Extensions for Using Data Elements from FHIR DSTU2 in FHIR R5
0.1.0 - STU International flag

Extensions for Using Data Elements from FHIR DSTU2 in FHIR R5 - Downloaded Version null See the Directory of published versions

: v2-0174 - XML Representation

Page standards status: Trial-use Maturity Level: 0

Raw xml | Download


<CodeSystem xmlns="http://hl7.org/fhir">
  <id value="v2-0174"/>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: CodeSystem v2-0174</b></p><a name="v2-0174"> </a><a name="hcv2-0174"> </a><p><b>Properties</b></p><p><b>This code system defines the following properties for its concepts</b></p><table class="grid"><tr><td><b>Name</b></td><td><b>Code</b></td><td><b>URI</b></td><td><b>Type</b></td></tr><tr><td>Status</td><td>status</td><td>http://hl7.org/fhir/concept-properties#status</td><td>code</td></tr><tr><td>Inactive</td><td>inactive</td><td>http://hl7.org/fhir/concept-properties#inactive</td><td>boolean</td></tr><tr><td>effectiveDate</td><td>effectiveDate</td><td>http://hl7.org/fhir/concept-properties#effectiveDate</td><td>dateTime</td></tr><tr><td>Deprecation Date</td><td>deprecationDate</td><td>http://hl7.org/fhir/concept-properties#deprecationDate</td><td>dateTime</td></tr><tr><td>Retirement Date</td><td>retirementDate</td><td>http://hl7.org/fhir/concept-properties#retirementDate</td><td>dateTime</td></tr><tr><td>Not Selectable</td><td>notSelectable</td><td>http://hl7.org/fhir/concept-properties#notSelectable</td><td>boolean</td></tr><tr><td>Parent</td><td>parent</td><td>http://hl7.org/fhir/concept-properties#parent</td><td>code</td></tr><tr><td>Child</td><td>child</td><td>http://hl7.org/fhir/concept-properties#child</td><td>code</td></tr><tr><td>Part Of</td><td>partOf</td><td>http://hl7.org/fhir/concept-properties#partOf</td><td>code</td></tr><tr><td>Synonym</td><td>synonym</td><td>http://hl7.org/fhir/concept-properties#synonym</td><td>code</td></tr><tr><td>Comment</td><td>comment</td><td>http://hl7.org/fhir/concept-properties#comment</td><td>string</td></tr><tr><td>itemWeight</td><td>itemWeight</td><td>http://hl7.org/fhir/concept-properties#itemWeight</td><td>decimal</td></tr></table><p><b>Concepts</b></p><p>This case-insensitive code system <code>http://hl7.org/fhir/v2/0174</code> defines the following codes:</p><table class="codes"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td></tr><tr><td style="white-space:nowrap">A<a name="v2-0174-A"> </a></td><td>Atomic service/test/observation (test code or treatment code)</td></tr><tr><td style="white-space:nowrap">C<a name="v2-0174-C"> </a></td><td>Single observation calculated via a rule or formula from other independent observations (e.g. Alveolar-arterial ratio, cardiac output)</td></tr><tr><td style="white-space:nowrap">F<a name="v2-0174-F"> </a></td><td>Functional procedure that may consist of one or more interrelated measures (e.g. glucose tolerance test, creatinine clearance), usually done at different times and/or on different specimens</td></tr><tr><td style="white-space:nowrap">P<a name="v2-0174-P"> </a></td><td>Profile or battery consisting of many independent atomic observations (e.g. SMA12, electrolytes), usually done at one instrument on one specimen</td></tr><tr><td style="white-space:nowrap">S<a name="v2-0174-S"> </a></td><td>Superset-a set of batteries or procedures ordered under a single code unit but processed as separate batteries (e.g. routines = CBC, UA, electrolytes)&lt;p&gt;This set indicates that the code being described is used to order multiple service/test/observation b</td></tr></table><p><b>Additional Language Displays</b></p><table class="codes"><tr><td><b>Code</b></td><td><b>Deutsch (German, de)</b></td><td><b>Nederlands (Dutch, nl)</b></td></tr><tr><td>A</td><td>Einzeluntersuchung</td><td>Atomische service/test/observatie (testcode of behandelingcode)</td></tr><tr><td>C</td><td>Berechnetes Einzelergebnis</td><td>Enkelvoudige observatie berekend via regels of formule uit andere onafhankelijke observaties (bijv. Alveolair--arteriële