Personal Health Device Implementation Guide
2.0.0-ballot - STU2 Ballot International flag

This page is part of the Personal Health Device FHIR IG (v2.0.0-ballot: STU 2 Ballot 1) based on FHIR (HL7® FHIR® Standard) v4.3.0. The current version which supersedes this version is 1.0.0. For a full list of available versions, see the Directory of published versions

: Example Bundled upload - XML Representation

Raw xml | Download



<Bundle xmlns="http://hl7.org/fhir">
  <id value="bundle-continuousnonin"/>
  <type value="transaction"/>
  <entry>
    <fullUrl value="urn:oid:1.0.0.1"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 67996}">MDC_ATTR_VAL_BATT_CHARGE</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:36-0500</p><p><b>value</b>: 100 %<span style="background: LightGoldenRodYellow"> (Details: UCUM  code% = '%')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="67996"/>
          </coding>
          <text value="MDC_ATTR_VAL_BATT_CHARGE"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:36-05:00"/>
        <valueQuantity>
          <value value="100"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="%"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.2"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}">Vital Signs</span>, <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150456}, {http://loinc.org 59408-5}">MDC_PULS_OXIM_SAT_O2</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:37-0500</p><p><b>value</b>: 99.0 %<span style="background: LightGoldenRodYellow"> (Details: UCUM  code% = '%')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://terminology.hl7.org/CodeSystem/observation-category"/>
            <code value="vital-signs"/>
          </coding>
          <text value="Vital Signs"/>
        </category>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150456"/>
          </coding>
          <coding>
            <system value="http://loinc.org"/>
            <code value="59408-5"/>
          </coding>
          <text value="MDC_PULS_OXIM_SAT_O2"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:37-05:00"/>
        <valueQuantity>
          <value value="99.0"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="%"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.3"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}">Vital Signs</span>, <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 149530}, {http://loinc.org 8867-4}">MDC_PULS_OXIM_PULS_RATE</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:37-0500</p><p><b>value</b>: 53.0 {beat}/min<span style="background: LightGoldenRodYellow"> (Details: UCUM  code{beat}/min = '{beat}/min')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://terminology.hl7.org/CodeSystem/observation-category"/>
            <code value="vital-signs"/>
          </coding>
          <text value="Vital Signs"/>
        </category>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="149530"/>
          </coding>
          <coding>
            <system value="http://loinc.org"/>
            <code value="8867-4"/>
          </coding>
          <text value="MDC_PULS_OXIM_PULS_RATE"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:37-05:00"/>
        <valueQuantity>
          <value value="53.0"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="{beat}/min"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.4"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150320}">MDC_SAT_O2_QUAL</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:37-0500</p><p><b>value</b>: 1.02 %<span style="background: LightGoldenRodYellow"> (Details: UCUM  code% = '%')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150320"/>
          </coding>
          <text value="MDC_SAT_O2_QUAL"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:37-05:00"/>
        <valueQuantity>
          <value value="1.02"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="%"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.5"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}">Vital Signs</span>, <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150456}, {http://loinc.org 59408-5}">MDC_PULS_OXIM_SAT_O2</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:38-0500</p><p><b>value</b>: 100.0 %<span style="background: LightGoldenRodYellow"> (Details: UCUM  code% = '%')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://terminology.hl7.org/CodeSystem/observation-category"/>
            <code value="vital-signs"/>
          </coding>
          <text value="Vital Signs"/>
        </category>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150456"/>
          </coding>
          <coding>
            <system value="http://loinc.org"/>
            <code value="59408-5"/>
          </coding>
          <text value="MDC_PULS_OXIM_SAT_O2"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:38-05:00"/>
        <valueQuantity>
          <value value="100.0"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="%"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.6"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}">Vital Signs</span>, <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 149530}, {http://loinc.org 8867-4}">MDC_PULS_OXIM_PULS_RATE</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:38-0500</p><p><b>value</b>: 54.0 {beat}/min<span style="background: LightGoldenRodYellow"> (Details: UCUM  code{beat}/min = '{beat}/min')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://terminology.hl7.org/CodeSystem/observation-category"/>
            <code value="vital-signs"/>
          </coding>
          <text value="Vital Signs"/>
        </category>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="149530"/>
          </coding>
          <coding>
            <system value="http://loinc.org"/>
            <code value="8867-4"/>
          </coding>
          <text value="MDC_PULS_OXIM_PULS_RATE"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:38-05:00"/>
        <valueQuantity>
          <value value="54.0"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="{beat}/min"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.7"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150320}">MDC_SAT_O2_QUAL</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:38-0500</p><p><b>value</b>: 0.88 %<span style="background: LightGoldenRodYellow"> (Details: UCUM  code% = '%')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150320"/>
