Extensions for Using Data Elements from FHIR STU3 in FHIR R4B - Downloaded Version null See the Directory of published versions
The FHIR STU3 resource is represented in FHIR R4B via the ClinicalImpression resource.
Note that there is a profile defined to simplify use of this cross-version resource representation:Profile: ClinicalImpression
A computable version of the following element information is available in: R3ClinicalImpressionElementMapToR4B
| Source Element (FHIR STU3) | Target(s) | Comments |
|---|---|---|
ClinicalImpression |
||
ClinicalImpression.meta |
ClinicalImpression.meta Extension: ExtensionClinicalImpression_Meta |
Element ClinicalImpression.meta is mapped to FHIR R4B element ClinicalImpression.meta as SourceIsBroaderThanTarget.The mappings for ClinicalImpression.meta do not cover the following types: Meta.The mappings for ClinicalImpression.meta do not cover the following types based on type expansion: lastUpdated, profile, security, tag, versionId. |
ClinicalImpression.implicitRules |
ClinicalImpression.implicitRules | Element ClinicalImpression.implicitRules is mapped to FHIR R4B element ClinicalImpression.implicitRules as Equivalent. |
ClinicalImpression.language |
ClinicalImpression.language | Element ClinicalImpression.language is mapped to FHIR R4B element ClinicalImpression.language as Equivalent. |
ClinicalImpression.text |
ClinicalImpression.text Extension: ExtensionClinicalImpression_Text |
Element ClinicalImpression.text is mapped to FHIR R4B element ClinicalImpression.text as SourceIsBroaderThanTarget.The mappings for ClinicalImpression.text do not cover the following types: Narrative.The mappings for ClinicalImpression.text do not cover the following types based on type expansion: div, status. |
ClinicalImpression.contained |
ClinicalImpression.contained | Element ClinicalImpression.contained is mapped to FHIR R4B element ClinicalImpression.contained as SourceIsBroaderThanTarget. |
ClinicalImpression.identifier |
ClinicalImpression.identifier Extension: ExtensionClinicalImpression_Identifier |
Element ClinicalImpression.identifier is mapped to FHIR R4B element ClinicalImpression.identifier as SourceIsBroaderThanTarget.The mappings for ClinicalImpression.identifier do not cover the following types: Identifier.The mappings for ClinicalImpression.identifier do not cover the following types based on type expansion: assigner, period, system, type, use, value. |
ClinicalImpression.status |
ClinicalImpression.status | Element ClinicalImpression.status is mapped to FHIR R4B element ClinicalImpression.status as Equivalent. |
ClinicalImpression.code |
ClinicalImpression.code | Element ClinicalImpression.code is mapped to FHIR R4B element ClinicalImpression.code as Equivalent. |
ClinicalImpression.description |
ClinicalImpression.description | Element ClinicalImpression.description is mapped to FHIR R4B element ClinicalImpression.description as Equivalent. |
ClinicalImpression.subject |
ClinicalImpression.subject Standard Extension: alternate-reference |
Element ClinicalImpression.subject is mapped to FHIR R4B element ClinicalImpression.subject as SourceIsBroaderThanTarget.The mappings for ClinicalImpression.subject do not cover the following types based on type expansion: display, identifier, reference.The standard extension alternate-reference has been mapped as the representation of FHIR STU3 element ClinicalImpression.subject with unmapped reference targets: Group, Patient. |
ClinicalImpression.context |
ClinicalImpression.encounter Standard Extension: alternate-reference |
Element ClinicalImpression.context is mapped to FHIR R4B element ClinicalImpression.encounter as SourceIsBroaderThanTarget.The mappings for ClinicalImpression.context do not cover the following types based on type expansion: display, identifier, reference.The standard extension alternate-reference has been mapped as the representation of FHIR STU3 element ClinicalImpression.context with unmapped reference targets: Encounter, EpisodeOfCare. |
ClinicalImpression.effective[x] |
ClinicalImpression.effective[x] | Element ClinicalImpression.effective[x] is mapped to FHIR R4B element ClinicalImpression.effective[x] as SourceIsBroaderThanTarget.The target context ClinicalImpression.effective[x] is a choice-type element and cannot directly hold extensions. The context is moved up to parent element ClinicalImpression. |
ClinicalImpression.date |
ClinicalImpression.date | Element ClinicalImpression.date is mapped to FHIR R4B element ClinicalImpression.date as Equivalent. |
ClinicalImpression.assessor |
ClinicalImpression.assessor Standard Extension: alternate-reference |
Element ClinicalImpression.assessor is mapped to FHIR R4B element ClinicalImpression.assessor as SourceIsBroaderThanTarget.The mappings for ClinicalImpression.assessor do not cover the following types based on type expansion: display, identifier, reference.The standard extension alternate-reference has been mapped as the representation of FHIR STU3 element ClinicalImpression.assessor with unmapped reference targets: Practitioner. |
