ValueSet: Cross-version VS for R4.v3.EntityHandling for use in FHIR R4B

Official URL: http://hl7.org/fhir/4.0/ValueSet/R4-v3-EntityHandling-for-R4B Version: 0.0.1-snapshot-2
Standards status: Informative Maturity Level: 0 Responsible: HL7 International / Terminology Infrastructure Computable Name: R4_v3_EntityHandling_for_R4B

This cross-version ValueSet represents concepts from http://terminology.hl7.org/ValueSet/v3-EntityHandling 2018-08-12 for use in FHIR R4B. Concepts not present here have direct equivalent mappings crossing all versions from R4 to R4B.

References

This value set is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)

Logical Definition (CLD)

  • Include these codes as defined in http://terminology.hl7.org/CodeSystem/v3-EntityHandling version 2018-08-12
    CodeDisplayDefinition
    AMBAmbient TemperatureKeep at ambient temperature, 22 +/- 2C
    C37Body TemperatureCritical to keep at body temperature 36-38C
    CAMBCritical Ambient temperatureCritical ambient - must not be refrigerated or frozen.
    CATMProtect from AirCritical. Do not expose to atmosphere. Do not uncap.
    CFRZCritical frozenCritical frozen. Specimen must not be allowed to thaw until immediately prior to testing.
    CREFCritical refrigerated temperatureCritical refrigerated - must not be allowed to freeze or warm until imediately prior to testing.
    DFRZDeep FrozenDeep Frozen -16 to -20C.
    DRYdryKeep in a dry environment
    FRZfrozenKeep frozen below 0 ?C
    MTLFMetal FreeContainer is free of heavy metals, including lead.
    NTRnitrogenKeep in liquid nitrogen
    PRTLProtect from LightProtect from light (eg. Wrap in aluminum foil).
    PSAdo not shakeDo not shake
    PSOno shockProtect against shock
    REFRefrigerated temperatureKeep at refrigerated temperature:4-8C Accidental warming or freezing is of little consequence.
    SBUShake before useShake thoroughly before using
    UFRZUltra frozenUltra cold frozen -75 to -85C. Ultra cold freezer is typically at temperature of dry ice.
    UPRuprightKeep upright, do not turn upside down

 

Expansion

This value set expansion contains 18 concepts.

CodeSystemDisplayDefinition
  AMBhttp://terminology.hl7.org/CodeSystem/v3-EntityHandlingAmbient TemperatureKeep at ambient temperature, 22 +/- 2C
  C37http://terminology.hl7.org/CodeSystem/v3-EntityHandlingBody TemperatureCritical to keep at body temperature 36-38C
  CAMBhttp://terminology.hl7.org/CodeSystem/v3-EntityHandlingCritical Ambient temperatureCritical ambient - must not be refrigerated or frozen.
  CATMhttp://terminology.hl7.org/CodeSystem/v3-EntityHandlingProtect from AirCritical. Do not expose to atmosphere. Do not uncap.
  CFRZhttp://terminology.hl7.org/CodeSystem/v3-EntityHandlingCritical frozenCritical frozen. Specimen must not be allowed to thaw until immediately prior to testing.
  CREFhttp://terminology.hl7.org/CodeSystem/v3-EntityHandlingCritical refrigerated temperatureCritical refrigerated - must not be allowed to freeze or warm until imediately prior to testing.
  DFRZhttp://terminology.hl7.org/CodeSystem/v3-EntityHandlingDeep FrozenDeep Frozen -16 to -20C.
  DRYhttp://terminology.hl7.org/CodeSystem/v3-EntityHandlingdryKeep in a dry environment
  FRZhttp://terminology.hl7.org/CodeSystem/v3-EntityHandlingfrozenKeep frozen below 0 ?C
  MTLFhttp://terminology.hl7.org/CodeSystem/v3-EntityHandlingMetal FreeContainer is free of heavy metals, including lead.
  NTRhttp://terminology.hl7.org/CodeSystem/v3-EntityHandlingnitrogenKeep in liquid nitrogen
  PRTLhttp://terminology.hl7.org/CodeSystem/v3-EntityHandlingProtect from LightProtect from light (eg. Wrap in aluminum foil).
  PSAhttp://terminology.hl7.org/CodeSystem/v3-EntityHandlingdo not shakeDo not shake
  PSOhttp://terminology.hl7.org/CodeSystem/v3-EntityHandlingno shockProtect against shock
  REFhttp://terminology.hl7.org/CodeSystem/v3-EntityHandlingRefrigerated temperatureKeep at refrigerated temperature:4-8C Accidental warming or freezing is of little consequence.
  SBUhttp://terminology.hl7.org/CodeSystem/v3-EntityHandlingShake before useShake thoroughly before using
  UFRZhttp://terminology.hl7.org/CodeSystem/v3-EntityHandlingUltra frozenUltra cold frozen -75 to -85C. Ultra cold freezer is typically at temperature of dry ice.
  UPRhttp://terminology.hl7.org/CodeSystem/v3-EntityHandlinguprightKeep upright, do not turn upside down

Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code