Personal Health Device Implementation Guide
2.0.0-ballot - STU2 Ballot International flag

This page is part of the Personal Health Device FHIR IG (v2.0.0-ballot: STU 2 Ballot 1) based on FHIR (HL7® FHIR® Standard) v4.3.0. The current version which supersedes this version is 1.0.0. For a full list of available versions, see the Directory of published versions

: Example of an Rtsa. - JSON Representation

Raw json | Download


{
  "resourceType" : "Observation",
  "id" : "rtsa-1234",
  "meta" : {
    "profile" : [
      🔗 "http://hl7.org/fhir/uv/phd/StructureDefinition/PhdRtsaObservation"
    ]
  },
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: Observation rtsa-1234</b></p><a name=\"rtsa-1234\"> </a><a name=\"hcrtsa-1234\"> </a><a name=\"rtsa-1234-en-US\"> </a><p><b>status</b>: Final</p><p><b>category</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}\">PHD generated Observation</span></p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 150452}\">MDC_PULS_OXIM_PLETH: Pleth Wave</span></p><p><b>subject</b>: <a href=\"Patient-patientExample-1.html\">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-08-02 02:25:24-0400</p><p><b>performer</b>: <a href=\"Patient-patientExample-1.html\">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>value</b>: Origin: -3.4 1 , Factor: 3.0 , Dimensions: 1 , Data: 123 110 97 99 112 118 </p><p><b>device</b>: <a href=\"Device-phd-00601900010E9234.F45EABA80832.html\">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Diabetes Care; serialNumber = 20130200002A; modelNumber = Gluc-23; type = MDC_MOC_VMS_MDS_SIMP</a></p><p><b>derivedFrom</b>: <a href=\"Observation-coin-example-1.html\">Observation MDC_ATTR_TIME_ABS</a></p></div>"
  },
  "extension" : [
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice",
      "valueReference" : {
        🔗 "reference" : "Device/phg-ecde3d4e58532d31.000000000000"
      }
    }
  ],
  "status" : "final",
  "category" : [
    {
      "coding" : [
        {
          "system" : "http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories",
          "code" : "phd-observation"
        }
      ]
    }
  ],
  "code" : {
    "coding" : [
      {
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "150452"
      }
    ],
    "text" : "MDC_PULS_OXIM_PLETH: Pleth Wave"
  },
  "subject" : {
    🔗 "reference" : "Patient/patientExample-1"
  },
  "effectiveDateTime" : "2018-08-02T02:25:24-04:00",
  "performer" : [
    {
      🔗 "reference" : "Patient/patientExample-1"
    }
  ],
  "valueSampledData" : {
    "origin" : {
      "value" : -3.4,
      "system" : "http://unitsofmeasure.org",
      "code" : "1"
    },
    "period" : 2.000,
    "factor" : 3.0,
    "dimensions" : 1,
    "data" : "123 110 97 99 112 118"
  },
  "device" : {
    🔗 "reference" : "Device/phd-00601900010E9234.F45EABA80832"
  },
  "derivedFrom" : [
    {
      🔗 "reference" : "Observation/coin-example-1"
    }
  ]
}