This page is part of the Personal Health Device FHIR IG (v2.0.0-ballot: STU 2 Ballot 1) based on FHIR (HL7® FHIR® Standard) v4.3.0. The current version which supersedes this version is 1.0.0. For a full list of available versions, see the Directory of published versions
{
"resourceType" : "Device",
"id" : "phd-74E8FFFEFF051C00.001C05FFE874",
"meta" : {
"profile" : [
🔗 "http://hl7.org/fhir/uv/phd/StructureDefinition/PhdDevice"
]
},
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: Device phd-74E8FFFEFF051C00.001C05FFE874</b></p><a name=\"phd-74E8FFFEFF051C00.001C05FFE874\"> </a><a name=\"hcphd-74E8FFFEFF051C00.001C05FFE874\"> </a><a name=\"phd-74E8FFFEFF051C00.001C05FFE874-en-US\"> </a><p><b>identifier</b>: IEEE 11073 System Identifier/74-E8-FF-FE-FF-05-1C-00, Bluetooth MAC address/00-1C-05-FF-E8-74</p><p><b>manufacturer</b>: Nonin_Medical_Inc.</p><p><b>serialNumber</b>: 501900083</p><p><b>modelNumber</b>: Model 3230</p><p><b>type</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 65573}\">MDC_MOC_VMS_MDS_SIMP</span></p><h3>Specializations</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>SystemType</b></td><td><b>Version</b></td></tr><tr><td style=\"display: none\">*</td><td><span title=\"Codes:{urn:iso:std:iso:11073:10101 528388}\">MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter</span></td><td>1</td></tr></table><blockquote><p><b>version</b></p><p><b>type</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 531976}\">MDC_ID_PROD_SPEC_FW: Firmware revision</span></p><p><b>value</b>: r2.1</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 531975}\">MDC_ID_PROD_SPEC_SW: Software revision</span></p><p><b>value</b>: r1.5 9.7</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 531974}\">MDC_ID_PROD_SPEC_HW: Hardware revision</span></p><p><b>value</b>: r1.0</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 532352}\">MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version</span></p><p><b>value</b>: 6.0</p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 532353}\">MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: certified device list as transport-specialization combo</span></p><p><b>valueCode</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD 32772}\">BTLE Pulse Oximeter certified</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 532354.0}\">regulation-status</span></p><p><b>valueCode</b>: <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 N}\">Device is Regulated</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 68220}\">MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol</span></p><p><b>valueCode</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 532224}\">MDC_TIME_SYNC_NONE:</span></p></blockquote></div>"
},
"identifier" : [
{
"type" : {
"coding" : [
{
"system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers",
"code" : "SYSID"
}
]
},
"system" : "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680",
"value" : "74-E8-FF-FE-FF-05-1C-00"
},
{
"type" : {
"coding" : [
{
"system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers",
"code" : "BTMAC"
}
]
},
"system" : "http://hl7.org/fhir/sid/eui-48/bluetooth",
"value" : "00-1C-05-FF-E8-74"
}
],
"manufacturer" : "Nonin_Medical_Inc.",
"serialNumber" : "501900083",
"modelNumber" : "Model 3230",
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "65573"
}
],
"text" : "MDC_MOC_VMS_MDS_SIMP"
},
"specialization" : [
{
"systemType" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "528388"
}
],
"text" : "MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter"
},
"version" : "1"
}
],
"version" : [
{
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "531976"
}
],
"text" : "MDC_ID_PROD_SPEC_FW: Firmware revision"
},
"value" : "r2.1"
},
{
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "531975"
}
],
"text" : "MDC_ID_PROD_SPEC_SW: Software revision"
},
"value" : "r1.5 9.7"
},
{
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "531974"
}
],
"text" : "MDC_ID_PROD_SPEC_HW: Hardware revision"
},
"value" : "r1.0"
},
{
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "532352"
}
],
"text" : "MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version"
},
"value" : "6.0"
}
],
"property" : [
{
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "532353"
}
],
"text" : "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: certified device list as transport-specialization combo"
},
"valueCode" : [
{
"coding" : [
{
"system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD",
"code" : "32772"
}
]
}
]
},
{
"type" : {
"coding" : [
{
"system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7",
"code" : "532354.0"
}
],
"text" : "regulation-status"
},
"valueCode" : [
{
"coding" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/v2-0136",
"code" : "N"
}
],
"text" : "Device is Regulated"
}
]
},
{
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "68220"
}
],
"text" : "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"
},
"valueCode" : [
{
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "532224"
}
],
"text" : "MDC_TIME_SYNC_NONE:"
}
]
}
]
}