Extensions for Using Data Elements from FHIR STU3 in FHIR R4B - Downloaded Version null See the Directory of published versions
The FHIR STU3 resource is represented in FHIR R4B via the ImagingStudy resource.
Note that there is a profile defined to simplify use of this cross-version resource representation:Profile: ImagingStudy
A computable version of the following element information is available in: R3ImagingStudyElementMapToR4B
| Source Element (FHIR STU3) | Target(s) | Comments |
|---|---|---|
ImagingStudy |
||
ImagingStudy.meta |
ImagingStudy.meta Extension: ExtensionImagingStudy_Meta |
Element ImagingStudy.meta is mapped to FHIR R4B element ImagingStudy.meta as SourceIsBroaderThanTarget.The mappings for ImagingStudy.meta do not cover the following types: Meta.The mappings for ImagingStudy.meta do not cover the following types based on type expansion: lastUpdated, profile, security, tag, versionId. |
ImagingStudy.implicitRules |
ImagingStudy.implicitRules | Element ImagingStudy.implicitRules is mapped to FHIR R4B element ImagingStudy.implicitRules as Equivalent. |
ImagingStudy.language |
ImagingStudy.language | Element ImagingStudy.language is mapped to FHIR R4B element ImagingStudy.language as Equivalent. |
ImagingStudy.text |
ImagingStudy.text Extension: ExtensionImagingStudy_Text |
Element ImagingStudy.text is mapped to FHIR R4B element ImagingStudy.text as SourceIsBroaderThanTarget.The mappings for ImagingStudy.text do not cover the following types: Narrative.The mappings for ImagingStudy.text do not cover the following types based on type expansion: div, status. |
ImagingStudy.contained |
ImagingStudy.contained | Element ImagingStudy.contained is mapped to FHIR R4B element ImagingStudy.contained as SourceIsBroaderThanTarget. |
ImagingStudy.uid |
ImagingStudy.identifier Extension: ExtensionImagingStudy_Uid |
Element ImagingStudy.uid is mapped to FHIR R4B element ImagingStudy.identifier as RelatedTo.The mappings for ImagingStudy.uid do not cover the following types: oid.The mappings for ImagingStudy.uid do not cover the following types based on type expansion: value. |
ImagingStudy.accession |
ImagingStudy.identifier Extension: ExtensionImagingStudy_Accession |
Element ImagingStudy.accession is mapped to FHIR R4B element ImagingStudy.identifier as RelatedTo.The mappings for ImagingStudy.accession do not cover the following types: Identifier.The mappings for ImagingStudy.accession do not cover the following types based on type expansion: assigner, period, system, type, use, value. |
ImagingStudy.identifier |
ImagingStudy.identifier Extension: ExtensionImagingStudy_Identifier |
Element ImagingStudy.identifier is mapped to FHIR R4B element ImagingStudy.identifier as SourceIsBroaderThanTarget.The mappings for ImagingStudy.identifier do not cover the following types: Identifier.The mappings for ImagingStudy.identifier do not cover the following types based on type expansion: assigner, period, system, type, use, value. |
ImagingStudy.availability |
Extension: ExtensionImagingStudy_Availability | Element ImagingStudy.availability has a context of ImagingStudy based on following the parent source element upwards and mapping to ImagingStudy.Element ImagingStudy.availability has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element). |
ImagingStudy.modalityList |
ImagingStudy.modality | Element ImagingStudy.modalityList is mapped to FHIR R4B element ImagingStudy.modality as Equivalent. |
ImagingStudy.patient |
ImagingStudy.subject Standard Extension: alternate-reference |
Element ImagingStudy.patient is mapped to FHIR R4B element ImagingStudy.subject as SourceIsBroaderThanTarget.The mappings for ImagingStudy.patient do not cover the following types based on type expansion: display, identifier, reference.The standard extension alternate-reference has been mapped as the representation of FHIR STU3 element ImagingStudy.patient with unmapped reference targets: Patient. |