          </coding>
          <text value="MDC_SAT_O2_QUAL"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:38-05:00"/>
        <valueQuantity>
          <value value="0.88"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="%"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.8"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdBitsEnumerationObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150604}">MDC_PULS_OXIM_DEV_STATUS</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:39-0500</p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.7}">signal-pulse-questionable</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Questionable pulse detected</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.11}">signal-poor</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Signal is poor</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.12}">signal-inadequate</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Signal is inadequate</span></p></blockquote></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150604"/>
          </coding>
          <text value="MDC_PULS_OXIM_DEV_STATUS"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:39-05:00"/>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.7"/>
            </coding>
            <text value="signal-pulse-questionable"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Questionable pulse detected"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.11"/>
            </coding>
            <text value="signal-poor"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Signal is poor"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.12"/>
            </coding>
            <text value="signal-inadequate"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Signal is inadequate"/>
          </valueCodeableConcept>
        </component>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.9"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}">Vital Signs</span>, <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150456}, {http://loinc.org 59408-5}">MDC_PULS_OXIM_SAT_O2</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:39-0500</p><p><b>value</b>: 100.0 %<span style="background: LightGoldenRodYellow"> (Details: UCUM  code% = '%')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://terminology.hl7.org/CodeSystem/observation-category"/>
            <code value="vital-signs"/>
          </coding>
          <text value="Vital Signs"/>
        </category>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150456"/>
          </coding>
          <coding>
            <system value="http://loinc.org"/>
            <code value="59408-5"/>
          </coding>
          <text value="MDC_PULS_OXIM_SAT_O2"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:39-05:00"/>
        <valueQuantity>
          <value value="100.0"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="%"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.10"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}">Vital Signs</span>, <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 149530}, {http://loinc.org 8867-4}">MDC_PULS_OXIM_PULS_RATE</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:39-0500</p><p><b>value</b>: 54.0 {beat}/min<span style="background: LightGoldenRodYellow"> (Details: UCUM  code{beat}/min = '{beat}/min')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://terminology.hl7.org/CodeSystem/observation-category"/>
            <code value="vital-signs"/>
          </coding>
          <text value="Vital Signs"/>
        </category>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="149530"/>
          </coding>
          <coding>
            <system value="http://loinc.org"/>
            <code value="8867-4"/>
          </coding>
          <text value="MDC_PULS_OXIM_PULS_RATE"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:39-05:00"/>
        <valueQuantity>
          <value value="54.0"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="{beat}/min"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.11"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150320}">MDC_SAT_O2_QUAL</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:39-0500</p><p><b>value</b>: 0.82 %<span style="background: LightGoldenRodYellow"> (Details: UCUM  code% = '%')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150320"/>
          </coding>
          <text value="MDC_SAT_O2_QUAL"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:39-05:00"/>
        <valueQuantity>
          <value value="0.82"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="%"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.12"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdBitsEnumerationObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150604}">MDC_PULS_OXIM_DEV_STATUS</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:40-0500</p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.2}">sensor-displaced</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Sensor is incorrectly placed on user</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.7}">signal-pulse-questionable</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Questionable pulse detected</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.11}">signal-poor</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Signal is poor</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.12}">signal-inadequate</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Signal is inadequate</span></p></blockquote></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150604"/>
          </coding>
          <text value="MDC_PULS_OXIM_DEV_STATUS"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:40-05:00"/>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.2"/>
            </coding>
            <text value="sensor-displaced"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Sensor is incorrectly placed on user"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.7"/>
            </coding>
            <text value="signal-pulse-questionable"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Questionable pulse detected"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.11"/>
            </coding>
            <text value="signal-poor"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Signal is poor"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.12"/>
