HL7 Version 2 to FHIR
1.0.0-ballot - ballot International flag

This page is part of the HL7 Version 2 to FHIR (v1.0.0-ballot: STU1 Ballot 1) based on FHIR (HL7® FHIR® Standard) R4. . For a full list of available versions, see the Directory of published versions

ConceptMap: Table HL70085 to Observation Status Map (Experimental)

Official URL: http://hl7.org/fhir/uv/v2mappings/table-hl70085-to-observation-status Version: 1.0.0-ballot
Active as of 2023-12-19 Computable Name: TableHL70085ToObservationStatus

Copyright/Legal: Copyright (c) 2020, HL7 International, Inc., All Rights Reserved.

This ConceptMap represents a mapping from the HL7 V2 Table HL70085 to the FHIR Observation Status Value Set.

This ConceptMap represents the mapping from the HL7 V2 Table HL70085 to the FHIR Observation Status Value Set. See also the FHIR Shorthand or the CSV Source.

HL7 v2Condition (IF True, args)HL7 FHIRComments
CodeTextCode SystemComputable ANTLRComputable FHIRPathNarrativeCodeProposed ExtensionDisplayCode System
AAmended HL70085amendedAmendedhttp://hl7.org/fhir/observation-status
BAppended HL70085
CCorrection HL70085correctedCorrectedhttp://hl7.org/fhir/observation-status
DDeletedHL70085entered-in-errorEntered in Errorhttp://hl7.org/fhir/observation-status
FFinalHL70085finalFinalhttp://hl7.org/fhir/observation-status
ISpecimen in Lab; results pendingHL70085 Registeredhttp://hl7.org/fhir/observation-status
NNot AskedHL70085Depedending on context
OOrder DetailHL70085
PPreliminaryHL70085preliminaryPreliminaryhttp://hl7.org/fhir/observation-status
REntered - Not VerifiedHL70085
SPartialHL70085
VVerifiedHL70085Create JIRA: Final results reviewed and confirmed to be correct, no change to result value, normal range or abnormal flag
XCannot be ObtainedHL70085cancelledhttp://hl7.org/fhir/observation-status
UStatus Change to Final Without RetransmissionHL70085
WOriginal Posted as WrongHL70085entered-in-errorEntered in Errorhttp://hl7.org/fhir/observation-status
now
draft update

Mapping from HL70085 to http://hl7.org/fhir/observation-status

ACTIVE (not intended for production usage). Published on 2023-12-19 by HL7 International / Orders and Observations (HL7 Orders and Observations Workgroup: http://www.hl7.org/Special/com..., Keith W. Boone: kboone@ainq.com, Rob Hausam: rrhausam@gmail.com). Copyright (c) 2020, HL7 International, Inc., All Rights Reserved.

This ConceptMap represents a mapping from the HL7 V2 Table HL70085 to the FHIR Observation Status Value Set.


Group 1Mapping from unspecified code system to unspecified code system

Source CodeRelationshipTarget Code
A (Amended)amended
B (Appended)(not mapped)
C (Correction)corrected
D (Deleted)entered-in-error
F (Final)final
I (Specimen in Lab; results pending)
N (Not Asked)(not mapped)
O (Order Detail)(not mapped)
P (Preliminary)preliminary
R (Entered - Not Verified)(not mapped)
S (Partial)(not mapped)
V (Verified)(not mapped)
X (Cannot be Obtained)cancelled
U (Status Change to Final Without Retransmission)(not mapped)
W (Original Posted as Wrong)entered-in-error

Notes: