Extensions for Using Data Elements from FHIR DSTU2 in FHIR R5
0.1.0 - STU International flag

Extensions for Using Data Elements from FHIR DSTU2 in FHIR R5 - Downloaded Version null See the Directory of published versions

Extension: ExtensionDeviceComponent_MeasurementPrinciple

Official URL: http://hl7.org/fhir/1.0/StructureDefinition/extension-DeviceComponent.measurementPrinciple Version: 0.1.0
Standards status: Trial-use Maturity Level: 0 Computable Name: ExtensionDeviceComponent_MeasurementPrinciple

DSTU2: DeviceComponent.measurementPrinciple (new:code)

This extension is part of the cross-version definitions generated to enable use of the element DeviceComponent.measurementPrinciple as defined in FHIR DSTU2 in FHIR R5.

The source element is defined as: DeviceComponent.measurementPrinciple 0..1 code

Across FHIR versions, the element set has been mapped as:

  • DSTU2 DeviceComponent.measurementPrinciple 0..1 code

Following are the generation technical comments: Element DeviceComponent.measurementPrinciple is not mapped to FHIR R5, since FHIR DSTU2 DeviceComponent is not mapped. Element DeviceComponent.measurementPrinciple has no mapping targets in FHIR R5. Typically, this is because the element has been added (is a new element).

Context of Use

    This extension may be used on the following element(s)

    This extension is allowed for use with FHIR versions R5 to R5 .

Usage info

Usages:

You can also check for usages in the FHIR IG Statistics

Formal Views of Extension Content

Description of Profiles, Differentials, Snapshots, and how the XML and JSON presentations work.

This structure is derived from Extension

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Extension 0..1 Extension(5.0.0) DSTU2: other | chemical | electrical | impedance | nuclear | optical | thermal | biological | mechanical | acoustical | manual+ (new)
... url 1..1 uri "http://hl7.org/fhir/1.0/StructureDefinition/extension-DeviceComponent.measurementPrinciple"
... value[x] 0..1 code other | chemical | electrical | impedance | nuclear | optical | thermal | biological | mechanical | acoustical | manual+
Binding: R2MeasurementPrincipleForR5 (0.1.0) (required): Different measurement principle supported by the device.

doco Documentation for this format
NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Extension 0..1 Extension(5.0.0) DSTU2: other | chemical | electrical | impedance | nuclear | optical | thermal | biological | mechanical | acoustical | manual+ (new)
Constraints: ext-1
... id 0..1 id Unique id for inter-element referencing
... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
Constraints: ext-1
... url 1..1 uri "http://hl7.org/fhir/1.0/StructureDefinition/extension-DeviceComponent.measurementPrinciple"

doco Documentation for this format

This structure is derived from Extension

Summary

Simple Extension with the type code: DSTU2: DeviceComponent.measurementPrinciple (new:code)

Maturity: 0

Differential View

This structure is derived from Extension

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Extension 0..1 Extension(5.0.0) DSTU2: other | chemical | electrical | impedance | nuclear | optical | thermal | biological | mechanical | acoustical | manual+ (new)
... url 1..1 uri "http://hl7.org/fhir/1.0/StructureDefinition/extension-DeviceComponent.measurementPrinciple"
... value[x] 0..1 code other | chemical | electrical | impedance | nuclear | optical | thermal | biological | mechanical | acoustical | manual+
Binding: R2MeasurementPrincipleForR5 (0.1.0) (required): Different measurement principle supported by the device.

doco Documentation for this format

Snapshot View

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Extension 0..1 Extension(5.0.0) DSTU2: other | chemical | electrical | impedance | nuclear | optical | thermal | biological | mechanical | acoustical | manual+ (new)
Constraints: ext-1
... id 0..1 id Unique id for inter-element referencing
... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
Constraints: ext-1
... url 1..1 uri "http://hl7.org/fhir/1.0/StructureDefinition/extension-DeviceComponent.measurementPrinciple"

doco Documentation for this format

This structure is derived from Extension

Summary

Simple Extension with the type code: DSTU2: DeviceComponent.measurementPrinciple (new:code)

Maturity: 0

 

Other representations of profile: CSV, Excel, Schematron

Terminology Bindings

Path Status Usage ValueSet Version Source
Extension.value[x] Base required Cross-version ValueSet DSTU2.Measmnt-Principle for use in FHIR R5 📍0.1.0 This IG

Constraints

Id Grade Path(s) Description Expression
ele-1 error Extension, Extension.extension, Extension.value[x] All FHIR elements must have a @value or children hasValue() or (children().count() > id.count())
ext-1 error Extension, Extension.extension Must have either extensions or value[x], not both extension.exists() != value.exists()