            </coding>
            <text value="signal-inadequate"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Signal is inadequate"/>
          </valueCodeableConcept>
        </component>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.13"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}">Vital Signs</span>, <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150456}, {http://loinc.org 59408-5}">MDC_PULS_OXIM_SAT_O2</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:40-0500</p><p><b>value</b>: 100.0 %<span style="background: LightGoldenRodYellow"> (Details: UCUM  code% = '%')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://terminology.hl7.org/CodeSystem/observation-category"/>
            <code value="vital-signs"/>
          </coding>
          <text value="Vital Signs"/>
        </category>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150456"/>
          </coding>
          <coding>
            <system value="http://loinc.org"/>
            <code value="59408-5"/>
          </coding>
          <text value="MDC_PULS_OXIM_SAT_O2"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:40-05:00"/>
        <valueQuantity>
          <value value="100.0"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="%"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.14"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}">Vital Signs</span>, <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 149530}, {http://loinc.org 8867-4}">MDC_PULS_OXIM_PULS_RATE</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:40-0500</p><p><b>value</b>: 54.0 {beat}/min<span style="background: LightGoldenRodYellow"> (Details: UCUM  code{beat}/min = '{beat}/min')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://terminology.hl7.org/CodeSystem/observation-category"/>
            <code value="vital-signs"/>
          </coding>
          <text value="Vital Signs"/>
        </category>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="149530"/>
          </coding>
          <coding>
            <system value="http://loinc.org"/>
            <code value="8867-4"/>
          </coding>
          <text value="MDC_PULS_OXIM_PULS_RATE"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:40-05:00"/>
        <valueQuantity>
          <value value="54.0"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="{beat}/min"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.15"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150320}">MDC_SAT_O2_QUAL</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:40-0500</p><p><b>value</b>: 0.82 %<span style="background: LightGoldenRodYellow"> (Details: UCUM  code% = '%')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150320"/>
          </coding>
          <text value="MDC_SAT_O2_QUAL"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:40-05:00"/>
        <valueQuantity>
          <value value="0.82"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="%"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.16"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdBitsEnumerationObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150604}">MDC_PULS_OXIM_DEV_STATUS</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:41-0500</p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.2}">sensor-displaced</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Sensor is incorrectly placed on user</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.7}">signal-pulse-questionable</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Questionable pulse detected</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.11}">signal-poor</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Signal is poor</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.12}">signal-inadequate</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Signal is inadequate</span></p></blockquote></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150604"/>
          </coding>
          <text value="MDC_PULS_OXIM_DEV_STATUS"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:41-05:00"/>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.2"/>
            </coding>
            <text value="sensor-displaced"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Sensor is incorrectly placed on user"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.7"/>
            </coding>
            <text value="signal-pulse-questionable"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Questionable pulse detected"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.11"/>
            </coding>
            <text value="signal-poor"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Signal is poor"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.12"/>
            </coding>
            <text value="signal-inadequate"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Signal is inadequate"/>
          </valueCodeableConcept>
        </component>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.17"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}">Vital Signs</span>, <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150456}, {http://loinc.org 59408-5}">MDC_PULS_OXIM_SAT_O2</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:41-0500</p><p><b>value</b>: 100.0 %<span style="background: LightGoldenRodYellow"> (Details: UCUM  code% = '%')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://terminology.hl7.org/CodeSystem/observation-category"/>
            <code value="vital-signs"/>
          </coding>
          <text value="Vital Signs"/>
        </category>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150456"/>
          </coding>
          <coding>
            <system value="http://loinc.org"/>
            <code value="59408-5"/>
          </coding>
          <text value="MDC_PULS_OXIM_SAT_O2"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:41-05:00"/>
        <valueQuantity>
          <value value="100.0"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="%"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.18"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}">Vital Signs</span>, <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 149530}, {http://loinc.org 8867-4}">MDC_PULS_OXIM_PULS_RATE</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:41-0500</p><p><b>value</b>: 54.0 {beat}/min<span style="background: LightGoldenRodYellow"> (Details: UCUM  code{beat}/min = '{beat}/min')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://terminology.hl7.org/CodeSystem/observation-category"/>
