This is the set of resources that conform to either of the profiles PhgDevice (http://hl7.org/fhir/uv/phd/StructureDefinition/PhgDevice) and PhgDevice (http://hl7.org/fhir/uv/phd/StructureDefinition/PhgDevice). E.g. what you have to deal with if you get resources conforming to one of them
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | 0..* | Item used in healthcare dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated dom-5: If a resource is contained in another resource, it SHALL NOT have a security label dom-6: A resource should have narrative for robust management | ||
meta | Σ | 0..1 | Meta | Metadata about the resource ele-1: All FHIR elements must have a @value or children |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
versionId | Σ | 0..1 | id | Version specific identifier ele-1: All FHIR elements must have a @value or children |
lastUpdated | Σ | 0..1 | instant | When the resource version last changed ele-1: All FHIR elements must have a @value or children |
source | Σ | 0..1 | uri | Identifies where the resource comes from ele-1: All FHIR elements must have a @value or children |
profile | Σ | 1..* | canonical(StructureDefinition) | Profiles this resource claims to conform to Slice: Unordered, Open by value:value ele-1: All FHIR elements must have a @value or children |
security | Σ | 0..* | Coding | Security Labels applied to this resource Binding: ?? (extensible): Security Labels from the Healthcare Privacy and Security Classification System. ele-1: All FHIR elements must have a @value or children |
tag | Σ | 0..* | Coding | Tags applied to this resource Binding: ?? (example): Codes that represent various types of tags, commonly workflow-related; e.g. "Needs review by Dr. Jones". ele-1: All FHIR elements must have a @value or children |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created ele-1: All FHIR elements must have a @value or children |
language | 0..1 | code | Language of the resource content Binding: ?? (preferred): left: A human language.; right: IETF language tag ele-1: All FHIR elements must have a @value or children | |
text | 0..1 | Narrative | Text summary of the resource, for human interpretation ele-1: All FHIR elements must have a @value or children | |
contained | 0..* | Resource | Contained, inline Resources | |
extension | 0..* | Extension | Additional content defined by implementations ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
identifier | 1..* | Identifier | Information that uniquely describes the personal health device ele-1: All FHIR elements must have a @value or children | |
definition | 0..1 | Reference(DeviceDefinition) | The reference to the definition for the device ele-1: All FHIR elements must have a @value or children | |
udiCarrier | Σ | 0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string ele-1: All FHIR elements must have a @value or children |
extension | 0..* | Extension | Additional content defined by implementations ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
deviceIdentifier | Σ | 0..1 | string | Mandatory fixed portion of UDI ele-1: All FHIR elements must have a @value or children |
issuer | 0..1 | uri | UDI Issuing Organization ele-1: All FHIR elements must have a @value or children | |
jurisdiction | 0..1 | uri | Regional UDI authority ele-1: All FHIR elements must have a @value or children | |
carrierAIDC | Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String ele-1: All FHIR elements must have a @value or children |
carrierHRF | Σ | 0..1 | string | UDI Human Readable Barcode String ele-1: All FHIR elements must have a @value or children |
entryType | 0..1 | code | barcode | rfid | manual + Binding: ?? (required): Codes to identify how UDI data was entered. ele-1: All FHIR elements must have a @value or children | |
status | ?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: ?? (required): The availability status of the device. ele-1: All FHIR elements must have a @value or children |
statusReason | 0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: ?? (extensible): The availability status reason of the device. ele-1: All FHIR elements must have a @value or children | |
distinctIdentifier | 0..1 | string | The distinct identification string ele-1: All FHIR elements must have a @value or children | |
manufacturer | 0..1 | string | Manufacturer name ele-1: All FHIR elements must have a @value or children | |
manufactureDate | 0..1 | dateTime | Date when the device was made ele-1: All FHIR elements must have a @value or children | |
expirationDate | 0..1 | dateTime | Date and time of expiry of this device (if applicable) ele-1: All FHIR elements must have a @value or children | |
lotNumber | 0..1 | string | Lot number of manufacture ele-1: All FHIR elements must have a @value or children | |
serialNumber | 0..1 | string | Serial number ele-1: All FHIR elements must have a @value or children | |
deviceName | 0..* | BackboneElement | The name of the device as given by the manufacturer ele-1: All FHIR elements must have a @value or children | |
