Extensions for Using Data Elements from FHIR DSTU2 in FHIR R5
0.1.0 - STU International flag

Extensions for Using Data Elements from FHIR DSTU2 in FHIR R5 - Downloaded Version null See the Directory of published versions

ConceptMap: R2ImagingObjectSelectionElementMapToR5

Official URL: http://hl7.org/fhir/uv/xver/ConceptMap/R2-ImagingObjectSelection-element-map-to-R5 Version: 0.1.0
Standards status: Trial-use Maturity Level: 0 Computable Name: R2ImagingObjectSelectionElementMapToR5

This ConceptMap represents cross-version mappings for elements from a FHIR DSTU2 ImagingObjectSelection to FHIR R5.

Mapping from http://hl7.org/fhir/1.0 to http://hl7.org/fhir/5.0


Group 1 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingObjectSelection|1.0.2 to Basicversion: 5.0.0)

Source CodeRelationshipTarget CodeComment
ImagingObjectSelection.meta (meta)is equivalent toBasic.metaElement matches Basic element path `Basic.meta` (`Resource.meta`), use that element instead. Element `ImagingObjectSelection.meta` is not mapped to FHIR R5, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.meta` has no mapping targets in FHIR R5. Typically, this is because the element has been added (is a new element).
ImagingObjectSelection.implicitRules (implicitRules)is equivalent toBasic.implicitRulesElement matches Basic element path `Basic.implicitRules` (`Resource.implicitRules`), use that element instead. Element `ImagingObjectSelection.implicitRules` is not mapped to FHIR R5, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.implicitRules` has no mapping targets in FHIR R5. Typically, this is because the element has been added (is a new element). Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element as much as possible.
ImagingObjectSelection.language (language)is equivalent toBasic.languageElement matches Basic element path `Basic.language` (`Resource.language`), use that element instead. Element `ImagingObjectSelection.language` is not mapped to FHIR R5, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.language` has no mapping targets in FHIR R5. Typically, this is because the element has been added (is a new element). Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute).
ImagingObjectSelection.text (text)is equivalent toBasic.textElement matches Basic element path `Basic.text` (`DomainResource.text`), use that element instead. Element `ImagingObjectSelection.text` is not mapped to FHIR R5, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.text` has no mapping targets in FHIR R5. Typically, this is because the element has been added (is a new element). Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative.
ImagingObjectSelection.contained (contained)is equivalent toBasic.containedElement matches Basic element path `Basic.contained` (`DomainResource.contained`), use that element instead. Element `ImagingObjectSelection.contained` is not mapped to FHIR R5, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.contained` has no mapping targets in FHIR R5. Typically, this is because the element has been added (is a new element). This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again.
ImagingObjectSelection.author (author)is equivalent toBasic.authorElement matches Basic element path `Basic.author` (`Basic.author`), use that element instead. Element `ImagingObjectSelection.author` is not mapped to FHIR R5, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.author` has no mapping targets in FHIR R5. Typically, this is because the element has been added (is a new element).

Group 2 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingObjectSelection|1.0.2 to DSTU2: Instance UID (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingObjectSelection.uid (uid)is broader thanExtension (DSTU2: Instance UID (new))Element `ImagingObjectSelection.uid` is not mapped to FHIR R5, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.uid` has no mapping targets in FHIR R5. Typically, this is because the element has been added (is a new element).

Group 3 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingObjectSelection|1.0.2 to DSTU2: Patient of the selected objects (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingObjectSelection.patient (patient)is broader thanExtension (DSTU2: Patient of the selected objects (new))Element `ImagingObjectSelection.patient` is not mapped to FHIR R5, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.patient` has no mapping targets in FHIR R5. Typically, this is because the element has been added (is a new element). SOP instances selected in the ImagingObjectSelection can be from different studies, but must be of the same patient.

Group 4 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingObjectSelection|1.0.2 to DSTU2: Reason for selection (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingObjectSelection.title (title)is broader thanExtension (DSTU2: Reason for selection (new))Element `ImagingObjectSelection.title` is not mapped to FHIR R5, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.title` has no mapping targets in FHIR R5. Typically, this is because the element has been added (is a new element). Coded concept of kind of the ImagingObjectSelection. Value set is defined in the DICOM standard Part 16, CID-7010.

