Personal Health Device Implementation Guide
1.1.0 - STU 1.1 International flag

This page is part of the Personal Health Device FHIR IG (v1.1.0: STU 1) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions

: Example of a Gateway - JSON Representation

Raw json | Download

{
  "resourceType" : "Device",
  "id" : "phg-ecde3d4e58532d31.000000000000",
  "meta" : {
    "profile" : [
      🔗 "http://hl7.org/fhir/uv/phd/StructureDefinition/PhgDevice"
    ]
  },
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: Device phg-ecde3d4e58532d31.000000000000</b></p><a name=\"phg-ecde3d4e58532d31.000000000000\"> </a><a name=\"hcphg-ecde3d4e58532d31.000000000000\"> </a><a name=\"phg-ecde3d4e58532d31.000000000000-en-US\"> </a><p><b>identifier</b>: IEEE 11073 System Identifier/ec-de-3d-4e-58-53-2d-31, Bluetooth MAC address/3d-4e-58-53-2d-31, Ethernet MAC address/3d-4e-58-53-2d-35</p><p><b>type</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 531981}\">MDC_MOC_VMS_MDS_AHD</span></p><h3>Versions</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Type</b></td><td><b>Value</b></td></tr><tr><td style=\"display: none\">*</td><td><span title=\"Codes:{urn:iso:std:iso:11073:10101 532352}\">MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version</span></td><td>5.0</td></tr></table><blockquote><p><b>property</b></p><p><b>type</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 68220}\">MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol</span></p><p><b>valueCode</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 532226}\">MDC_TIME_SYNC_NTPV4:</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 532353}\">MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: certified device list as transport-specialization combo</span></p><p><b>valueCode</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD 4}\">Pulse Oximeter certified</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 532355}\">MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: certified Upload classes</span></p><p><b>valueCode</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS 0}\">observation-upload-soap</span>, <span title=\"Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS 3}\">observation-upload-hdata</span>, <span title=\"Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS 7}\">observation-upload-fhir</span>, <span title=\"Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS 2}\">capabilities</span>, <span title=\"Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS 6}\">aps</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 532354.0}\">regulation-status</span></p><p><b>valueCode</b>: <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}\">Device is not regulated</span></p></blockquote></div>"
  },
  "identifier" : [
    {
      "type" : {
        "coding" : [
          {
            "system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers",
            "code" : "SYSID"
          }
        ]
      },
      "system" : "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680",
      "value" : "ec-de-3d-4e-58-53-2d-31"
    },
    {
      "type" : {
        "coding" : [
          {
            "system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers",
            "code" : "BTMAC"
          }
        ]
      },
      "system" : "http://hl7.org/fhir/sid/eui-48/bluetooth",
      "value" : "3d-4e-58-53-2d-31"
    },
    {
      "type" : {
        "coding" : [
          {
            "system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers",
            "code" : "ETHMAC"
          }
        ]
      },
      "system" : "http://hl7.org/fhir/sid/eui-48/ethernet",
      "value" : "3d-4e-58-53-2d-35"
    }
  ],
  "type" : {
    "coding" : [
      {
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "531981"
      }
    ],
    "text" : "MDC_MOC_VMS_MDS_AHD"
  },
  "version" : [
    {
      "type" : {
        "coding" : [
          {
            "system" : "urn:iso:std:iso:11073:10101",
            "code" : "532352"
          }
        ],
        "text" : "MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version"
      },
      "value" : "5.0"
    }
  ],
  "property" : [
    {
      "type" : {
        "coding" : [
          {
            "system" : "urn:iso:std:iso:11073:10101",
            "code" : "68220"
          }
        ],
        "text" : "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"
      },
      "valueCode" : [
        {
          "coding" : [
            {
              "system" : "urn:iso:std:iso:11073:10101",
              "code" : "532226"
            }
          ],
          "text" : "MDC_TIME_SYNC_NTPV4:"
        }
      ]
    },
    {
      "type" : {
        "coding" : [
          {
            "system" : "urn:iso:std:iso:11073:10101",
            "code" : "532353"
          }
        ],
        "text" : "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: certified device list as transport-specialization combo"
      },
      "valueCode" : [
        {
          "coding" : [
            {
              "system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD",
              "code" : "4"
            }
          ]
        }
      ]
    },
    {
      "type" : {
        "coding" : [
          {
            "system" : "urn:iso:std:iso:11073:10101",
            "code" : "532355"
          }
        ],
        "text" : "MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: certified Upload classes"
      },
      "valueCode" : [
        {
          "coding" : [
            {
              "system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS",
              "code" : "0"
            }
          ]
        },
        {
          "coding" : [
            {
              "system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS",
              "code" : "3"
            }
          ]
        },
        {
          "coding" : [
            {
              "system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS",
              "code" : "7"
            }
          ]
        },
        {
          "coding" : [
            {
              "system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS",
              "code" : "2"
            }
          ]
        },
        {
          "coding" : [
            {
              "system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS",
              "code" : "6"
            }
          ]
        }
      ]
    },
    {
      "type" : {
        "coding" : [
          {
            "system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7",
            "code" : "532354.0"
          }
        ],
        "text" : "regulation-status"
      },
      "valueCode" : [
        {
          "coding" : [
            {
              "system" : "http://terminology.hl7.org/CodeSystem/v2-0136",
              "code" : "Y"
            }
          ],
          "text" : "Device is not regulated"
        }
      ]
    }
  ]
}