ClinicalImpression.previous |
ClinicalImpression.previous Standard Extension: alternate-reference |
Element ClinicalImpression.previous is mapped to FHIR R4B element ClinicalImpression.previous as SourceIsBroaderThanTarget.The mappings for ClinicalImpression.previous do not cover the following types based on type expansion: display, identifier, reference.The standard extension alternate-reference has been mapped as the representation of FHIR STU3 element ClinicalImpression.previous with unmapped reference targets: ClinicalImpression. |
ClinicalImpression.problem |
ClinicalImpression.problem Standard Extension: alternate-reference |
Element ClinicalImpression.problem is mapped to FHIR R4B element ClinicalImpression.problem as SourceIsBroaderThanTarget.The mappings for ClinicalImpression.problem do not cover the following types based on type expansion: display, identifier, reference.The standard extension alternate-reference has been mapped as the representation of FHIR STU3 element ClinicalImpression.problem with unmapped reference targets: AllergyIntolerance, Condition. |
ClinicalImpression.investigation |
ClinicalImpression.investigation | Element ClinicalImpression.investigation is mapped to FHIR R4B element ClinicalImpression.investigation as Equivalent. |
ClinicalImpression.investigation.code |
ClinicalImpression.investigation.code | Element ClinicalImpression.investigation.code is mapped to FHIR R4B element ClinicalImpression.investigation.code as Equivalent. |
ClinicalImpression.investigation.item |
ClinicalImpression.investigation.item Standard Extension: alternate-reference |
Element ClinicalImpression.investigation.item is mapped to FHIR R4B element ClinicalImpression.investigation.item as SourceIsBroaderThanTarget.The standard extension alternate-reference has been mapped as the representation of FHIR STU3 element ClinicalImpression.investigation.item with unmapped reference targets: DiagnosticReport, FamilyMemberHistory, ImagingStudy, Observation, QuestionnaireResponse, RiskAssessment. |
ClinicalImpression.protocol |
ClinicalImpression.protocol | Element ClinicalImpression.protocol is mapped to FHIR R4B element ClinicalImpression.protocol as Equivalent. |
ClinicalImpression.summary |
ClinicalImpression.summary | Element ClinicalImpression.summary is mapped to FHIR R4B element ClinicalImpression.summary as Equivalent. |
ClinicalImpression.finding |
ClinicalImpression.finding | Element ClinicalImpression.finding is mapped to FHIR R4B element ClinicalImpression.finding as Equivalent. |
ClinicalImpression.finding.item[x] |
ClinicalImpression.finding.itemCodeableConcept ClinicalImpression.finding.itemReference Standard Extension: alternate-reference |
Element ClinicalImpression.finding.item[x] is mapped to FHIR R4B element ClinicalImpression.finding.itemCodeableConcept as SourceIsBroaderThanTarget.Element ClinicalImpression.finding.item[x] is mapped to FHIR R4B element ClinicalImpression.finding.itemReference as SourceIsBroaderThanTarget.The standard extension alternate-reference has been mapped as the representation of FHIR STU3 element ClinicalImpression.finding.item[x] with unmapped reference targets: Condition, Observation. |
ClinicalImpression.finding.basis |
ClinicalImpression.finding.basis | Element ClinicalImpression.finding.basis is mapped to FHIR R4B element ClinicalImpression.finding.basis as Equivalent. |
ClinicalImpression.prognosisCodeableConcept |
ClinicalImpression.prognosisCodeableConcept | Element ClinicalImpression.prognosisCodeableConcept is mapped to FHIR R4B element ClinicalImpression.prognosisCodeableConcept as Equivalent. |
ClinicalImpression.prognosisReference |
ClinicalImpression.prognosisReference Standard Extension: alternate-reference |
Element ClinicalImpression.prognosisReference is mapped to FHIR R4B element ClinicalImpression.prognosisReference as SourceIsBroaderThanTarget.The mappings for ClinicalImpression.prognosisReference do not cover the following types based on type expansion: display, identifier, reference.The standard extension alternate-reference has been mapped as the representation of FHIR STU3 element ClinicalImpression.prognosisReference with unmapped reference targets: RiskAssessment. |
ClinicalImpression.action |
Extension: ExtensionClinicalImpression_Action | Element ClinicalImpression.action has a context of ClinicalImpression based on following the parent source element upwards and mapping to ClinicalImpression.Element ClinicalImpression.action has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element). |
ClinicalImpression.note |
ClinicalImpression.note Extension: ExtensionClinicalImpression_Note |
Element ClinicalImpression.note is mapped to FHIR R4B element ClinicalImpression.note as SourceIsBroaderThanTarget.The mappings for ClinicalImpression.note do not cover the following types: Annotation.The mappings for ClinicalImpression.note do not cover the following types based on type expansion: author[x], text, time. |