Validation Results for PhdImplementationGuide
Generated Fri Aug 16 03:18:59 UTC 2024, FHIR version 4.3.0 for hl7.fhir.uv.phd#2.0.0-ballot (canonical = http://hl7.org/fhir/uv/phd (history)). See Full QA Report
Quality Checks |
Publisher Version: | IG Publisher Version: v1.6.20 |
Publication Code: | phd . PackageId = hl7.fhir.uv.phd, Canonical = http://hl7.org/fhir/uv/phd |
Realm Check for UV: | |
Publication Request: |
package-id | hl7.fhir.uv.phd |
version | 2.0.0-ballot |
path | http://hl7.org/fhir/uv/phd/2024Sep |
Pub-Mode | working release |
status | ballot |
Release-Label | STU2 Ballot |
sequence | STU 2 |
desc | This version is a working draft to be based on IEEE 11073-10206 - ACOM with Bluetooth GHS support. |
changes | input/pagecontent/changes.md |
Proposed path for this publication should usually be the canonical with the version or sequence appended and then some kind of label (typically '-snapshot') |
Supressed Messages: | 11 Suppressed Issues
|
Dependency Checks: | Package | Version | FHIR | Canonical | Web Base | Comment |
---|
hl7.fhir.uv.phd | 2.0.0-ballot | R4B | http://hl7.org/fhir/uv/phd | | |
hl7.terminology.r4 | 6.0.2 M | R4 | http://terminology.hl7.org | http://terminology.hl7.org/6.0.2 | FHIR Version Mismatch |
hl7.fhir.uv.extensions.r4 | 5.1.0 M | R4 | http://hl7.org/fhir/extensions | http://hl7.org/fhir/extensions/5.1.0 | FHIR Version Mismatch |
hl7.fhir.uv.pocd | 0.3.0 I | R4 | http://hl7.org/fhir/uv/pocd | http://hl7.org/fhir/uv/pocd/2021Sep | FHIR Version Mismatch |
Templates: hl7.fhir.template#current -> hl7.base.template#current -> fhir.base.template#current. Tools: 0.1.0 |
Dependent IGs: | no references |
Global Profiles: | (none declared) |
Terminology Server(s): | http://tx.fhir.org/r4 (details) |
HTA Analysis: | All OK |
R5 Dependencies: | (none) |
Draft Dependencies: |
-
hl7.fhir.r4b.core#4.3.0: GuideParameterCode
(15 uses), Shareable CodeSystem
(7 uses), CommonTags
(7 uses), CommonLanguages
(12 uses), Organization
(35 uses), CarePlan
(8 uses), DeviceRequest
(8 uses), ImmunizationRecommendation
(8 uses), MedicationRequest
(8 uses), NutritionOrder
(8 uses), ServiceRequest
(8 uses), MedicationAdministration
(8 uses), MedicationDispense
(8 uses), MedicationStatement
(8 uses), Procedure
(16 uses), Immunization
(8 uses), ImagingStudy
(16 uses), ObservationStatus
(8 uses), ObservationCategoryCodes
(18 uses), LOINCCodes
(16 uses), Group
(8 uses), Device
(22 uses), Location
(10 uses), Practitioner
(17 uses), Medication
(8 uses), Substance
(8 uses), Encounter
(8 uses), PractitionerRole
(9 uses), CareTeam
(8 uses), RelatedPerson
(9 uses), SNOMEDCTBodyStructures
(8 uses), ObservationMethods
(8 uses), Specimen
(8 uses), DeviceMetric
(8 uses), ObservationReferenceRangeMeaningCodes
(9 uses), ObservationReferenceRangeAppliesToCodes
(9 uses), QuestionnaireResponse
(16 uses), MolecularSequence
(16 uses), DocumentReference
(8 uses), Media
(8 uses), DeviceDefinition
(2 uses), UDIEntryType
(2 uses), FHIRDeviceStatus
(2 uses), FHIRDeviceStatusReason
(2 uses), DeviceNameType
(2 uses), DeviceType
(2 uses), regex
(2 uses), Shareable ValueSet
(11 uses)
-
hl7.fhir.uv.pocd#0.3.0: PoCDImplementationGuide
(1 uses), MeasurementStatus
(10 uses)
-
hl7.fhir.uv.tools#0.2.0: ResourceSortExt
(48 uses)
|
Modifier Extensions: | (none) |
Previous Version Comparison: | Comparison with version 1.0.0 |
IPA Comparison: | n/a |
IPS Comparison: | n/a |
Summary: | errors = 0, warn = 1, info = 0, broken links = 0 |
n/a Show Validation Information
| warning | The jira specification file appears to be out of date with the versions, artifacts and pages currently defined in the IG. A proposed revised file to be reviewed and, if appropriate, submitted as a pull request against the XML folder in https://github.com/HL7/JIRA-Spec-Artifacts. To see the differences, perform a file compare on 'template/jira-current.xml' (a normalized view of what is in Github) and 'template/jira-new.xml' (reflects current IG content) |
Suppressed Messages (Warnings, hints, broken links)