            <code value="vital-signs"/>
          </coding>
          <text value="Vital Signs"/>
        </category>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="149530"/>
          </coding>
          <coding>
            <system value="http://loinc.org"/>
            <code value="8867-4"/>
          </coding>
          <text value="MDC_PULS_OXIM_PULS_RATE"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:41-05:00"/>
        <valueQuantity>
          <value value="54.0"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="{beat}/min"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.19"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150320}">MDC_SAT_O2_QUAL</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:41-0500</p><p><b>value</b>: 0.82 %<span style="background: LightGoldenRodYellow"> (Details: UCUM  code% = '%')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150320"/>
          </coding>
          <text value="MDC_SAT_O2_QUAL"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:41-05:00"/>
        <valueQuantity>
          <value value="0.82"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="%"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.20"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdBitsEnumerationObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150604}">MDC_PULS_OXIM_DEV_STATUS</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:42-0500</p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.2}">sensor-displaced</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Sensor is incorrectly placed on user</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.7}">signal-pulse-questionable</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Questionable pulse detected</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.11}">signal-poor</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Signal is poor</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.12}">signal-inadequate</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Signal is inadequate</span></p></blockquote></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150604"/>
          </coding>
          <text value="MDC_PULS_OXIM_DEV_STATUS"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:42-05:00"/>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.2"/>
            </coding>
            <text value="sensor-displaced"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Sensor is incorrectly placed on user"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.7"/>
            </coding>
            <text value="signal-pulse-questionable"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Questionable pulse detected"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.11"/>
            </coding>
            <text value="signal-poor"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Signal is poor"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.12"/>
            </coding>
            <text value="signal-inadequate"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Signal is inadequate"/>
          </valueCodeableConcept>
        </component>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.21"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}">Vital Signs</span>, <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150456}, {http://loinc.org 59408-5}">MDC_PULS_OXIM_SAT_O2</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:42-0500</p><p><b>value</b>: 100.0 %<span style="background: LightGoldenRodYellow"> (Details: UCUM  code% = '%')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://terminology.hl7.org/CodeSystem/observation-category"/>
            <code value="vital-signs"/>
          </coding>
          <text value="Vital Signs"/>
        </category>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150456"/>
          </coding>
          <coding>
            <system value="http://loinc.org"/>
            <code value="59408-5"/>
          </coding>
          <text value="MDC_PULS_OXIM_SAT_O2"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:42-05:00"/>
        <valueQuantity>
          <value value="100.0"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="%"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.22"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}">Vital Signs</span>, <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 149530}, {http://loinc.org 8867-4}">MDC_PULS_OXIM_PULS_RATE</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:42-0500</p><p><b>value</b>: 54.0 {beat}/min<span style="background: LightGoldenRodYellow"> (Details: UCUM  code{beat}/min = '{beat}/min')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://terminology.hl7.org/CodeSystem/observation-category"/>
            <code value="vital-signs"/>
          </coding>
          <text value="Vital Signs"/>
        </category>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="149530"/>
          </coding>
          <coding>
            <system value="http://loinc.org"/>
            <code value="8867-4"/>
          </coding>
          <text value="MDC_PULS_OXIM_PULS_RATE"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:42-05:00"/>
        <valueQuantity>
          <value value="54.0"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="{beat}/min"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.23"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150320}">MDC_SAT_O2_QUAL</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:42-0500</p><p><b>value</b>: 0.82 %<span style="background: LightGoldenRodYellow"> (Details: UCUM  code% = '%')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150320"/>
          </coding>
          <text value="MDC_SAT_O2_QUAL"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:42-05:00"/>
        <valueQuantity>
