Point-of-Care Device Implementation Guide
0.3.0 - STU 1 Ballot

This page is part of the Point-of-care Device FHIR IG (v0.3.0: STU 1 Ballot 3) based on FHIR R4. . For a full list of available versions, see the Directory of published versions

: ECG Sample Array metric example - TTL Representation

Raw ttl | Download


@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

 a fhir:DeviceMetric;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "ECGSampleArrayDeviceMetric"];
  fhir:Resource.meta [
     fhir:Meta.profile [
       fhir:value "http://hl7.org/fhir/uv/pocd/StructureDefinition/SampleArrayDeviceMetric";
       fhir:index 0;
       fhir:link <http://hl7.org/fhir/uv/pocd/StructureDefinition/SampleArrayDeviceMetric>     ]
  ];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "extensions" ];
     fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><p><b>Resolution extension</b>: 0.001</p><p><b>Sweep Speed extension</b>: 25 mm/s</p><p><b>type</b>: <span title=\"Codes: {urn:iso:std:iso:11073:10101 131328}\">ECG</span></p><p><b>unit</b>: <span title=\"Codes: {urn:iso:std:iso:11073:10101 266418}\">mV</span></p><p><b>source</b>: <a href=\"Device-PhysioMonitorMdsDevice.html\">Generated Summary: id: 01-23-45-67-89-AB-CD-EF; status: active; manufacturer: MyCompany; serialNumber: 123456; modelNumber: PM1; <span title=\"Codes: {urn:iso:std:iso:11073:10101 69965}\">Patient Monitor</span></a></p><p><b>parent</b>: <a href=\"Device-ECGChannelDevice.html\">Generated Summary: status: active; <span title=\"Codes: {urn:iso:std:iso:11073:10101 69799}\">MDC_DEV_ECG_CHAN</span></a></p><p><b>operationalStatus</b>: on</p><p><b>color</b>: green</p><p><b>category</b>: measurement</p></div>"
  ];
  fhir:DomainResource.extension [
     fhir:index 0;
     fhir:Extension.url [ fhir:value "http://hl7.org/fhir/uv/pocd/StructureDefinition/resolution" ];
     fhir:Extension.valueDecimal [ fhir:value "0.001"^^xsd:decimal ]
  ], [
     fhir:index 1;
     fhir:Extension.url [ fhir:value "http://hl7.org/fhir/uv/pocd/StructureDefinition/sweep-speed" ];
     fhir:Extension.valueQuantity [
       fhir:Quantity.value [ fhir:value "25"^^xsd:decimal ];
       fhir:Quantity.unit [ fhir:value "mm/s" ];
       fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
       fhir:Quantity.code [ fhir:value "mm/s" ]     ]
  ];
  fhir:DeviceMetric.type [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       fhir:Coding.system [ fhir:value "urn:iso:std:iso:11073:10101" ];
       fhir:Coding.code [ fhir:value "131328" ];
       fhir:Coding.display [ fhir:value "MDC_ECG_ELEC_POTL" ]     ];
     fhir:CodeableConcept.text [ fhir:value "ECG" ]
  ];
  fhir:DeviceMetric.unit [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       fhir:Coding.system [ fhir:value "urn:iso:std:iso:11073:10101" ];
       fhir:Coding.code [ fhir:value "266418" ];
       fhir:Coding.display [ fhir:value "MDC_DIM_MILLI_VOLT" ]     ];
     fhir:CodeableConcept.text [ fhir:value "mV" ]
  ];
  fhir:DeviceMetric.source [
     fhir:Reference.reference [ fhir:value "Device/PhysioMonitorMdsDevice" ]
  ];
  fhir:DeviceMetric.parent [
     fhir:Reference.reference [ fhir:value "Device/ECGChannelDevice" ]
  ];
  fhir:DeviceMetric.operationalStatus [ fhir:value "on"];
  fhir:DeviceMetric.color [ fhir:value "green"];
  fhir:DeviceMetric.category [ fhir:value "measurement"].

# - ontology header ------------------------------------------------------------

 a owl:Ontology;
  owl:imports fhir:fhir.ttl.