FHIR Cross-Version Extensions package for FHIR R4B from FHIR R4
0.0.1-snapshot-2 - informative International flag

FHIR Cross-Version Extensions package for FHIR R4B from FHIR R4 - Version 0.0.1-snapshot-2. See the Directory of published versions

: v3 Code System EntityHandling - XML Representation

Page standards status: External Maturity Level: 0

Raw xml | Download


<CodeSystem xmlns="http://hl7.org/fhir">
  <id value="v3-EntityHandling"/>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: CodeSystem v3-EntityHandling</b></p><a name="v3-EntityHandling"> </a><a name="hcv3-EntityHandling"> </a><p>This case-sensitive code system <code>http://terminology.hl7.org/CodeSystem/v3-EntityHandling</code> defines the following codes in a Is-A hierarchy:</p><table class="codes"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td></tr><tr><td style="white-space:nowrap">AMB<a name="v3-EntityHandling-AMB"> </a></td><td>Ambient Temperature</td><td>Keep at ambient temperature, 22 +/- 2C</td></tr><tr><td style="white-space:nowrap">C37<a name="v3-EntityHandling-C37"> </a></td><td>Body Temperature</td><td>Critical to keep at body temperature 36-38C</td></tr><tr><td style="white-space:nowrap">CAMB<a name="v3-EntityHandling-CAMB"> </a></td><td>Critical Ambient temperature</td><td>Critical ambient - must not be refrigerated or frozen.</td></tr><tr><td style="white-space:nowrap">CATM<a name="v3-EntityHandling-CATM"> </a></td><td>Protect from Air</td><td>Critical. Do not expose to atmosphere.  Do not uncap.</td></tr><tr><td style="white-space:nowrap">CFRZ<a name="v3-EntityHandling-CFRZ"> </a></td><td>Critical frozen</td><td>Critical frozen. Specimen must not be allowed to thaw until immediately prior to testing.</td></tr><tr><td style="white-space:nowrap">CREF<a name="v3-EntityHandling-CREF"> </a></td><td>Critical refrigerated temperature</td><td>Critical refrigerated - must not be allowed to freeze or warm until imediately prior to testing.</td></tr><tr><td style="white-space:nowrap">DFRZ<a name="v3-EntityHandling-DFRZ"> </a></td><td>Deep Frozen</td><td>Deep Frozen -16 to -20C.</td></tr><tr><td style="white-space:nowrap">DRY<a name="v3-EntityHandling-DRY"> </a></td><td>dry</td><td>Keep in a dry environment</td></tr><tr><td style="white-space:nowrap">FRZ<a name="v3-EntityHandling-FRZ"> </a></td><td>frozen</td><td>Keep frozen below 0 ?C</td></tr><tr><td style="white-space:nowrap">MTLF<a name="v3-EntityHandling-MTLF"> </a></td><td>Metal Free</td><td>Container is free of heavy metals, including lead.</td></tr><tr><td style="white-space:nowrap">NTR<a name="v3-EntityHandling-NTR"> </a></td><td>nitrogen</td><td>Keep in liquid nitrogen</td></tr><tr><td style="white-space:nowrap">PRTL<a name="v3-EntityHandling-PRTL"> </a></td><td>Protect from Light</td><td>Protect from light (eg. Wrap in aluminum foil).</td></tr><tr><td style="white-space:nowrap">PSA<a name="v3-EntityHandling-PSA"> </a></td><td>do not shake</td><td>Do not shake</td></tr><tr><td style="white-space:nowrap">PSO<a name="v3-EntityHandling-PSO"> </a></td><td>no shock</td><td>Protect against shock</td></tr><tr><td style="white-space:nowrap">REF<a name="v3-EntityHandling-REF"> </a></td><td>Refrigerated temperature</td><td>Keep at refrigerated temperature:4-8C Accidental warming or freezing is of little consequence.</td></tr><tr><td style="white-space:nowrap">SBU<a name="v3-EntityHandling-SBU"> </a></td><td>Shake before use</td><td>Shake thoroughly before using</td></tr><tr><td style="white-space:nowrap">UFRZ<a name="v3-EntityHandling-UFRZ"> </a></td><td>Ultra frozen</td><td>Ultra cold frozen -75 to -85C.  Ultra cold freezer is typically at temperature of dry ice.</td></tr><tr><td style="white-space:nowrap">UPR<a name="v3-EntityHandling-UPR"> </a></td><td>upright</td><td>Keep upright, do not turn upside down</td></tr></table></div>
  </text>
  <extension
             url="http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status">
    <valueCode value="external"/>
  </extension>
  <extension
             url="http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm">
    <valueInteger value="0"/>
  </extension>
  <extension url="http://hl7.org/fhir/StructureDefinition/package-source">
    <extension url="packageId">
      <valueId value="hl7.fhir.uv.xver-r4.r4b"/>
