This page is part of the Personal Health Device FHIR IG (v2.0.0-ballot2: STU 2 Ballot) based on FHIR (HL7® FHIR® Standard) R4. This version is a pre-release. The current official version is 1.1.0. For a full list of available versions, see the Directory of published versions
Page standards status: Informative |
This example is an observation coming from a glucose meter and explains why a measurement failed. There is no such measurement type defined in the Glucose specialization so this manufacturer used a private attribute.
Note there is no logical id needed in this resource when this resource is being uploaded to the server in a create operation. The server will create the logical id and return it to the sender in the response. The logical id in the example is present due to limitations of the publishing process.
Profile: PhdStringObservation
Observation Gateway Device: Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address,Ethernet MAC address; type = MDC_MOC_VMS_MDS_AHD
Coincident Timestamp Reference: Observation MDC_ATTR_TIME_ABS
status: Final
category: PHD generated Observation
code: Private MDC code: MDCX_GLU_TEST_STRIP_FAILURE_REASON
subject: Sisansarah Lorianthah Piggy (no stated gender), DoB Unknown ( Medical record number)
effective: 2018-08-02 03:25:24-0400
value: Test Strip Buckled