ImagingStudy.context |
ImagingStudy.encounter Standard Extension: alternate-reference |
Element ImagingStudy.context is mapped to FHIR R4B element ImagingStudy.encounter as SourceIsBroaderThanTarget.The mappings for ImagingStudy.context do not cover the following types based on type expansion: display, identifier, reference.The standard extension alternate-reference has been mapped as the representation of FHIR STU3 element ImagingStudy.context with unmapped reference targets: Encounter, EpisodeOfCare. |
ImagingStudy.started |
ImagingStudy.started | Element ImagingStudy.started is mapped to FHIR R4B element ImagingStudy.started as Equivalent. |
ImagingStudy.basedOn |
ImagingStudy.basedOn Standard Extension: alternate-reference |
Element ImagingStudy.basedOn is mapped to FHIR R4B element ImagingStudy.basedOn as RelatedTo.The standard extension alternate-reference has been mapped as the representation of FHIR STU3 element ImagingStudy.basedOn with unmapped reference targets: CarePlan, ProcedureRequest, ReferralRequest. |
ImagingStudy.referrer |
ImagingStudy.referrer Standard Extension: alternate-reference |
Element ImagingStudy.referrer is mapped to FHIR R4B element ImagingStudy.referrer as SourceIsBroaderThanTarget.The mappings for ImagingStudy.referrer do not cover the following types based on type expansion: display, identifier, reference.The standard extension alternate-reference has been mapped as the representation of FHIR STU3 element ImagingStudy.referrer with unmapped reference targets: Practitioner. |
ImagingStudy.interpreter |
ImagingStudy.interpreter Standard Extension: alternate-reference |
Element ImagingStudy.interpreter is mapped to FHIR R4B element ImagingStudy.interpreter as SourceIsBroaderThanTarget.The mappings for ImagingStudy.interpreter do not cover the following types based on type expansion: display, identifier, reference.The standard extension alternate-reference has been mapped as the representation of FHIR STU3 element ImagingStudy.interpreter with unmapped reference targets: Practitioner. |
ImagingStudy.endpoint |
ImagingStudy.endpoint Standard Extension: alternate-reference |
Element ImagingStudy.endpoint is mapped to FHIR R4B element ImagingStudy.endpoint as SourceIsBroaderThanTarget.The mappings for ImagingStudy.endpoint do not cover the following types based on type expansion: display, identifier, reference.The standard extension alternate-reference has been mapped as the representation of FHIR STU3 element ImagingStudy.endpoint with unmapped reference targets: Endpoint. |
ImagingStudy.numberOfSeries |
ImagingStudy.numberOfSeries | Element ImagingStudy.numberOfSeries is mapped to FHIR R4B element ImagingStudy.numberOfSeries as Equivalent. |
ImagingStudy.numberOfInstances |
ImagingStudy.numberOfInstances | Element ImagingStudy.numberOfInstances is mapped to FHIR R4B element ImagingStudy.numberOfInstances as Equivalent. |
ImagingStudy.procedureReference |
ImagingStudy.procedureReference Standard Extension: alternate-reference |
Element ImagingStudy.procedureReference is mapped to FHIR R4B element ImagingStudy.procedureReference as SourceIsBroaderThanTarget.The mappings for ImagingStudy.procedureReference do not cover the following types based on type expansion: display, identifier, reference.The standard extension alternate-reference has been mapped as the representation of FHIR STU3 element ImagingStudy.procedureReference with unmapped reference targets: Procedure. |
ImagingStudy.procedureCode |
ImagingStudy.procedureCode | Element ImagingStudy.procedureCode is mapped to FHIR R4B element ImagingStudy.procedureCode as Equivalent. |
ImagingStudy.reason |
ImagingStudy.reasonCode | Element ImagingStudy.reason is mapped to FHIR R4B element ImagingStudy.reasonCode as SourceIsNarrowerThanTarget. |
ImagingStudy.description |
ImagingStudy.description | Element ImagingStudy.description is mapped to FHIR R4B element ImagingStudy.description as Equivalent. |
