downloaded Version null See the Directory of published versions
| Official URL: http://hl7.org/fhir/uv/xver/ValueSet/R4B-v2-0003-for-R3 | Version: 0.1.0 | |||
| Standards status: Trial-use | Maturity Level: 0 | Computable Name: R4BV20003ForR3 | ||
| This cross-version ValueSet represents content from http://terminology.hl7.org/ValueSet/v2-0003 | 2.0.0 for use in FHIR STU3 that is appropriate for use but unavailable in http://hl7.org/fhir/ValueSet/v2-0003|2.8.2. |
This value set is part of the cross-version definitions generated to enable use of the
value set http://terminology.hl7.org/ValueSet/v2-0003|2.0.0 as defined in FHIR R4B
in FHIR STU3.
The source value set is bound to the following FHIR R4B elements:
SubscriptionTopic.eventTrigger.event as ExampleAcross FHIR versions, the value set has been mapped as:
http://terminology.hl7.org/ValueSet/v2-0003|2.0.0http://terminology.hl7.org/ValueSet/v2-0003|2.9http://hl7.org/fhir/ValueSet/v2-0003|2.8.2Note that there are 368 concepts not included in this cross-version definition because they have valid representations.
Following are the generation technical comments: All concepts in the comparison are listed as identical. The source value set has more active concepts (384) than the target (368), so the source is broader than the target. All concepts in the comparison are have code literals listed as identical. The source value set has more active concepts (368) than the target (354), so the source is broader than the target.
References
http://terminology.hl7.org/CodeSystem/v2-0003 version 📍2.0.0| Code | Display |
| S38 | Containers Prepared for Specimen Collection |
| S39 | Specimen Collection Successful |
| S40 | Specimen Collection Unsuccessful |
| S41 | Specimen Departed |
| S42 | Specimen Arrived |
| S43 | Specimen Accepted |
| S44 | Specimen Rejected |
| S45 | Specimen Re-identified |
| S46 | Specimen De-identified |
| S47 | Specimen Sent to Archive |
| S48 | Specimen Retrieved from Archive |
| S49 | Specimen Disposed of |
| S50 | Specimen Procedure Step Successful , with Derived Specimen(s) |
| S51 | Specimen Procedure Step Successful, no Derived Specimen(s) |
| S52 | Specimen Procedure Step Unsuccessful |
| varies | MFQ/MFR - Master files query (use event same as asking for e.g., M05 - location) |
This value set expansion contains 16 concepts.
Explanation of the columns that may appear on this page:
| Level | A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies |
| System | The source of the definition of the code (when the value set draws in codes defined elsewhere) |
| Code | The code (used as the code in the resource instance) |
| Display | The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application |
| Definition | An explanation of the meaning of the concept |
| Comments | Additional notes about how to use the code |