extension | 0..* | Extension | Additional content defined by implementations ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
name | 1..1 | string | left: The name of the device; right: The name that identifies the device ele-1: All FHIR elements must have a @value or children | |
type | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: ?? (required): The type of name the device is referred by. ele-1: All FHIR elements must have a @value or children | |
modelNumber | 0..1 | string | Model number ele-1: All FHIR elements must have a @value or children | |
partNumber | 0..1 | string | left: The part number of the device; right: The part number or catalog number of the device ele-1: All FHIR elements must have a @value or children | |
type | 1..1 | CodeableConcept | Indicates the device is a PHG. Binding: ?? (example): Codes to identify medical devices. ele-1: All FHIR elements must have a @value or children | |
extension | 0..* | Extension | Additional content defined by implementations ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
coding | Σ | 1..* | Coding | Code defined by a terminology system ele-1: All FHIR elements must have a @value or children |
text | Σ | 0..1 | string | Plain text representation of the concept ele-1: All FHIR elements must have a @value or children |
specialization | 0..* | BackboneElement | This element contains an entry for each supported specialization or a generic representation ele-1: All FHIR elements must have a @value or children | |
extension | 0..* | Extension | Additional content defined by implementations ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
systemType | 1..1 | CodeableConcept | The specialization standard supported by the PHG. ele-1: All FHIR elements must have a @value or children | |
extension | 0..* | Extension | Additional content defined by implementations ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
coding | Σ | 1..* | Coding | Code defined by a terminology system ele-1: All FHIR elements must have a @value or children |
text | Σ | 0..1 | string | Plain text representation of the concept ele-1: All FHIR elements must have a @value or children |
version | 0..1 | string | The version of the specialization standard supported by the PHG ele-1: All FHIR elements must have a @value or children | |
version | 1..* | BackboneElement | A firmware, hardware, software, internal protocol may be reported for a PHG. A Continua version shall be reported. ele-1: All FHIR elements must have a @value or children | |
extension | 0..* | Extension | Additional content defined by implementations ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
type | 1..1 | CodeableConcept | left: The type of the device version; right: The type of the device version, e.g. manufacturer, approved, internal ele-1: All FHIR elements must have a @value or children | |
extension | 0..* | Extension | Additional content defined by implementations ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
coding | Σ | 1..* | Coding | Code defined by a terminology system ele-1: All FHIR elements must have a @value or children |
text | Σ | 0..1 | string | Plain text representation of the concept ele-1: All FHIR elements must have a @value or children |
component | 0..1 | Identifier | A single component of the device version ele-1: All FHIR elements must have a @value or children | |
value | 1..1 | string | The version ele-1: All FHIR elements must have a @value or children | |
property | 1..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties ele-1: All FHIR elements must have a @value or children | |
extension | 0..* | Extension | Additional content defined by implementations ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) ele-1: All FHIR elements must have a @value or children | |
valueQuantity | 0..* | Quantity | Property value as a quantity ele-1: All FHIR elements must have a @value or children | |
valueCode | 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) ele-1: All FHIR elements must have a @value or children | |
patient | 0..1 | Reference(Patient) | Patient to whom Device is affixed ele-1: All FHIR elements must have a @value or children | |
owner | 0..1 | Reference(Organization) | Organization responsible for device ele-1: All FHIR elements must have a @value or children | |
contact | 0..* | ContactPoint | Details for human/organization for support ele-1: All FHIR elements must have a @value or children | |
location | 0..1 | Reference(Location) | Where the device is found ele-1: All FHIR elements must have a @value or children | |
url | 0..1 | uri | Network address to contact device ele-1: All FHIR elements must have a @value or children | |
note | 0..* | Annotation | Device notes and comments ele-1: All FHIR elements must have a @value or children | |
safety | Σ | 0..* | CodeableConcept | Safety Characteristics of Device ele-1: All FHIR elements must have a @value or children |
parent | 0..1 | Reference(Device) | left: The parent device; right: The device that this device is attached to or is part of ele-1: All FHIR elements must have a @value or children | |
Documentation for this format |