Personal Health Device Implementation Guide
1.1.0 - STU 1.1 International flag

This page is part of the Personal Health Device FHIR IG (v1.1.0: STU 1) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions

: Example of PHD Device - TTL Representation

Raw ttl | Download


@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

 a fhir:Device ;
  fhir:nodeRole fhir:treeRoot ;
  fhir:id [ fhir:v "phd-74E8FFFEFF051C00.001C05FFE874"] ; # 
  fhir:meta [
    ( fhir:profile [
fhir:v "http://hl7.org/fhir/uv/phd/StructureDefinition/PhdDevice"^^xsd:anyURI ;
fhir:link <http://hl7.org/fhir/uv/phd/StructureDefinition/PhdDevice>     ] )
  ] ; # 
  fhir:text [
fhir:status [ fhir:v "generated" ] ;
fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: Device phd-74E8FFFEFF051C00.001C05FFE874</b></p><a name=\"phd-74E8FFFEFF051C00.001C05FFE874\"> </a><a name=\"hcphd-74E8FFFEFF051C00.001C05FFE874\"> </a><a name=\"phd-74E8FFFEFF051C00.001C05FFE874-en-US\"> </a><p><b>identifier</b>: IEEE 11073 System Identifier/74-E8-FF-FE-FF-05-1C-00, Bluetooth MAC address/00-1C-05-FF-E8-74</p><p><b>manufacturer</b>: Nonin_Medical_Inc.</p><p><b>serialNumber</b>: 501900083</p><p><b>modelNumber</b>: Model 3230</p><p><b>type</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 65573}\">MDC_MOC_VMS_MDS_SIMP</span></p><h3>Specializations</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>SystemType</b></td><td><b>Version</b></td></tr><tr><td style=\"display: none\">*</td><td><span title=\"Codes:{urn:iso:std:iso:11073:10101 528388}\">MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter</span></td><td>1</td></tr></table><blockquote><p><b>version</b></p><p><b>type</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 531976}\">MDC_ID_PROD_SPEC_FW: Firmware revision</span></p><p><b>value</b>: r2.1</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 531975}\">MDC_ID_PROD_SPEC_SW: Software revision</span></p><p><b>value</b>: r1.5 9.7</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 531974}\">MDC_ID_PROD_SPEC_HW: Hardware revision</span></p><p><b>value</b>: r1.0</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 532352}\">MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version</span></p><p><b>value</b>: 6.0</p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 532353}\">MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: certified device list as transport-specialization combo</span></p><p><b>valueCode</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD 32772}\">BTLE Pulse Oximeter certified</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 532354.0}\">regulation-status</span></p><p><b>valueCode</b>: <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 N}\">Device is Regulated</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 68220}\">MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol</span></p><p><b>valueCode</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 532224}\">MDC_TIME_SYNC_NONE:</span></p></blockquote></div>"
  ] ; # 
  fhir:identifier ( [
fhir:type [
      ( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers"^^xsd:anyURI ] ;
fhir:code [ fhir:v "SYSID" ]       ] )     ] ;
fhir:system [ fhir:v "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"^^xsd:anyURI ] ;
fhir:value [ fhir:v "74-E8-FF-FE-FF-05-1C-00" ]
  ] [
fhir:type [
      ( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers"^^xsd:anyURI ] ;
fhir:code [ fhir:v "BTMAC" ]       ] )     ] ;
fhir:system [ fhir:v "http://hl7.org/fhir/sid/eui-48/bluetooth"^^xsd:anyURI ] ;
fhir:value [ fhir:v "00-1C-05-FF-E8-74" ]
  ] ) ; # 
  fhir:manufacturer [ fhir:v "Nonin_Medical_Inc."] ; # 
  fhir:serialNumber [ fhir:v "501900083"] ; # 
  fhir:modelNumber [ fhir:v "Model 3230"] ; # 
  fhir:type [
    ( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "65573" ]     ] ) ;
fhir:text [ fhir:v "MDC_MOC_VMS_MDS_SIMP" ]
  ] ; # 
  fhir:specialization ( [
fhir:systemType [
      ( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "528388" ]       ] ) ;
fhir:text [ fhir:v "MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter" ]     ] ;
fhir:version [ fhir:v "1" ]
  ] ) ; # 
  fhir:version ( [
fhir:type [
      ( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "531976" ]       ] ) ;
fhir:text [ fhir:v "MDC_ID_PROD_SPEC_FW: Firmware revision" ]     ] ;
fhir:value [ fhir:v "r2.1" ]
  ] [
fhir:type [
      ( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "531975" ]       ] ) ;
fhir:text [ fhir:v "MDC_ID_PROD_SPEC_SW: Software revision" ]     ] ;
fhir:value [ fhir:v "r1.5 9.7" ]
  ] [
fhir:type [
      ( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "531974" ]       ] ) ;
fhir:text [ fhir:v "MDC_ID_PROD_SPEC_HW: Hardware revision" ]     ] ;
fhir:value [ fhir:v "r1.0" ]
  ] [
fhir:type [
      ( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "532352" ]       ] ) ;
fhir:text [ fhir:v "MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version" ]     ] ;
fhir:value [ fhir:v "6.0" ]
  ] ) ; # 
  fhir:property ( [
fhir:type [
      ( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "532353" ]       ] ) ;
fhir:text [ fhir:v "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: certified device list as transport-specialization combo" ]     ] ;
    ( fhir:valueCode [
      ( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD"^^xsd:anyURI ] ;
fhir:code [ fhir:v "32772" ]       ] )     ] )
  ] [
fhir:type [
      ( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"^^xsd:anyURI ] ;
fhir:code [ fhir:v "532354.0" ]       ] ) ;
fhir:text [ fhir:v "regulation-status" ]     ] ;
    ( fhir:valueCode [
      ( fhir:coding [
fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/v2-0136"^^xsd:anyURI ] ;
fhir:code [ fhir:v "N" ]       ] ) ;
fhir:text [ fhir:v "Device is Regulated" ]     ] )
  ] [
fhir:type [
      ( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "68220" ]       ] ) ;
fhir:text [ fhir:v "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol" ]     ] ;
    ( fhir:valueCode [
      ( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "532224" ]       ] ) ;
fhir:text [ fhir:v "MDC_TIME_SYNC_NONE:" ]     ] )
  ] ) . #