          <value value="0.82"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="%"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.24"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdBitsEnumerationObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150604}">MDC_PULS_OXIM_DEV_STATUS</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:43-0500</p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.2}">sensor-displaced</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Sensor is incorrectly placed on user</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.7}">signal-pulse-questionable</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Questionable pulse detected</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.11}">signal-poor</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Signal is poor</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.12}">signal-inadequate</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Signal is inadequate</span></p></blockquote></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150604"/>
          </coding>
          <text value="MDC_PULS_OXIM_DEV_STATUS"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:43-05:00"/>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.2"/>
            </coding>
            <text value="sensor-displaced"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Sensor is incorrectly placed on user"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.7"/>
            </coding>
            <text value="signal-pulse-questionable"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Questionable pulse detected"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.11"/>
            </coding>
            <text value="signal-poor"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Signal is poor"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.12"/>
            </coding>
            <text value="signal-inadequate"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Signal is inadequate"/>
          </valueCodeableConcept>
        </component>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.25"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}">Vital Signs</span>, <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150456}, {http://loinc.org 59408-5}">MDC_PULS_OXIM_SAT_O2</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:43-0500</p><p><b>value</b>: 100.0 %<span style="background: LightGoldenRodYellow"> (Details: UCUM  code% = '%')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://terminology.hl7.org/CodeSystem/observation-category"/>
            <code value="vital-signs"/>
          </coding>
          <text value="Vital Signs"/>
        </category>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150456"/>
          </coding>
          <coding>
            <system value="http://loinc.org"/>
            <code value="59408-5"/>
          </coding>
          <text value="MDC_PULS_OXIM_SAT_O2"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:43-05:00"/>
        <valueQuantity>
          <value value="100.0"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="%"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.26"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}">Vital Signs</span>, <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 149530}, {http://loinc.org 8867-4}">MDC_PULS_OXIM_PULS_RATE</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:43-0500</p><p><b>value</b>: 54.0 {beat}/min<span style="background: LightGoldenRodYellow"> (Details: UCUM  code{beat}/min = '{beat}/min')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://terminology.hl7.org/CodeSystem/observation-category"/>
            <code value="vital-signs"/>
          </coding>
          <text value="Vital Signs"/>
        </category>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="149530"/>
          </coding>
          <coding>
            <system value="http://loinc.org"/>
            <code value="8867-4"/>
          </coding>
          <text value="MDC_PULS_OXIM_PULS_RATE"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:43-05:00"/>
        <valueQuantity>
          <value value="54.0"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="{beat}/min"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.27"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150320}">MDC_SAT_O2_QUAL</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:43-0500</p><p><b>value</b>: 0.2 %<span style="background: LightGoldenRodYellow"> (Details: UCUM  code% = '%')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150320"/>
          </coding>
          <text value="MDC_SAT_O2_QUAL"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:43-05:00"/>
        <valueQuantity>
          <value value="0.2"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="%"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.28"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdBitsEnumerationObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150604}">MDC_PULS_OXIM_DEV_STATUS</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:44-0500</p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.2}">sensor-displaced</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Sensor is incorrectly placed on user</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.7}">signal-pulse-questionable</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Questionable pulse detected</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.11}">signal-poor</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Signal is poor</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.12}">signal-inadequate</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Signal is inadequate</span></p></blockquote></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150604"/>
          </coding>
          <text value="MDC_PULS_OXIM_DEV_STATUS"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:44-05:00"/>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.2"/>
            </coding>
            <text value="sensor-displaced"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Sensor is incorrectly placed on user"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.7"/>
            </coding>
            <text value="signal-pulse-questionable"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Questionable pulse detected"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.11"/>
            </coding>
            <text value="signal-poor"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Signal is poor"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.12"/>
            </coding>
            <text value="signal-inadequate"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Signal is inadequate"/>
          </valueCodeableConcept>
