Extensions for Using Data Elements from FHIR DSTU2 in FHIR R5
0.1.0 - STU International flag

Extensions for Using Data Elements from FHIR DSTU2 in FHIR R5 - Downloaded Version null See the Directory of published versions

CodeSystem: v2-0065

Official URL: http://hl7.org/fhir/v2/0065 Version: 1.0.2
Standards status: Trial-use Maturity Level: 0 Computable Name: v2-0065

This Code system is referenced in the content logical definition of the following value sets:

Properties

This code system defines the following properties for its concepts

NameCodeURIType
Status status http://hl7.org/fhir/concept-properties#status code
Inactive inactive http://hl7.org/fhir/concept-properties#inactive boolean
effectiveDate effectiveDate http://hl7.org/fhir/concept-properties#effectiveDate dateTime
Deprecation Date deprecationDate http://hl7.org/fhir/concept-properties#deprecationDate dateTime
Retirement Date retirementDate http://hl7.org/fhir/concept-properties#retirementDate dateTime
Not Selectable notSelectable http://hl7.org/fhir/concept-properties#notSelectable boolean
Parent parent http://hl7.org/fhir/concept-properties#parent code
Child child http://hl7.org/fhir/concept-properties#child code
Part Of partOf http://hl7.org/fhir/concept-properties#partOf code
Synonym synonym http://hl7.org/fhir/concept-properties#synonym code
Comment comment http://hl7.org/fhir/concept-properties#comment string
itemWeight itemWeight http://hl7.org/fhir/concept-properties#itemWeight decimal

Concepts

This case-insensitive code system http://hl7.org/fhir/v2/0065 defines the following codes:

CodeDisplay
A Add ordered tests to the existing specimen
C Cancel order for battery or tests named
G Generated order; reflex order
L Lab to obtain specimen from patient
O Specimen obtained by service other than Lab
P Pending specimen; Order sent prior to delivery
R Revised order
S Schedule the tests specified below

Additional Language Displays

CodeDeutsch (German, de)Nederlands (Dutch, nl)
A Zusätzliche Tests zur vorhandenen Probe Voeg gevraagde tests toe aan bestaande monster
C Stornoauftrag zu bekannter Probe Annuleer aanvraag voor genoemde battery of tests
G Nachgeordneter Auftrag / Auftrag als Reaktion auf Untersuchungsergebnis Gegenereerde aanvraag / reflexaanvraag
L Holauftrag für Labor Lab verzamelt monster van patiënt
O Probe wird / wurde mit dem Auftrag zur Verfügung gestellt Monster wordt afgenomen door een service anders dan het Lab
P Probe steht noch aus - Auftrag liegt schon vor Wachtend op monster - Aanvraag gestuurd voorafgaand aan levering
R Geänderter Auftrag Herziene aanvraag
S Spezifizierte Untersuchungen einplanen Plan de tests zoals hieronder gespecificeerd