This page is part of the Personal Health Device FHIR IG (v1.1.0: STU 1) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version. For a full list of available versions, see the Directory of published versions
@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
# - resource -------------------------------------------------------------------
a fhir:Device ;
fhir:nodeRole fhir:treeRoot ;
fhir:id [ fhir:v "phg-ecde3d4e58532d31.000000000000"] ; #
fhir:meta [
( fhir:profile [
fhir:v "http://hl7.org/fhir/uv/phd/StructureDefinition/PhgDevice"^^xsd:anyURI ;
fhir:link <http://hl7.org/fhir/uv/phd/StructureDefinition/PhgDevice> ] )
] ; #
fhir:text [
fhir:status [ fhir:v "generated" ] ;
fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: Device phg-ecde3d4e58532d31.000000000000</b></p><a name=\"phg-ecde3d4e58532d31.000000000000\"> </a><a name=\"hcphg-ecde3d4e58532d31.000000000000\"> </a><a name=\"phg-ecde3d4e58532d31.000000000000-en-US\"> </a><p><b>identifier</b>: IEEE 11073 System Identifier/ec-de-3d-4e-58-53-2d-31, Bluetooth MAC address/3d-4e-58-53-2d-31, Ethernet MAC address/3d-4e-58-53-2d-35</p><p><b>type</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 531981}\">MDC_MOC_VMS_MDS_AHD</span></p><h3>Versions</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Type</b></td><td><b>Value</b></td></tr><tr><td style=\"display: none\">*</td><td><span title=\"Codes:{urn:iso:std:iso:11073:10101 532352}\">MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version</span></td><td>5.0</td></tr></table><blockquote><p><b>property</b></p><p><b>type</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 68220}\">MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol</span></p><p><b>valueCode</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 532226}\">MDC_TIME_SYNC_NTPV4:</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 532353}\">MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: certified device list as transport-specialization combo</span></p><p><b>valueCode</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD 4}\">Pulse Oximeter certified</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 532355}\">MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: certified Upload classes</span></p><p><b>valueCode</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS 0}\">observation-upload-soap</span>, <span title=\"Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS 3}\">observation-upload-hdata</span>, <span title=\"Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS 7}\">observation-upload-fhir</span>, <span title=\"Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS 2}\">capabilities</span>, <span title=\"Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS 6}\">aps</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 532354.0}\">regulation-status</span></p><p><b>valueCode</b>: <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}\">Device is not regulated</span></p></blockquote></div>"
] ; #
fhir:identifier ( [
fhir:type [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers"^^xsd:anyURI ] ;
fhir:code [ fhir:v "SYSID" ] ] ) ] ;
fhir:system [ fhir:v "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"^^xsd:anyURI ] ;
fhir:value [ fhir:v "ec-de-3d-4e-58-53-2d-31" ]
] [
fhir:type [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers"^^xsd:anyURI ] ;
fhir:code [ fhir:v "BTMAC" ] ] ) ] ;
fhir:system [ fhir:v "http://hl7.org/fhir/sid/eui-48/bluetooth"^^xsd:anyURI ] ;
fhir:value [ fhir:v "3d-4e-58-53-2d-31" ]
] [
fhir:type [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers"^^xsd:anyURI ] ;
fhir:code [ fhir:v "ETHMAC" ] ] ) ] ;
fhir:system [ fhir:v "http://hl7.org/fhir/sid/eui-48/ethernet"^^xsd:anyURI ] ;
fhir:value [ fhir:v "3d-4e-58-53-2d-35" ]
] ) ; #
fhir:type [
( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "531981" ] ] ) ;
fhir:text [ fhir:v "MDC_MOC_VMS_MDS_AHD" ]
] ; #
fhir:version ( [
fhir:type [
( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "532352" ] ] ) ;
fhir:text [ fhir:v "MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version" ] ] ;
fhir:value [ fhir:v "5.0" ]
] ) ; #
fhir:property ( [
fhir:type [
( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "68220" ] ] ) ;
fhir:text [ fhir:v "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol" ] ] ;
( fhir:valueCode [
( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "532226" ] ] ) ;
fhir:text [ fhir:v "MDC_TIME_SYNC_NTPV4:" ] ] )
] [
fhir:type [
( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "532353" ] ] ) ;
fhir:text [ fhir:v "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: certified device list as transport-specialization combo" ] ] ;
( fhir:valueCode [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD"^^xsd:anyURI ] ;
fhir:code [ fhir:v "4" ] ] ) ] )
] [
fhir:type [
( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "532355" ] ] ) ;
fhir:text [ fhir:v "MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: certified Upload classes" ] ] ;
( fhir:valueCode [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS"^^xsd:anyURI ] ;
fhir:code [ fhir:v "0" ] ] ) ] [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS"^^xsd:anyURI ] ;
fhir:code [ fhir:v "3" ] ] ) ] [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS"^^xsd:anyURI ] ;
fhir:code [ fhir:v "7" ] ] ) ] [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS"^^xsd:anyURI ] ;
fhir:code [ fhir:v "2" ] ] ) ] [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS"^^xsd:anyURI ] ;
fhir:code [ fhir:v "6" ] ] ) ] )
] [
fhir:type [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"^^xsd:anyURI ] ;
fhir:code [ fhir:v "532354.0" ] ] ) ;
fhir:text [ fhir:v "regulation-status" ] ] ;
( fhir:valueCode [
( fhir:coding [
fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/v2-0136"^^xsd:anyURI ] ;
fhir:code [ fhir:v "Y" ] ] ) ;
fhir:text [ fhir:v "Device is not regulated" ] ] )
] ) . #
IG © 2016+ HL7 International / Health Care Devices. Package hl7.fhir.uv.phd#1.1.0 based on FHIR 4.0.1. Generated 2024-10-18
Links: Table of Contents |
QA Report
| Version History |
|
Propose a change