        </component>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.29"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}">Vital Signs</span>, <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150456}, {http://loinc.org 59408-5}">MDC_PULS_OXIM_SAT_O2</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:44-0500</p><p><b>value</b>: 100.0 %<span style="background: LightGoldenRodYellow"> (Details: UCUM  code% = '%')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://terminology.hl7.org/CodeSystem/observation-category"/>
            <code value="vital-signs"/>
          </coding>
          <text value="Vital Signs"/>
        </category>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150456"/>
          </coding>
          <coding>
            <system value="http://loinc.org"/>
            <code value="59408-5"/>
          </coding>
          <text value="MDC_PULS_OXIM_SAT_O2"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:44-05:00"/>
        <valueQuantity>
          <value value="100.0"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="%"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.30"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}">Vital Signs</span>, <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 149530}, {http://loinc.org 8867-4}">MDC_PULS_OXIM_PULS_RATE</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:44-0500</p><p><b>value</b>: 54.0 {beat}/min<span style="background: LightGoldenRodYellow"> (Details: UCUM  code{beat}/min = '{beat}/min')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://terminology.hl7.org/CodeSystem/observation-category"/>
            <code value="vital-signs"/>
          </coding>
          <text value="Vital Signs"/>
        </category>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="149530"/>
          </coding>
          <coding>
            <system value="http://loinc.org"/>
            <code value="8867-4"/>
          </coding>
          <text value="MDC_PULS_OXIM_PULS_RATE"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:44-05:00"/>
        <valueQuantity>
          <value value="54.0"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="{beat}/min"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.31"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150320}">MDC_SAT_O2_QUAL</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:44-0500</p><p><b>value</b>: 0.2 %<span style="background: LightGoldenRodYellow"> (Details: UCUM  code% = '%')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150320"/>
          </coding>
          <text value="MDC_SAT_O2_QUAL"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:44-05:00"/>
        <valueQuantity>
          <value value="0.2"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="%"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.32"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdBitsEnumerationObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150604}">MDC_PULS_OXIM_DEV_STATUS</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:45-0500</p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.2}">sensor-displaced</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Sensor is incorrectly placed on user</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.7}">signal-pulse-questionable</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Questionable pulse detected</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.11}">signal-poor</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Signal is poor</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.12}">signal-inadequate</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Signal is inadequate</span></p></blockquote></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150604"/>
          </coding>
          <text value="MDC_PULS_OXIM_DEV_STATUS"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:45-05:00"/>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.2"/>
            </coding>
            <text value="sensor-displaced"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Sensor is incorrectly placed on user"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.7"/>
            </coding>
            <text value="signal-pulse-questionable"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Questionable pulse detected"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.11"/>
            </coding>
            <text value="signal-poor"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Signal is poor"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.12"/>
            </coding>
            <text value="signal-inadequate"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Signal is inadequate"/>
          </valueCodeableConcept>
        </component>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.33"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}">Vital Signs</span>, <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150456}, {http://loinc.org 59408-5}">MDC_PULS_OXIM_SAT_O2</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:45-0500</p><p><b>value</b>: 100.0 %<span style="background: LightGoldenRodYellow"> (Details: UCUM  code% = '%')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://terminology.hl7.org/CodeSystem/observation-category"/>
            <code value="vital-signs"/>
          </coding>
          <text value="Vital Signs"/>
        </category>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150456"/>
          </coding>
          <coding>
            <system value="http://loinc.org"/>
            <code value="59408-5"/>
          </coding>
          <text value="MDC_PULS_OXIM_SAT_O2"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:45-05:00"/>
        <valueQuantity>
          <value value="100.0"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="%"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.34"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}">Vital Signs</span>, <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 149530}, {http://loinc.org 8867-4}">MDC_PULS_OXIM_PULS_RATE</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:45-0500</p><p><b>value</b>: 54.0 {beat}/min<span style="background: LightGoldenRodYellow"> (Details: UCUM  code{beat}/min = '{beat}/min')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://terminology.hl7.org/CodeSystem/observation-category"/>
            <code value="vital-signs"/>
          </coding>
          <text value="Vital Signs"/>