gradiënt, hart-minuut-volume)</td></tr><tr><td>F</td><td>Funktionstest</td><td>Functionele procedure die kan bestaan uit een of meer gerelateerde metingen (bijv. glucosetolerantietest, creatinineklaring),  meestal uitgevoerd op verschillende momenten en/of verschillende monsters</td></tr><tr><td>P</td><td>Batterieanordnung</td><td>Profiel of battery bestaande uit vele onafhankelijke atomische observaties (bijv. SMA12, electrolyten), meestal met één instrument op één monster</td></tr><tr><td>S</td><td>Latte von mehreren Batterieanforderungen (Aufnahmelatte)</td><td>Superset--een set batteries of procedures aangevraagd onder een enkele aanvraagcode maar behandeld als afzonderlijke batteries (bijv. routines = CBC, UA, electrolyten); Deze set geeft aan dat de bedoelde code wordt gebruikt voor het aanvragen van meerdere services/tests/observaties</td></tr></table></div>
  </text>
  <extension url="http://hl7.org/fhir/StructureDefinition/valueset-oid">
    <valueUri value="urn:oid:2.16.840.1.133883.18.90"/>
  </extension>
  <extension url="http://hl7.org/fhir/StructureDefinition/package-source">
    <extension url="packageId">
      <valueId value="hl7.fhir.uv.xver-r2.r5"/>
    </extension>
    <extension url="version">
      <valueString value="0.1.0"/>
    </extension>
    <extension url="uri">
      <valueUri
                value="http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r2.r5"/>
    </extension>
  </extension>
  <extension
             url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
    <valueCode value="fhir"/>
  </extension>
  <extension
             url="http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm">
    <valueInteger value="0">
      <extension
                 url="http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom">
        <valueCanonical
                        value="http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r2.r5"/>
      </extension>
    </valueInteger>
  </extension>
  <extension
             url="http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status">
    <valueCode value="trial-use">
      <extension
                 url="http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom">
        <valueCanonical
                        value="http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r2.r5"/>
      </extension>
    </valueCode>
  </extension>
  <url value="http://hl7.org/fhir/v2/0174"/>
  <version value="1.0.2"/>
  <name value="v2-0174"/>
  <status value="draft"/>
  <date value="2026-03-20T11:35:48+11:00"/>
  <publisher value="FHIR Infrastructure"/>
  <contact>
    <name value="FHIR Infrastructure"/>
    <telecom>
      <system value="url"/>
      <value value="http://www.hl7.org/Special/committees/fiwg"/>
    </telecom>
  </contact>
  <jurisdiction>
    <coding>
      <system value="http://unstats.un.org/unsd/methods/m49/m49.htm"/>
      <code value="001"/>
      <display value="World"/>
    </coding>
  </jurisdiction>
  <caseSensitive value="false"/>
  <content value="complete"/>
  <property>
    <code value="status"/>
    <uri value="http://hl7.org/fhir/concept-properties#status"/>
    <type value="code"/>
  </property>
  <property>
    <code value="inactive"/>
    <uri value="http://hl7.org/fhir/concept-properties#inactive"/>
    <type value="boolean"/>
  </property>
  <property>
    <code value="effectiveDate"/>
    <uri value="http://hl7.org/fhir/concept-properties#effectiveDate"/>
    <type value="dateTime"/>
  </property>
  <property>
    <code value="deprecationDate"/>
    <uri value="http://hl7.org/fhir/concept-properties#deprecationDate"/>
    <type value="dateTime"/>
  </property>
  <property>
    <code value="retirementDate"/>
    <uri value="http://hl7.org/fhir/concept-properties#retirementDate"/>
    <type value="dateTime"/>
  </property>
  <property>
    <code value="notSelectable"/>
    <uri value="http://hl7.org/fhir/concept-properties#notSelectable"/>
    <type value="boolean"/>
  </property>
  <property>
    <code value="parent"/>
