HL7 Version 2 to FHIR
0.1.0 - STU1 Ballot

This page is part of the HL7 Version 2 to FHIR (v0.1.0: STU 1 Ballot 1) based on FHIR R4. . For a full list of available versions, see the Directory of published versions

: Segment PR1 to Procedure Map - JSON Representation

Raw json | Download

{
  "resourceType" : "ConceptMap",
  "id" : "segment-pr1-to-procedure",
  "text" : {
    "status" : "extensions",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><h2>SegmentPR1toProcedure (http://hl7.org/fhir/uv/v2mappings/segment-pr1-to-procedure)</h2><p>Mapping from PR1 to <a href=\"http://hl7.org/fhir/R4/procedure.html\">Procedure</a></p><p>ACTIVE (not intended for production usage). Published on 2020-08-12 by HL7 International (HL7 Orders and Observations Workgroup: <a href=\"http://hl7.org/Special/committees/orders/index.cfm\">http://hl7.org/Special/committ...</a>, Keith W. Boone: <a href=\"mailto:kboone@ainq.com\">kboone@ainq.com</a>). Copyright (c) 2020, HL7 International, Inc., All Rights Reserved.</p><div><p>This ConceptMap represents a mapping from the HL7 V2 Segment PR1 to the FHIR Procedure Resource.</p>\n</div><br/><table class=\"grid\"><tr><td colspan=\"4\"><b>Source Concept Details</b></td><td><b>Relationship</b></td><td colspan=\"3\"><b>Destination Concept Details</b></td></tr><tr><td colspan=\"2\"><b>Code</b> from </td><td><b>Code</b> from </td><td><b>Code</b> from </td><td/><td colspan=\"2\"><b>Code</b> from </td><td><b>Code</b> from </td></tr><tr><td style=\"border-right-width: 0px\">PR1-3</td><td style=\"border-left-width: 0px\"></td><td>CNE[CodeableConcept]</td><td/><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">code</td><td style=\"border-left-width: 0px\"></td><td/></tr><tr><td style=\"border-right-width: 0px\">PR1-4</td><td style=\"border-left-width: 0px\"></td><td/><td/><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">code.text</td><td style=\"border-left-width: 0px\"></td><td>IF PR1-3.9 NOT VALUED</td></tr><tr><td style=\"border-right-width: 0px\">PR1-5</td><td style=\"border-left-width: 0px\"></td><td/><td/><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">performedDateTime</td><td style=\"border-left-width: 0px\"></td><td>IF PR1-7 NOT VALUED</td></tr><tr><td style=\"border-right-width: 0px\">PR1-5</td><td style=\"border-left-width: 0px\"></td><td/><td/><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">performedDateTime</td><td style=\"border-left-width: 0px\"></td><td>IF PR1-7 VALUED AND PR1-5.5 NOT VALUED</td></tr><tr><td style=\"border-right-width: 0px\">PR1-5</td><td style=\"border-left-width: 0px\"></td><td/><td/><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">performedPeriod.start</td><td style=\"border-left-width: 0px\"></td><td>IF PR1-7 VALUED AND PR1-5.5 VALUED</td></tr><tr><td style=\"border-right-width: 0px\">PR1-6</td><td style=\"border-left-width: 0px\"></td><td>CWE[CodeableConcept]</td><td/><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">category</td><td style=\"border-left-width: 0px\"></td><td/></tr><tr><td style=\"border-right-width: 0px\">PR1-7</td><td style=\"border-left-width: 0px\"></td><td/><td>Procedure.performedPeriod.start+PR1-7</td><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">performedPeriod.end</td><td style=\"border-left-width: 0px\"></td><td>IF PR1-5.5 IS VALUED</td></tr><tr><td style=\"border-right-width: 0px\">PR1-8</td><td style=\"border-left-width: 0px\"></td><td>XCN[Practitioner]</td><td/><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">perfomer[1].actor(Practitioner)</td><td style=\"border-left-width: 0px\"></td><td/></tr><tr><td style=\"border-right-width: 0px\">PR1-8</td><td style=\"border-left-width: 0px\"></td><td/><td>&quot;88189002&quot;</td><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">perfomer[1].function.coding.code</td><td style=\"border-left-width: 0px\"></td><td/></tr><tr><td style=\"border-right-width: 0px\">PR1-8</td><td style=\"border-left-width: 0px\"></td><td/><td>&quot;http://snomed.info/sct&quot;</td><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">perfomer[1].function.coding.uri</td><td style=\"border-left-width: 0px\"></td><td/></tr><tr><td style=\"border-right-width: 0px\">PR1-11</td><td style=\"border-left-width: 0px\"></td><td>XCN[Practitioner]</td><td/><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">perfomer[2].actor(Practitioner)</td><td style=\"border-left-width: 0px\"></td><td/></tr><tr><td style=\"border-right-width: 0px\">PR1-11</td><td style=\"border-left-width: 0px\"></td><td/><td>&quot;304292004&quot;</td><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">perfomer[2].function.coding.code</td><td style=\"border-left-width: 0px\"></td><td/></tr><tr><td style=\"border-right-width: 0px\">PR1-11</td><td style=\"border-left-width: 0px\"></td><td/><td>&quot;http://snomed.info/sct&quot;</td><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">perfomer[2].function.coding.uri</td><td style=\"border-left-width: 0px\"></td><td/></tr><tr><td style=\"border-right-width: 0px\">PR1-12</td><td style=\"border-left-width: 0px\"></td><td>XCN[Practitioner]</td><td/><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">perfomer[3].actor(Practitioner)</td><td style=\"border-left-width: 0px\"></td><td/></tr><tr><td style=\"border-right-width: 0px\">PR1-12</td><td style=\"border-left-width: 0px\"></td><td/><td>&quot;http://snomed.info/sct&quot;</td><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">perfomer[3].function.coding.uri</td><td style=\"border-left-width: 0px\"></td><td/></tr><tr><td style=\"border-right-width: 0px\">PR1-15</td><td style=\"border-left-width: 0px\"></td><td>CWE[CodeableConcept]</td><td/><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">reasonCode</td><td style=\"border-left-width: 0px\"></td><td/></tr><tr><td style=\"border-right-width: 0px\">PR1-19</td><td style=\"border-left-width: 0px\"></td><td>EI[Identifier]</td><td/><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">identifier</td><td style=\"border-left-width: 0px\"></td><td/></tr><tr><td style=\"border-right-width: 0px\">PR1-23</td><td style=\"border-left-width: 0px\"></td><td>PL[Location]</td><td/><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">location(Location)</td><td style=\"border-left-width: 0px\"></td><td/></tr><tr><td style=\"border-right-width: 0px\">PR1-25</td><td style=\"border-left-width: 0px\"></td><td>EI[Identifier]</td><td/><td><a href=\"http://hl7.org/fhir/R4/codesystem-concept-map-equivalence.html#equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">partOf(Procedure.identifier)</td><td style=\"border-left-width: 0px\"></td><td/></tr></table></div>"
  },
  "extension" : [
    {
      "extension" : [
        {