        </category>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="149530"/>
          </coding>
          <coding>
            <system value="http://loinc.org"/>
            <code value="8867-4"/>
          </coding>
          <text value="MDC_PULS_OXIM_PULS_RATE"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:45-05:00"/>
        <valueQuantity>
          <value value="54.0"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="{beat}/min"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.35"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150320}">MDC_SAT_O2_QUAL</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:45-0500</p><p><b>value</b>: 0.2 %<span style="background: LightGoldenRodYellow"> (Details: UCUM  code% = '%')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150320"/>
          </coding>
          <text value="MDC_SAT_O2_QUAL"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:45-05:00"/>
        <valueQuantity>
          <value value="0.2"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="%"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.36"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdBitsEnumerationObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150604}">MDC_PULS_OXIM_DEV_STATUS</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:46-0500</p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.2}">sensor-displaced</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Sensor is incorrectly placed on user</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.7}">signal-pulse-questionable</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Questionable pulse detected</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.11}">signal-poor</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Signal is poor</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.12}">signal-inadequate</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Signal is inadequate</span></p></blockquote></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150604"/>
          </coding>
          <text value="MDC_PULS_OXIM_DEV_STATUS"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:46-05:00"/>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.2"/>
            </coding>
            <text value="sensor-displaced"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Sensor is incorrectly placed on user"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.7"/>
            </coding>
            <text value="signal-pulse-questionable"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Questionable pulse detected"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.11"/>
            </coding>
            <text value="signal-poor"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Signal is poor"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.12"/>
            </coding>
            <text value="signal-inadequate"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Signal is inadequate"/>
          </valueCodeableConcept>
        </component>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.37"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}">Vital Signs</span>, <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150456}, {http://loinc.org 59408-5}">MDC_PULS_OXIM_SAT_O2</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:46-0500</p><p><b>value</b>: 100.0 %<span style="background: LightGoldenRodYellow"> (Details: UCUM  code% = '%')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://terminology.hl7.org/CodeSystem/observation-category"/>
            <code value="vital-signs"/>
          </coding>
          <text value="Vital Signs"/>
        </category>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150456"/>
          </coding>
          <coding>
            <system value="http://loinc.org"/>
            <code value="59408-5"/>
          </coding>
          <text value="MDC_PULS_OXIM_SAT_O2"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:46-05:00"/>
        <valueQuantity>
          <value value="100.0"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="%"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.38"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}">Vital Signs</span>, <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 149530}, {http://loinc.org 8867-4}">MDC_PULS_OXIM_PULS_RATE</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:46-0500</p><p><b>value</b>: 54.0 {beat}/min<span style="background: LightGoldenRodYellow"> (Details: UCUM  code{beat}/min = '{beat}/min')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://terminology.hl7.org/CodeSystem/observation-category"/>
            <code value="vital-signs"/>
          </coding>
          <text value="Vital Signs"/>
        </category>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="149530"/>
          </coding>
          <coding>
            <system value="http://loinc.org"/>
            <code value="8867-4"/>
          </coding>
          <text value="MDC_PULS_OXIM_PULS_RATE"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:46-05:00"/>
        <valueQuantity>
          <value value="54.0"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="{beat}/min"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.39"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150320}">MDC_SAT_O2_QUAL</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:46-0500</p><p><b>value</b>: 0.2 %<span style="background: LightGoldenRodYellow"> (Details: UCUM  code% = '%')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150320"/>
          </coding>
          <text value="MDC_SAT_O2_QUAL"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:46-05:00"/>
        <valueQuantity>
          <value value="0.2"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="%"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.40"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdBitsEnumerationObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150604}">MDC_PULS_OXIM_DEV_STATUS</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:47-0500</p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.2}">sensor-displaced</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Sensor is incorrectly placed on user</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.7}">signal-pulse-questionable</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Questionable pulse detected</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.10}">signal-low-perfusion</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Signal experiencing low perfusion</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.11}">signal-poor</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Signal is poor</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.12}">signal-inadequate</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Signal is inadequate</span></p></blockquote></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150604"/>