Group 5 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingObjectSelection|1.0.2 to DSTU2: Description text (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingObjectSelection.description (description)is broader thanExtension (DSTU2: Description text (new))Element `ImagingObjectSelection.description` is not mapped to FHIR R5, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.description` has no mapping targets in FHIR R5. Typically, this is because the element has been added (is a new element). Free text narrative description of the ImagingObjectSelection.

Group 6 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingObjectSelection|1.0.2 to DSTU2: Authoring time of the selection (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingObjectSelection.authoringTime (authoringTime)is broader thanExtension (DSTU2: Authoring time of the selection (new))Element `ImagingObjectSelection.authoringTime` is not mapped to FHIR R5, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.authoringTime` has no mapping targets in FHIR R5. Typically, this is because the element has been added (is a new element).

Group 7 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingObjectSelection|1.0.2 to DSTU2: Study identity of the selected instances (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingObjectSelection.study (study)is broader thanExtension (DSTU2: Study identity of the selected instances (new))Element `ImagingObjectSelection.study` is not mapped to FHIR R5, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study` has no mapping targets in FHIR R5. Typically, this is because the element has been added (is a new element). Study component represents the study level identity and locator information of the DICOM SOP instances in the selection. It is the top level identity of the hierachical identification of the instances.
ImagingObjectSelection.study.uid (uid)is broader thanExtension.extension:uid (DSTU2: Study instance UID (new))Element `ImagingObjectSelection.study.uid` is part of an existing definition because parent element `ImagingObjectSelection.study` requires a cross-version extension. Element `ImagingObjectSelection.study.uid` is not mapped to FHIR R5, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study.uid` has no mapping targets in FHIR R5. Typically, this is because the element has been added (is a new element).
ImagingObjectSelection.study.url (url)is broader thanExtension.extension:url (DSTU2: Retrieve study URL (new))Element `ImagingObjectSelection.study.url` is part of an existing definition because parent element `ImagingObjectSelection.study` requires a cross-version extension. Element `ImagingObjectSelection.study.url` is not mapped to FHIR R5, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study.url` has no mapping targets in FHIR R5. Typically, this is because the element has been added (is a new element). Study level locator information is optional. If provided, this is the URL to retrieve the entire study with WADO-RS interaction, though only a subset of these are selected in the selection.
ImagingObjectSelection.study.imagingStudy (imagingStudy)is broader thanExtension.extension:imagingStudy (DSTU2: Reference to ImagingStudy (new))Element `ImagingObjectSelection.study.imagingStudy` is part of an existing definition because parent element `ImagingObjectSelection.study` requires a cross-version extension. Element `ImagingObjectSelection.study.imagingStudy` is not mapped to FHIR R5, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study.imagingStudy` has no mapping targets in FHIR R5. Typically, this is because the element has been added (is a new element).
ImagingObjectSelection.study.series (series)is broader thanExtension.extension:series (DSTU2: Series identity of the selected instances (new))Element `ImagingObjectSelection.study.series` is part of an existing definition because parent element `ImagingObjectSelection.study` requires a cross-version extension. Element `ImagingObjectSelection.study.series` is not mapped to FHIR R5, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study.series` has no mapping targets in FHIR R5. Typically, this is because the element has been added (is a new element). Series component represents the series level identity and locator information of the DICOM SOP instances in the selection.
ImagingObjectSelection.study.series.uid (uid)is broader thanExtension.extension:series.extension:uid (DSTU2: Series instance UID (new))Element `ImagingObjectSelection.study.series.uid` is part of an existing definition because parent element `ImagingObjectSelection.study.series` requires a cross-version extension. Element `ImagingObjectSelection.study.series.uid` is not mapped to FHIR R5, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study.series.uid` has no mapping targets in FHIR R5. Typically, this is because the element has been added (is a new element).
ImagingObjectSelection.study.series.url (url)is broader thanExtension.extension:series.extension:url (DSTU2: Retrieve series URL (new))Element `ImagingObjectSelection.study.series.url` is part of an existing definition because parent element `ImagingObjectSelection.study.series` requires a cross-version extension. Element `ImagingObjectSelection.study.series.url` is not mapped to FHIR R5, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study.series.url` has no mapping targets in FHIR R5. Typically, this is because the element has been added (is a new element). Series level locator information is optional. If provided, this is the URL to retrieve the entire series with WADO-RS interaction, though only a subset of these are selected in the selection.