          "url" : "type",
          "valueCode" : "derived-from"
        },
        {
          "url" : "label",
          "valueString" : "Segment PR1 to Procedure.fsh"
        },
        {
          "url" : "url",
          "valueUri" : "https://docs.google.com/spreadsheets/d/12jwNxyJ4zvjtbYbDGgnd_Pg7GsuG0iQK3TlJtDsADOU/edit#gid=0"
        }
      ],
      "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/RelatedArtifact"
    }
  ],
  "url" : "http://hl7.org/fhir/uv/v2mappings/segment-pr1-to-procedure",
  "version" : "0.1.0",
  "name" : "SegmentPR1toProcedure",
  "status" : "active",
  "experimental" : true,
  "date" : "2020-08-12",
  "publisher" : "HL7 International",
  "contact" : [
    {
      "name" : "HL7 Orders and Observations Workgroup",
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://hl7.org/Special/committees/orders/index.cfm"
        }
      ]
    },
    {
      "name" : "Keith W. Boone",
      "telecom" : [
        {
          "system" : "email",
          "value" : "kboone@ainq.com"
        }
      ]
    }
  ],
  "description" : "This ConceptMap represents a mapping from the HL7 V2 Segment PR1 to the FHIR Procedure Resource.",
  "jurisdiction" : [
    {
      "coding" : [
        {
          "system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code" : "001"
        }
      ]
    }
  ],
  "copyright" : "Copyright (c) 2020, HL7 International, Inc., All Rights Reserved.",
  "sourceUri" : "PR1",
  "targetUri" : "Procedure",
  "group" : [
    {
      "element" : [
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "CNE"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : -1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : -1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PR1-3",
          "display" : "Procedure Code",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "CodeableConcept"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "code",
              "display" : "code",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "data-type-map",
                  "value" : "CNE[CodeableConcept]"
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "ST"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : -1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : -1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PR1-4",
          "display" : "Procedure Description",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "string"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "code.text",
              "display" : "code.text",
              "equivalence" : "equivalent",
              "product" : [
                {
                  "property" : "antlr",
                  "value" : "IF PR1-3.9 NOT VALUED"
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "DTM"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : 1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : 1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PR1-5",
          "display" : "Procedure Date/Time",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "dateTime"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "performedDateTime",
              "display" : "performedDateTime",
              "equivalence" : "equivalent",
              "product" : [
                {
                  "property" : "antlr",
                  "value" : "IF PR1-7 NOT VALUED"
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "DTM"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : 1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : 1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PR1-5",
          "display" : "Procedure Date/Time",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "dateTime"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "performedDateTime",
              "display" : "performedDateTime",
              "equivalence" : "equivalent",
              "product" : [
                {
                  "property" : "antlr",
                  "value" : "IF PR1-7 VALUED AND PR1-5.5 NOT VALUED"
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "DTM"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : 1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : 1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PR1-5",
          "display" : "Procedure Date/Time",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "dateTime"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "performedPeriod.start",
              "display" : "performedPeriod.start",
              "equivalence" : "equivalent",
              "product" : [
                {
                  "property" : "antlr",
                  "value" : "IF PR1-7 VALUED AND PR1-5.5 VALUED"
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "CWE"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : 1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : 1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PR1-6",
          "display" : "Procedure Functional Type",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "CodeableConcept"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "category",
              "display" : "category",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "data-type-map",
                  "value" : "CWE[CodeableConcept]"
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "NM"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : 1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : 1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PR1-7",
          "display" : "Procedure Minutes",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "dateTime"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "performedPeriod.end",
              "display" : "performedPeriod.end",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "value",
                  "value" : "Procedure.performedPeriod.start+PR1-7"
                }
              ],
              "product" : [
                {
                  "property" : "antlr",
                  "value" : "IF PR1-5.5 IS VALUED"
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "XCN"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : -1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : -1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PR1-8",
          "display" : "Anesthesiologist",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "Reference(Practitioner)"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "perfomer[1].actor(Practitioner)",
              "display" : "perfomer[1].actor(Practitioner)",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "data-type-map",
                  "value" : "XCN[Practitioner]"
