ValueSet: Device Type Specialization IEEE 11073-10101 Nomenclature Codes

Official URL: http://hl7.org/fhir/uv/phd/ValueSet/DeviceTypes11073MDC Version: 1.1.0
Active as of 2021-09-25 Computable Name: DeviceTypes11073MDC

ValueSet for the ISO/IEEE 11073-10101 Nomenclatures Describing Device specialization types such as blood pressure, pulse oximeter, thermometer, ecg, etc.. Nomenclature codes are 32-bit numbers where the upper 16 bits represent the partition and the lower 16 bits represent the term code. Most of the codes included in this value set are from partition infra which has value 8. THe 32-bit code for the pulse oximeter, which has term code 4100 in partition infra, is given by 524288 + 4100 = 528388. This value set will grow as new specializations are defined. The display value consists of the nomenclature code's reference identifier. Devices exchange the numerical codes in the IEEE 11073 communication standards, not reference identifiers, but the reference identifiers are often used where human readability are more important than efficiency or bandwidth. However, only the numerical codes are guaranteed to be unique.

References

This value set is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)

Logical Definition (CLD)

Generated Narrative: ValueSet DeviceTypes11073MDC

  • Include these codes as defined in urn:iso:std:iso:11073:10101
    CodeDisplay
    528388MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse oximeter
    528390MDC_DEV_SPEC_PROFILE_MIN_ECG: Electrocardiogram (ECG)
    528391MDC_DEV_SPEC_PROFILE_BP: Non-invasive Blood Pressure monitor
    528392MDC_DEV_SPEC_PROFILE_TEMP : Thermometer
    528397MDC_DEV_SPEC_PROFILE_RESP_RATE : Respiration rate monitor
    528399MDC_DEV_SPEC_PROFILE_SCALE : Weight scale
    528401MDC_DEV_SPEC_PROFILE_GLUCOSE: Glucose monitor
    528402MDC_DEV_SPEC_PROFILE_COAG: Coagulation meter
    528403MDC_DEV_SPEC_PROFILE_INSULIN_PUMP: Insulin pump
    528404MDC_DEV_SPEC_PROFILE_BCA: Body composition analyzer
    528405MDC_DEV_SPEC_PROFILE_BCA: Peak Flow meter
    528406MDC_DEV_SPEC_PROFILE_URINE: Urine analyzer
    528408MDC_DEV_SPEC_PROFILE_SABTE: Sleep Apnea and Breathing Therapy Equipment
    528409MDC_DEV_SPEC_PROFILE_CGM: Continuous Glucose Monitor
    528412MDC_DEV_SPEC_PROFILE_PSM: Power Status Monitor
    528413MDC_DEV_SPEC_PROFILE_SPIRO: Spirometer
    528425MDC_DEV_SPEC_PROFILE_HF_CARDIO: Cardiovascular exercise equipment
    528426MDC_DEV_SPEC_PROFILE_HF_STRENGH: Strength and fitness equipment
    528455MDC_DEV_SPEC_PROFILE_AI_ACTIVITY_HUB: Independent living hub
    528456MDC_DEV_SPEC_PROFILE_AI_NED_MINDER: Medication Monitor
    528457MDC_DEV_SPEC_PROFILE_GENERIC: Device following the 20601 standard but no specific specialization
    528484MDC_DEV_SUB_SPEC_PROFILE_STEP_COUNTER: Step counter
    528501MDC_DEV_SUB_SPEC_PROFILE_FALL_SENSOR: Fall sensor
    528502MDC_DEV_SUB_SPEC_PROFILE_PERS_SENSOR: Personal sensor
    528503MDC_DEV_SUB_SPEC_PROFILE_SMOKE_SENSOR: Smoke sensor
    528504MDC_DEV_SUB_SPEC_PROFILE_CO_SENSOR: Carbon Monoxide sensor
    528505MDC_DEV_SUB_SPEC_PROFILE_WATER_SENSOR: Water sensor
    528506MDC_DEV_SUB_SPEC_PROFILE_GAS_SENSOR: Gas sensor
    528507MDC_DEV_SUB_SPEC_PROFILE_MOTION_SENSOR: Motion sensor
    528508MDC_DEV_SUB_SPEC_PROFILE_PROPEXIT_SENSOR: Property Exit sensor
    528509MDC_DEV_SUB_SPEC_PROFILE_ENURESIS_SENSOR: Enuresis sensor
    528510MDC_DEV_SUB_SPEC_PROFILE_CONTACTCLOSURE_SENSOR: Contact Closure sensor
    528511MDC_DEV_SUB_SPEC_PROFILE_USAGE_SENSOR: Usage sensor
    528512MDC_DEV_SUB_SPEC_PROFILE_SWITCH_SENSOR: Switch sensor
    528513MDC_DEV_SUB_SPEC_PROFILE_DOSAGE_SENSOR: Dosage sensor
    528514MDC_DEV_SUB_SPEC_PROFILE_TEMP_SENSOR: Temperature sensor
    528524MDC_DEV_SUB_SPEC_PROFILE_ECG: ECG supporting waveforms
    528525MDC_DEV_SUB_SPEC_PROFILE_HR: ECG supporting just heart rate
    528532MDC_DEV_SUB_SPEC_PROFILE_CPAP: Specialized SABTE device providing CPAP (continuous positive airway pressure) manually set
    528533MDC_DEV_SUB_SPEC_PROFILE_CPAP_AUTO: Specialized SABTE device providing CPAP (continuous positive airway pressure) automatically
    528534MDC_DEV_SUB_SPEC_PROFILE_BPAP: Specialized SABTE device providing BPAP (Bi-level positive airway pressure) manually set
    528535MDC_DEV_SUB_SPEC_PROFILE_BPAP_AUTO: Specialized SABTE device providing BPAP (Bi-level positive airway pressure) automatically
    528536MDC_DEV_SUB_SPEC_PROFILE_ACSV: Specialized SABTE device providing ACSV (Anti-cyclic Servo Ventilation)