ImagingStudy.series |
ImagingStudy.series | Element ImagingStudy.series is mapped to FHIR R4B element ImagingStudy.series as Equivalent. |
ImagingStudy.series.uid |
ImagingStudy.series.uid | Element ImagingStudy.series.uid is mapped to FHIR R4B element ImagingStudy.series.uid as SourceIsNarrowerThanTarget. |
ImagingStudy.series.number |
ImagingStudy.series.number | Element ImagingStudy.series.number is mapped to FHIR R4B element ImagingStudy.series.number as Equivalent. |
ImagingStudy.series.modality |
ImagingStudy.series.modality | Element ImagingStudy.series.modality is mapped to FHIR R4B element ImagingStudy.series.modality as Equivalent. |
ImagingStudy.series.description |
ImagingStudy.series.description | Element ImagingStudy.series.description is mapped to FHIR R4B element ImagingStudy.series.description as Equivalent. |
ImagingStudy.series.numberOfInstances |
ImagingStudy.series.numberOfInstances | Element ImagingStudy.series.numberOfInstances is mapped to FHIR R4B element ImagingStudy.series.numberOfInstances as Equivalent. |
ImagingStudy.series.availability |
Extension: ExtensionImagingStudy_Series_Availability | Element ImagingStudy.series.availability has a context of ImagingStudy.series based on following the parent source element upwards and mapping to ImagingStudy.Element ImagingStudy.series.availability has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element). |
ImagingStudy.series.endpoint |
ImagingStudy.series.endpoint Standard Extension: alternate-reference |
Element ImagingStudy.series.endpoint is mapped to FHIR R4B element ImagingStudy.series.endpoint as SourceIsBroaderThanTarget.The mappings for ImagingStudy.series.endpoint do not cover the following types based on type expansion: display, identifier, reference.The standard extension alternate-reference has been mapped as the representation of FHIR STU3 element ImagingStudy.series.endpoint with unmapped reference targets: Endpoint. |
ImagingStudy.series.bodySite |
ImagingStudy.series.bodySite | Element ImagingStudy.series.bodySite is mapped to FHIR R4B element ImagingStudy.series.bodySite as Equivalent. |
ImagingStudy.series.laterality |
ImagingStudy.series.laterality | Element ImagingStudy.series.laterality is mapped to FHIR R4B element ImagingStudy.series.laterality as Equivalent. |
ImagingStudy.series.started |
ImagingStudy.series.started | Element ImagingStudy.series.started is mapped to FHIR R4B element ImagingStudy.series.started as Equivalent. |
ImagingStudy.series.performer |
ImagingStudy.series.performer | Element ImagingStudy.series.performer is mapped to FHIR R4B element ImagingStudy.series.performer as Equivalent. |
ImagingStudy.series.instance |
ImagingStudy.series.instance | Element ImagingStudy.series.instance is mapped to FHIR R4B element ImagingStudy.series.instance as Equivalent. |
ImagingStudy.series.instance.uid |
ImagingStudy.series.instance.uid | Element ImagingStudy.series.instance.uid is mapped to FHIR R4B element ImagingStudy.series.instance.uid as SourceIsNarrowerThanTarget. |
ImagingStudy.series.instance.number |
ImagingStudy.series.instance.number | Element ImagingStudy.series.instance.number is mapped to FHIR R4B element ImagingStudy.series.instance.number as Equivalent. |
ImagingStudy.series.instance.sopClass |
ImagingStudy.series.instance.sopClass Extension: ExtensionImagingStudy_Series_Instance_SopClass |
Element ImagingStudy.series.instance.sopClass is mapped to FHIR R4B element ImagingStudy.series.instance.sopClass as SourceIsBroaderThanTarget.The mappings for ImagingStudy.series.instance.sopClass do not cover the following types: oid.The mappings for ImagingStudy.series.instance.sopClass do not cover the following types based on type expansion: value. |
ImagingStudy.series.instance.title |
ImagingStudy.series.instance.title | Element ImagingStudy.series.instance.title is mapped to FHIR R4B element ImagingStudy.series.instance.title as Equivalent. |