ImagingObjectSelection.study.series.instance (instance)is broader thanExtension.extension:series.extension:instance (DSTU2: The selected instance (new))Element `ImagingObjectSelection.study.series.instance` is part of an existing definition because parent element `ImagingObjectSelection.study.series` requires a cross-version extension. Element `ImagingObjectSelection.study.series.instance` is not mapped to FHIR R5, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study.series.instance` has no mapping targets in FHIR R5. Typically, this is because the element has been added (is a new element). SOP Instance component identify the instance selected, along with the study and series identities to form the DICOM identity hierachy.
ImagingObjectSelection.study.series.instance.sopClass (sopClass)is broader thanExtension.extension:series.extension:instance.extension:sopClass (DSTU2: SOP class UID of instance (new))Element `ImagingObjectSelection.study.series.instance.sopClass` is part of an existing definition because parent element `ImagingObjectSelection.study.series.instance` requires a cross-version extension. Element `ImagingObjectSelection.study.series.instance.sopClass` is not mapped to FHIR R5, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study.series.instance.sopClass` has no mapping targets in FHIR R5. Typically, this is because the element has been added (is a new element). SOP class UID identifies the type of the selected instances, e.g. CT image, Gray scale softcopy presentation state, ECG waveform, etc.
ImagingObjectSelection.study.series.instance.uid (uid)is broader thanExtension.extension:series.extension:instance.extension:uid (DSTU2: Selected instance UID (new))Element `ImagingObjectSelection.study.series.instance.uid` is part of an existing definition because parent element `ImagingObjectSelection.study.series.instance` requires a cross-version extension. Element `ImagingObjectSelection.study.series.instance.uid` is not mapped to FHIR R5, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study.series.instance.uid` has no mapping targets in FHIR R5. Typically, this is because the element has been added (is a new element). SOP instance UID identifies the instance.
ImagingObjectSelection.study.series.instance.url (url)is broader thanExtension.extension:series.extension:instance.extension:url (DSTU2: Retrieve instance URL (new))Element `ImagingObjectSelection.study.series.instance.url` is part of an existing definition because parent element `ImagingObjectSelection.study.series.instance` requires a cross-version extension. Element `ImagingObjectSelection.study.series.instance.url` is not mapped to FHIR R5, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study.series.instance.url` has no mapping targets in FHIR R5. Typically, this is because the element has been added (is a new element). Instance level locator information is required.
ImagingObjectSelection.study.series.instance.frames (frames)is broader thanExtension.extension:series.extension:instance.extension:frames (DSTU2: The frame set (new))Element `ImagingObjectSelection.study.series.instance.frames` is part of an existing definition because parent element `ImagingObjectSelection.study.series.instance` requires a cross-version extension. Element `ImagingObjectSelection.study.series.instance.frames` is not mapped to FHIR R5, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study.series.instance.frames` has no mapping targets in FHIR R5. Typically, this is because the element has been added (is a new element). This component may be used if the referenced image SOP Instance is a multi-frame image.
ImagingObjectSelection.study.series.instance.frames.frameNumbers (frameNumbers)is broader thanExtension.extension:series.extension:instance.extension:frames.extension:frameNumbers (DSTU2: Frame numbers (new))Element `ImagingObjectSelection.study.series.instance.frames.frameNumbers` is part of an existing definition because parent element `ImagingObjectSelection.study.series.instance.frames` requires a cross-version extension. Element `ImagingObjectSelection.study.series.instance.frames.frameNumbers` is not mapped to FHIR R5, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study.series.instance.frames.frameNumbers` has no mapping targets in FHIR R5. Typically, this is because the element has been added (is a new element).
ImagingObjectSelection.study.series.instance.frames.url (url)is broader thanExtension.extension:series.extension:instance.extension:frames.extension:url (DSTU2: Retrieve frame URL (new))Element `ImagingObjectSelection.study.series.instance.frames.url` is part of an existing definition because parent element `ImagingObjectSelection.study.series.instance.frames` requires a cross-version extension. Element `ImagingObjectSelection.study.series.instance.frames.url` is not mapped to FHIR R5, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study.series.instance.frames.url` has no mapping targets in FHIR R5. Typically, this is because the element has been added (is a new element). Frame level locator information is required.