    </extension>
    <extension url="version">
      <valueString value="0.0.1-snapshot-2"/>
    </extension>
  </extension>
  <extension
             url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
    <valueCode value="fhir"/>
  </extension>
  <url value="http://terminology.hl7.org/CodeSystem/v3-EntityHandling"/>
  <version value="2018-08-12"/>
  <name value="v3.EntityHandling"/>
  <title value="v3 Code System EntityHandling"/>
  <status value="active"/>
  <experimental value="false"/>
  <date value="2018-08-12T00:00:00+10:00"/>
  <publisher value="FHIR Infrastructure"/>
  <contact>
    <name value="FHIR Infrastructure"/>
    <telecom>
      <system value="url"/>
      <value value="http://www.hl7.org/Special/committees/fiwg"/>
    </telecom>
  </contact>
  <description value="**** MISSING DEFINITIONS ****"/>
  <jurisdiction>
    <coding>
      <system value="http://unstats.un.org/unsd/methods/m49/m49.htm"/>
      <code value="001"/>
      <display value="World"/>
    </coding>
  </jurisdiction>
  <caseSensitive value="true"/>
  <valueSet
            value="http://terminology.hl7.org/ValueSet/v3-EntityHandling|3.0.0"/>
  <hierarchyMeaning value="is-a"/>
  <content value="complete"/>
  <concept>
    <code value="AMB"/>
    <display value="Ambient Temperature"/>
    <definition value="Keep at ambient temperature, 22 +/- 2C"/>
  </concept>
  <concept>
    <code value="C37"/>
    <display value="Body Temperature"/>
    <definition value="Critical to keep at body temperature 36-38C"/>
  </concept>
  <concept>
    <code value="CAMB"/>
    <display value="Critical Ambient temperature"/>
    <definition
                value="Critical ambient - must not be refrigerated or frozen."/>
  </concept>
  <concept>
    <code value="CATM"/>
    <display value="Protect from Air"/>
    <definition
                value="Critical. Do not expose to atmosphere.  Do not uncap."/>
  </concept>
  <concept>
    <code value="CFRZ"/>
    <display value="Critical frozen"/>
    <definition
                value="Critical frozen. Specimen must not be allowed to thaw until immediately prior to testing."/>
  </concept>
  <concept>
    <code value="CREF"/>
    <display value="Critical refrigerated temperature"/>
    <definition
                value="Critical refrigerated - must not be allowed to freeze or warm until imediately prior to testing."/>
  </concept>
  <concept>
    <code value="DFRZ"/>
    <display value="Deep Frozen"/>
    <definition value="Deep Frozen -16 to -20C."/>
  </concept>
  <concept>
    <code value="DRY"/>
    <display value="dry"/>
    <definition value="Keep in a dry environment"/>
  </concept>
  <concept>
    <code value="FRZ"/>
    <display value="frozen"/>
    <definition value="Keep frozen below 0 ?C"/>
  </concept>
  <concept>
    <code value="MTLF"/>
    <display value="Metal Free"/>
    <definition value="Container is free of heavy metals, including lead."/>
  </concept>
  <concept>
    <code value="NTR"/>
    <display value="nitrogen"/>
    <definition value="Keep in liquid nitrogen"/>
  </concept>
  <concept>
    <code value="PRTL"/>
    <display value="Protect from Light"/>
    <definition value="Protect from light (eg. Wrap in aluminum foil)."/>
  </concept>
  <concept>
    <code value="PSA"/>
    <display value="do not shake"/>
    <definition value="Do not shake"/>
  </concept>
  <concept>
    <code value="PSO"/>
    <display value="no shock"/>
    <definition value="Protect against shock"/>
  </concept>
  <concept>
    <code value="REF"/>
    <display value="Refrigerated temperature"/>
    <definition
                value="Keep at refrigerated temperature:4-8C Accidental warming or freezing is of little consequence."/>
  </concept>
  <concept>
    <code value="SBU"/>
    <display value="Shake before use"/>
    <definition value="Shake thoroughly before using"/>
  </concept>
  <concept>
    <code value="UFRZ"/>
    <display value="Ultra frozen"/>
    <definition
                value="Ultra cold frozen -75 to -85C.  Ultra cold freezer is typically at temperature of dry ice."/>
  </concept>
  <concept>
    <code value="UPR"/>
    <display value="upright"/>
    <definition value="Keep upright, do not turn upside down"/>
  </concept>
</CodeSystem>