    <uri value="http://hl7.org/fhir/concept-properties#parent"/>
    <type value="code"/>
  </property>
  <property>
    <code value="child"/>
    <uri value="http://hl7.org/fhir/concept-properties#child"/>
    <type value="code"/>
  </property>
  <property>
    <code value="partOf"/>
    <uri value="http://hl7.org/fhir/concept-properties#partOf"/>
    <type value="code"/>
  </property>
  <property>
    <code value="synonym"/>
    <uri value="http://hl7.org/fhir/concept-properties#synonym"/>
    <type value="code"/>
  </property>
  <property>
    <code value="comment"/>
    <uri value="http://hl7.org/fhir/concept-properties#comment"/>
    <type value="string"/>
  </property>
  <property>
    <code value="itemWeight"/>
    <uri value="http://hl7.org/fhir/concept-properties#itemWeight"/>
    <type value="decimal"/>
  </property>
  <concept>
    <code value="A"/>
    <display
             value="Atomic service/test/observation (test code or treatment code)"/>
    <designation>
      <language value="de"/>
      <value value="Einzeluntersuchung"/>
    </designation>
    <designation>
      <language value="nl"/>
      <value
             value="Atomische service/test/observatie (testcode of behandelingcode)"/>
    </designation>
  </concept>
  <concept>
    <code value="C"/>
    <display
             value="Single observation calculated via a rule or formula from other independent observations (e.g. Alveolar-arterial ratio, cardiac output)"/>
    <designation>
      <language value="de"/>
      <value value="Berechnetes Einzelergebnis"/>
    </designation>
    <designation>
      <language value="nl"/>
      <value
             value="Enkelvoudige observatie berekend via regels of formule uit andere onafhankelijke observaties (bijv. Alveolair--arteriële gradiënt, hart-minuut-volume)"/>
    </designation>
  </concept>
  <concept>
    <code value="F"/>
    <display
             value="Functional procedure that may consist of one or more interrelated measures (e.g. glucose tolerance test, creatinine clearance), usually done at different times and/or on different specimens"/>
    <designation>
      <language value="de"/>
      <value value="Funktionstest"/>
    </designation>
    <designation>
      <language value="nl"/>
      <value
             value="Functionele procedure die kan bestaan uit een of meer gerelateerde metingen (bijv. glucosetolerantietest, creatinineklaring),  meestal uitgevoerd op verschillende momenten en/of verschillende monsters"/>
    </designation>
  </concept>
  <concept>
    <code value="P"/>
    <display
             value="Profile or battery consisting of many independent atomic observations (e.g. SMA12, electrolytes), usually done at one instrument on one specimen"/>
    <designation>
      <language value="de"/>
      <value value="Batterieanordnung"/>
    </designation>
    <designation>
      <language value="nl"/>
      <value
             value="Profiel of battery bestaande uit vele onafhankelijke atomische observaties (bijv. SMA12, electrolyten), meestal met één instrument op één monster"/>
    </designation>
  </concept>
  <concept>
    <code value="S"/>
    <display
             value="Superset-a set of batteries or procedures ordered under a single code unit but processed as separate batteries (e.g. routines = CBC, UA, electrolytes)&lt;p&gt;This set indicates that the code being described is used to order multiple service/test/observation b"/>
    <designation>
      <language value="de"/>
      <value
             value="Latte von mehreren Batterieanforderungen (Aufnahmelatte)"/>
    </designation>
    <designation>
      <language value="nl"/>
      <value
             value="Superset--een set batteries of procedures aangevraagd onder een enkele aanvraagcode maar behandeld als afzonderlijke batteries (bijv. routines = CBC, UA, electrolyten); Deze set geeft aan dat de bedoelde code wordt gebruikt voor het aanvragen van meerdere services/tests/observaties"/>
    </designation>
  </concept>
</CodeSystem>