Point-of-Care Device Implementation Guide
0.3.0 - STU 1 Ballot

This page is part of the Point-of-care Device FHIR IG (v0.3.0: STU 1 Ballot 3) based on FHIR R4. . For a full list of available versions, see the Directory of published versions

: NBP VMD example - TTL Representation

Raw ttl | Download


@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

 a fhir:Device;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "NBPVmdDevice"];
  fhir:Resource.meta [
     fhir:Meta.profile [
       fhir:value "http://hl7.org/fhir/uv/pocd/StructureDefinition/VmdDevice";
       fhir:index 0;
       fhir:link <http://hl7.org/fhir/uv/pocd/StructureDefinition/VmdDevice>     ]
  ];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ];
     fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><h3>UdiCarriers</h3><table class=\"grid\"><tr><td>-</td><td><b>DeviceIdentifier</b></td><td><b>CarrierHRF</b></td></tr><tr><td>*</td><td>00012345678912</td><td>(01)00012345678912(21)567890</td></tr></table><p><b>status</b>: active</p><p><b>manufacturer</b>: MyCompany</p><p><b>serialNumber</b>: 567890</p><p><b>partNumber</b>: 1122-3344</p><p><b>type</b>: <span title=\"Codes: {urn:iso:std:iso:11073:10101 70686}\">MDC_DEV_PRESS_BLD_NONINV_VMD</span></p><p><b>parent</b>: <a href=\"Device-PhysioMonitorMdsDevice.html\">Generated Summary: id: 01-23-45-67-89-AB-CD-EF; status: active; manufacturer: MyCompany; serialNumber: 123456; modelNumber: PM1; <span title=\"Codes: {urn:iso:std:iso:11073:10101 69965}\">Patient Monitor</span></a></p></div>"
  ];
  fhir:Device.udiCarrier [
     fhir:index 0;
     fhir:Device.udiCarrier.deviceIdentifier [ fhir:value "00012345678912" ];
     fhir:Device.udiCarrier.carrierHRF [ fhir:value "(01)00012345678912(21)567890" ]
  ];
  fhir:Device.status [ fhir:value "active"];
  fhir:Device.manufacturer [ fhir:value "MyCompany"];
  fhir:Device.serialNumber [ fhir:value "567890"];
  fhir:Device.partNumber [ fhir:value "1122-3344"];
  fhir:Device.type [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       fhir:Coding.system [ fhir:value "urn:iso:std:iso:11073:10101" ];
       fhir:Coding.code [ fhir:value "70686" ];
       fhir:Coding.display [ fhir:value "MDC_DEV_PRESS_BLD_NONINV_VMD" ]     ]
  ];
  fhir:Device.parent [
     fhir:Reference.reference [ fhir:value "Device/PhysioMonitorMdsDevice" ]
  ].

# - ontology header ------------------------------------------------------------

 a owl:Ontology;
  owl:imports fhir:fhir.ttl.