Extensions for Using Data Elements from FHIR STU3 in FHIR R4B
0.1.0 - STU International flag

Extensions for Using Data Elements from FHIR STU3 in FHIR R4B - Downloaded Version null See the Directory of published versions

Lookup for Profile_R3_DeviceUseStatement_R4B

Lookup for FHIR STU3 DeviceUseStatement for use in FHIR R4B

The FHIR STU3 resource is represented in FHIR R4B via the DeviceUseStatement resource.

Note that there is a profile defined to simplify use of this cross-version resource representation:Profile: DeviceUseStatement

A computable version of the following element information is available in: R3DeviceUseStatementElementMapToR4B

Source Element (FHIR STU3) Target(s) Comments
DeviceUseStatement    
DeviceUseStatement.meta DeviceUseStatement.meta
Extension: ExtensionDeviceUseStatement_Meta
Element DeviceUseStatement.meta is mapped to FHIR R4B element DeviceUseStatement.meta as SourceIsBroaderThanTarget.
The mappings for DeviceUseStatement.meta do not cover the following types: Meta.
The mappings for DeviceUseStatement.meta do not cover the following types based on type expansion: lastUpdated, profile, security, tag, versionId.
DeviceUseStatement.implicitRules DeviceUseStatement.implicitRules Element DeviceUseStatement.implicitRules is mapped to FHIR R4B element DeviceUseStatement.implicitRules as Equivalent.
DeviceUseStatement.language DeviceUseStatement.language Element DeviceUseStatement.language is mapped to FHIR R4B element DeviceUseStatement.language as Equivalent.
DeviceUseStatement.text DeviceUseStatement.text
Extension: ExtensionDeviceUseStatement_Text
Element DeviceUseStatement.text is mapped to FHIR R4B element DeviceUseStatement.text as SourceIsBroaderThanTarget.
The mappings for DeviceUseStatement.text do not cover the following types: Narrative.
The mappings for DeviceUseStatement.text do not cover the following types based on type expansion: div, status.
DeviceUseStatement.contained DeviceUseStatement.contained Element DeviceUseStatement.contained is mapped to FHIR R4B element DeviceUseStatement.contained as SourceIsBroaderThanTarget.
DeviceUseStatement.identifier DeviceUseStatement.identifier
Extension: ExtensionDeviceUseStatement_Identifier
Element DeviceUseStatement.identifier is mapped to FHIR R4B element DeviceUseStatement.identifier as SourceIsBroaderThanTarget.
The mappings for DeviceUseStatement.identifier do not cover the following types: Identifier.
The mappings for DeviceUseStatement.identifier do not cover the following types based on type expansion: assigner, period, system, type, use, value.
DeviceUseStatement.status DeviceUseStatement.status Element DeviceUseStatement.status is mapped to FHIR R4B element DeviceUseStatement.status as Equivalent.
DeviceUseStatement.subject DeviceUseStatement.subject
Standard Extension: alternate-reference
Element DeviceUseStatement.subject is mapped to FHIR R4B element DeviceUseStatement.subject as SourceIsBroaderThanTarget.
The mappings for DeviceUseStatement.subject do not cover the following types based on type expansion: display, identifier, reference.
The standard extension alternate-reference has been mapped as the representation of FHIR STU3 element DeviceUseStatement.subject with unmapped reference targets: Group, Patient.
DeviceUseStatement.whenUsed Extension: ExtensionDeviceUseStatement_WhenUsed Element DeviceUseStatement.whenUsed has a context of DeviceUseStatement based on following the parent source element upwards and mapping to DeviceUseStatement.
Element DeviceUseStatement.whenUsed has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element).
DeviceUseStatement.timing[x] DeviceUseStatement.timing[x]
Extension: ExtensionDeviceUseStatement_Timing
Element DeviceUseStatement.timing[x] is mapped to FHIR R4B element DeviceUseStatement.timing[x] as SourceIsBroaderThanTarget.
The mappings for DeviceUseStatement.timing[x] do not cover the following types: Period, Timing.
The target context DeviceUseStatement.timing[x] is a choice-type element and cannot directly hold extensions. The context is moved up to parent element DeviceUseStatement.
DeviceUseStatement.recordedOn DeviceUseStatement.recordedOn Element DeviceUseStatement.recordedOn is mapped to FHIR R4B element DeviceUseStatement.recordedOn as Equivalent.
DeviceUseStatement.source DeviceUseStatement.source
Standard Extension: alternate-reference
Element DeviceUseStatement.source is mapped to FHIR R4B element DeviceUseStatement.source as SourceIsBroaderThanTarget.
The standard extension alternate-reference has been mapped as the representation of FHIR STU3 element DeviceUseStatement.source with unmapped reference targets: Patient, Practitioner, RelatedPerson.
DeviceUseStatement.device DeviceUseStatement.device
Standard Extension: alternate-reference
Element DeviceUseStatement.device is mapped to FHIR R4B element DeviceUseStatement.device as SourceIsBroaderThanTarget.
The mappings for DeviceUseStatement.device do not cover the following types based on type expansion: display, identifier, reference.
The standard extension alternate-reference has been mapped as the representation of FHIR STU3 element DeviceUseStatement.device with unmapped reference targets: Device.
DeviceUseStatement.indication DeviceUseStatement.reasonCode Element DeviceUseStatement.indication is mapped to FHIR R4B element DeviceUseStatement.reasonCode as Equivalent.
DeviceUseStatement.bodySite DeviceUseStatement.bodySite Element DeviceUseStatement.bodySite is mapped to FHIR R4B element DeviceUseStatement.bodySite as Equivalent.
DeviceUseStatement.note DeviceUseStatement.note
Extension: ExtensionDeviceUseStatement_Note
Element DeviceUseStatement.note is mapped to FHIR R4B element DeviceUseStatement.note as SourceIsBroaderThanTarget.
The mappings for DeviceUseStatement.note do not cover the following types: Annotation.
The mappings for DeviceUseStatement.note do not cover the following types based on type expansion: author[x], text, time.