This page is part of the Point-of-care Device FHIR IG (v0.3.0: STU 1 Ballot 3) based on FHIR R4. . For a full list of available versions, see the Directory of published versions
{
"resourceType" : "Device",
"id" : "PhysioMonitorMdsDevice",
"meta" : {
"profile" : [
"http://hl7.org/fhir/uv/pocd/StructureDefinition/MdsDevice"
]
},
"text" : {
"status" : "extensions",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><p><b>Approved Jurisdictions extension</b>: <span title=\"Codes: {urn:iso:std:iso:3166 840}\">United States of America</span></p><p><b>Operator extension</b>: <a href=\"Practitioner-SomePractitioner.html\">Generated Summary: active; Alice B. Careful </a></p><p><b>Operating hours extension</b>: 8760</p><p><b>Operating cycles extension</b>: 156</p><p><b>Operating mode extension</b>: Dmo</p><p><b>identifier</b>: id: 01-23-45-67-89-AB-CD-EF</p><h3>UdiCarriers</h3><table class=\"grid\"><tr><td>-</td><td><b>DeviceIdentifier</b></td><td><b>CarrierHRF</b></td></tr><tr><td>*</td><td>00012345678905</td><td>(01)00012345678905(21)123456</td></tr></table><p><b>status</b>: active</p><p><b>manufacturer</b>: MyCompany</p><p><b>serialNumber</b>: 123456</p><h3>DeviceNames</h3><table class=\"grid\"><tr><td>-</td><td><b>Name</b></td><td><b>Type</b></td></tr><tr><td>*</td><td>MyPhysioMonitor</td><td>model-name</td></tr></table><p><b>modelNumber</b>: PM1</p><p><b>type</b>: <span title=\"Codes: {urn:iso:std:iso:11073:10101 69965}\">Patient Monitor</span></p><p><b>patient</b>: <a href=\"Patient-SomePatient.html\">Generated Summary: Medical record number: 0815; active; John Doe ; gender: male; birthDate: 1967-05-04</a></p><p><b>location</b>: <a href=\"Location-SomeLocation.html\">Generated Summary: name: Bed 42; mode: instance; <span title=\"Codes: {http://terminology.hl7.org/CodeSystem/v3-RoleCode ICU}\">Intensive care unit</span>; <span title=\"Codes: {http://terminology.hl7.org/CodeSystem/location-physical-type bd}\">Bed</span></a></p></div>"
},
"extension" : [
{
"url" : "http://hl7.org/fhir/uv/pocd/StructureDefinition/approved-jurisdictions",
"valueCodeableConcept" : {
"coding" : [
{
"system" : "urn:iso:std:iso:3166",
"code" : "840",
"display" : "United States of America"
}
]
}
},
{
"url" : "http://hl7.org/fhir/uv/pocd/StructureDefinition/operator",
"valueReference" : {
"reference" : "Practitioner/SomePractitioner"
}
},
{
"url" : "http://hl7.org/fhir/uv/pocd/StructureDefinition/operating-hours",
"valueUnsignedInt" : 8760
},
{
"url" : "http://hl7.org/fhir/uv/pocd/StructureDefinition/operating-cycles",
"valueUnsignedInt" : 156
},
{
"url" : "http://hl7.org/fhir/uv/pocd/StructureDefinition/operating-mode",
"valueCode" : "Dmo"
}
],
"identifier" : [
{
"system" : "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680",
"value" : "01-23-45-67-89-AB-CD-EF"
}
],
"udiCarrier" : [
{
"deviceIdentifier" : "00012345678905",
"carrierHRF" : "(01)00012345678905(21)123456"
}
],
"status" : "active",
"manufacturer" : "MyCompany",
"serialNumber" : "123456",
"deviceName" : [
{
"name" : "MyPhysioMonitor",
"type" : "model-name"
}
],
"modelNumber" : "PM1",
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "69965",
"display" : "MDC_DEV_MON_PHYSIO_MULTI_PARAM_MDS"
}
],
"text" : "Patient Monitor"
},
"patient" : {
"reference" : "Patient/SomePatient"
},
"location" : {
"reference" : "Location/SomeLocation"
}
}