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "XCN"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : -1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : -1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PR1-8",
          "display" : "Anesthesiologist",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "CodeableConcept"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "perfomer[1].function.coding.code",
              "display" : "perfomer[1].function.coding.code",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "value",
                  "value" : "\"88189002\""
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "XCN"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : -1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : -1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PR1-8",
          "display" : "Anesthesiologist",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "uri"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "perfomer[1].function.coding.uri",
              "display" : "perfomer[1].function.coding.uri",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "value",
                  "value" : "\"http://snomed.info/sct\""
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "XCN"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : -1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : -1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PR1-11",
          "display" : "Surgeon",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "Reference(Practitioner)"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "perfomer[2].actor(Practitioner)",
              "display" : "perfomer[2].actor(Practitioner)",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "data-type-map",
                  "value" : "XCN[Practitioner]"
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "XCN"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : -1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : -1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PR1-11",
          "display" : "Surgeon",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "CodeableConcept"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "perfomer[2].function.coding.code",
              "display" : "perfomer[2].function.coding.code",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "value",
                  "value" : "\"304292004\""
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "XCN"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : -1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : -1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PR1-11",
          "display" : "Surgeon",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "uri"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "perfomer[2].function.coding.uri",
              "display" : "perfomer[2].function.coding.uri",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "value",
                  "value" : "\"http://snomed.info/sct\""
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "XCN"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : -1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : -1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PR1-12",
          "display" : "Procedure Practitioner",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "Reference(Practitioner)"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "perfomer[3].actor(Practitioner)",
              "display" : "perfomer[3].actor(Practitioner)",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "data-type-map",
                  "value" : "XCN[Practitioner]"
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "XCN"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : -1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : -1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PR1-12",
          "display" : "Procedure Practitioner",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "uri"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "perfomer[3].function.coding.uri",
              "display" : "perfomer[3].function.coding.uri",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "value",
                  "value" : "\"http://snomed.info/sct\""
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "CWE"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : 1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : 1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PR1-15",
          "display" : "Associated Diagnosis Code",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "CodeableConcept"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : -1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "reasonCode",
              "display" : "reasonCode",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "data-type-map",
                  "value" : "CWE[CodeableConcept]"
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "EI"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : 1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : 1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PR1-19",
          "display" : "Procedure Identifier",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "Identifier"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : -1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "identifier",
              "display" : "identifier",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "data-type-map",
                  "value" : "EI[Identifier]"
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "PL"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : -1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : -1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PR1-23",
          "display" : "Treating Organizational Unit",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "Reference(Location)"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "location(Location)",
              "display" : "location(Location)",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "data-type-map",
                  "value" : "PL[Location]"
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "EI"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : 1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : 1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PR1-25",
          "display" : "Parent Procedure ID",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "Reference(Procedure)"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : -1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "partOf(Procedure.identifier)",
              "display" : "partOf(Procedure.identifier)",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "data-type-map",
                  "value" : "EI[Identifier]"
                }
              ]
            }
          ]
        }
      ]
    }
  ]
}