 

Expansion

Generated Narrative: ValueSet

Expansion based on codesystem ISO 11073-10101 Health informatics - Point-of-care version2023-04-26

This value set contains 42 concepts

CodeSystemDisplay
  528388urn:iso:std:iso:11073:10101MDC_DEV_SPEC_PROFILE_PULS_OXIM
  528390urn:iso:std:iso:11073:10101MDC_DEV_SPEC_PROFILE_ECG
  528391urn:iso:std:iso:11073:10101MDC_DEV_SPEC_PROFILE_BP
  528392urn:iso:std:iso:11073:10101MDC_DEV_SPEC_PROFILE_TEMP
  528397urn:iso:std:iso:11073:10101MDC_DEV_SPEC_PROFILE_CALC_PULM
  528399urn:iso:std:iso:11073:10101MDC_DEV_SPEC_PROFILE_SCALE
  528401urn:iso:std:iso:11073:10101MDC_DEV_SPEC_PROFILE_GLUCOSE
  528402urn:iso:std:iso:11073:10101MDC_DEV_SPEC_PROFILE_COAG
  528403urn:iso:std:iso:11073:10101MDC_DEV_SPEC_PROFILE_INSULIN_PUMP
  528404urn:iso:std:iso:11073:10101MDC_DEV_SPEC_PROFILE_BCA
  528405urn:iso:std:iso:11073:10101MDC_DEV_SPEC_PROFILE_PEFM
  528406urn:iso:std:iso:11073:10101MDC_DEV_SPEC_PROFILE_URINE_ANALYZER
  528408urn:iso:std:iso:11073:10101MDC_DEV_SPEC_PROFILE_SABTE
  528409urn:iso:std:iso:11073:10101MDC_DEV_SPEC_PROFILE_CGM
  528412urn:iso:std:iso:11073:10101MDC_DEV_SPEC_PROFILE_PSM
  528425urn:iso:std:iso:11073:10101MDC_DEV_SPEC_PROFILE_HF_CARDIO
  528426urn:iso:std:iso:11073:10101MDC_DEV_SPEC_PROFILE_HF_STRENGTH
  528455urn:iso:std:iso:11073:10101MDC_DEV_SPEC_PROFILE_AI_ACTIVITY_HUB
  528456urn:iso:std:iso:11073:10101MDC_DEV_SPEC_PROFILE_AI_MED_MINDER
  528457urn:iso:std:iso:11073:10101MDC_DEV_SPEC_PROFILE_GENERIC
  528484urn:iso:std:iso:11073:10101MDC_DEV_SUB_SPEC_PROFILE_STEP_COUNTER
  528501urn:iso:std:iso:11073:10101MDC_DEV_SUB_SPEC_PROFILE_FALL_SENSOR
  528502urn:iso:std:iso:11073:10101MDC_DEV_SUB_SPEC_PROFILE_PERS_SENSOR
  528503urn:iso:std:iso:11073:10101MDC_DEV_SUB_SPEC_PROFILE_SMOKE_SENSOR
  528504urn:iso:std:iso:11073:10101MDC_DEV_SUB_SPEC_PROFILE_CO_SENSOR
  528505urn:iso:std:iso:11073:10101MDC_DEV_SUB_SPEC_PROFILE_WATER_SENSOR
  528506urn:iso:std:iso:11073:10101MDC_DEV_SUB_SPEC_PROFILE_GAS_SENSOR
  528507urn:iso:std:iso:11073:10101MDC_DEV_SUB_SPEC_PROFILE_MOTION_SENSOR
  528508urn:iso:std:iso:11073:10101MDC_DEV_SUB_SPEC_PROFILE_PROPEXIT_SENSOR
  528509urn:iso:std:iso:11073:10101MDC_DEV_SUB_SPEC_PROFILE_ENURESIS_SENSOR
  528510urn:iso:std:iso:11073:10101MDC_DEV_SUB_SPEC_PROFILE_CONTACTCLOSURE_SENSOR
  528511urn:iso:std:iso:11073:10101MDC_DEV_SUB_SPEC_PROFILE_USAGE_SENSOR
  528512urn:iso:std:iso:11073:10101MDC_DEV_SUB_SPEC_PROFILE_SWITCH_SENSOR
  528513urn:iso:std:iso:11073:10101MDC_DEV_SUB_SPEC_PROFILE_DOSAGE_SENSOR
  528514urn:iso:std:iso:11073:10101MDC_DEV_SUB_SPEC_PROFILE_TEMP_SENSOR
  528524urn:iso:std:iso:11073:10101MDC_DEV_SUB_SPEC_PROFILE_ECG
  528525urn:iso:std:iso:11073:10101MDC_DEV_SUB_SPEC_PROFILE_HR
  528532urn:iso:std:iso:11073:10101MDC_DEV_SUB_SPEC_PROFILE_CPAP
  528533urn:iso:std:iso:11073:10101MDC_DEV_SUB_SPEC_PROFILE_CPAP_AUTO
  528534urn:iso:std:iso:11073:10101MDC_DEV_SUB_SPEC_PROFILE_BPAP
  528535urn:iso:std:iso:11073:10101MDC_DEV_SUB_SPEC_PROFILE_BPAP_AUTO
  528536urn:iso:std:iso:11073:10101MDC_DEV_SUB_SPEC_PROFILE_ACSV

Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code