All example observation in this IG are suppossed to be device generated with often an unknown performer. There is text in the IG to explain this. The affected example observations / bundles are: bits-observation.json, bundle-continuousnonin.json, bundle-example-1.json, coin-20181119174911.json, coin-20181119202022.json, coin-example-1.json, coin-example-timefault.json, glucose-1.0.0.4.json, numeric-observation-not-a-number.json, numeric-spotnumeric.json, stringenum-1234.json
- Best Practice Recommendation: In general, all observations should have a performer (15 uses)
The ISO/IEEE 11073 Codesystem is not draft - fixed by Grahame, but needs time before this warning goes away... https://chat.fhir.org/#narrow/stream/179166-implementers/topic/Why.20is.20the.20ISO.2FIEEE.2011073.20Codesystem.20seen.20as.20draft.3F
- Reference to draft CodeSystem urn:iso:std:iso:11073:10101|2023-04-26 (0 uses)
These code systems are PHD specific
- Most code systems defined in HL7 IGs will need to move to THO later during the process. Consider giving this code system a THO URL now (See https://confluence.hl7.org/display/TSMG/Terminology+Play+Book, and/or talk to TSMG) (7 uses)
This is a recent code for a spirometer device type. Created a pull request on the codes in https://github.com/FHIR/packages/pulls
- The code '528413' is not valid in the system urn:iso:std:iso:11073:10101 (Unknown code '528413' in the CodeSystem 'urn:iso:std:iso:11073:10101' version '2023-04-26') (1 uses)
This warning is generated for a coincident timestamp observation that is not a vital signs observation, but referenced in a derivedFrom element in another observation that is a vital sign. This will be fixed by using an extension instead in the next version of the IG. See https://jira.hl7.org/browse/FHIR-46586.
- Details for urn:uuid:323f0631-6bca-47aa-8adf-69fdaf910108 matching against profile http://hl7.org/fhir/StructureDefinition/vitalsigns|4.3.0 (2 uses)
This warning is generated when different categories are required in resources that comply with different profiles like vitals-signs and phd-observations:
- None of the codings provided are in the value set 'Observation Category Codes' (http://hl7.org/fhir/ValueSet/observation-category|4.3.0), and a coding is recommended to come from this value set (codes = http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories#phd-observation) (2 uses)
When a vital signs observation has a derivedFrom reference to a timestamp observation this is also checked against vital signs, leading to these warnings.
- This element does not match any known slice Defined in the profile http://hl7.org/fhir/uv/phd/StructureDefinition/PhdCompoundNumericObservation|2.0.0-ballot (this may not be a problem, but you should check that it's not intended to match a slice) (3 uses)
- This element does not match any known slice defined in the profile http://hl7.org/fhir/StructureDefinition/bp|4.3.0 (this may not be a problem, but you should check that it's not intended to match a slice) (4 uses)
- This element does not match any known slice defined in the profile http://hl7.org/fhir/StructureDefinition/heartrate|4.3.0 (this may not be a problem, but you should check that it's not intended to match a slice) (2 uses)
- This element does not match any known slice defined in the profile http://hl7.org/fhir/StructureDefinition/oxygensat|4.3.0 (this may not be a problem, but you should check that it's not intended to match a slice) (1 uses)
partition is a known IEEE 11073-10101 concept - discussion on Zulip how to fix this: https://chat.fhir.org/#narrow/stream/179166-implementers/topic/Why.20is.20the.20ISO.2FIEEE.2011073.20Codesystem.20seen.20as.20draft.3F/near/456526001
- The property 'partition' is not known for the system 'urn:iso:std:iso:11073:10101', so may not be understood by the terminology ecosystem. Known properties for this system: concept,code,status,inactive,effectiveDate,deprecationDate,retirementDate,notSelectable,synonym,comment,itemWeight (2 uses)
Errors sorted by type