          </coding>
          <text value="MDC_PULS_OXIM_DEV_STATUS"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:47-05:00"/>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.2"/>
            </coding>
            <text value="sensor-displaced"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Sensor is incorrectly placed on user"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.7"/>
            </coding>
            <text value="signal-pulse-questionable"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Questionable pulse detected"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.10"/>
            </coding>
            <text value="signal-low-perfusion"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Signal experiencing low perfusion"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.11"/>
            </coding>
            <text value="signal-poor"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Signal is poor"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.12"/>
            </coding>
            <text value="signal-inadequate"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Signal is inadequate"/>
          </valueCodeableConcept>
        </component>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.41"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}">Vital Signs</span>, <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150456}, {http://loinc.org 59408-5}">MDC_PULS_OXIM_SAT_O2</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:47-0500</p><p><b>value</b>: 100.0 %<span style="background: LightGoldenRodYellow"> (Details: UCUM  code% = '%')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://terminology.hl7.org/CodeSystem/observation-category"/>
            <code value="vital-signs"/>
          </coding>
          <text value="Vital Signs"/>
        </category>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150456"/>
          </coding>
          <coding>
            <system value="http://loinc.org"/>
            <code value="59408-5"/>
          </coding>
          <text value="MDC_PULS_OXIM_SAT_O2"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:47-05:00"/>
        <valueQuantity>
          <value value="100.0"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="%"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.42"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories vital-signs}">Vital Signs</span>, <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 149530}, {http://loinc.org 8867-4}">MDC_PULS_OXIM_PULS_RATE</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:47-0500</p><p><b>value</b>: 54.0 {beat}/min<span style="background: LightGoldenRodYellow"> (Details: UCUM  code{beat}/min = '{beat}/min')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="vital-signs"/>
          </coding>
          <text value="Vital Signs"/>
        </category>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="149530"/>
          </coding>
          <coding>
            <system value="http://loinc.org"/>
            <code value="8867-4"/>
          </coding>
          <text value="MDC_PULS_OXIM_PULS_RATE"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:47-05:00"/>
        <valueQuantity>
          <value value="54.0"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="{beat}/min"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.43"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150320}">MDC_SAT_O2_QUAL</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:47-0500</p><p><b>value</b>: 0.05 %<span style="background: LightGoldenRodYellow"> (Details: UCUM  code% = '%')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150320"/>
          </coding>
          <text value="MDC_SAT_O2_QUAL"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:47-05:00"/>
        <valueQuantity>
          <value value="0.05"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="%"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.44"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdBitsEnumerationObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150604}">MDC_PULS_OXIM_DEV_STATUS</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:48-0500</p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.2}">sensor-displaced</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Sensor is incorrectly placed on user</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.7}">signal-pulse-questionable</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Questionable pulse detected</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.10}">signal-low-perfusion</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Signal experiencing low perfusion</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.11}">signal-poor</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Signal is poor</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 150604.12}">signal-inadequate</span></p><p><b>value</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">Signal is inadequate</span></p></blockquote></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150604"/>
          </coding>
          <text value="MDC_PULS_OXIM_DEV_STATUS"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:48-05:00"/>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.2"/>
            </coding>
            <text value="sensor-displaced"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Sensor is incorrectly placed on user"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.7"/>
            </coding>
            <text value="signal-pulse-questionable"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Questionable pulse detected"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.10"/>
            </coding>
            <text value="signal-low-perfusion"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Signal experiencing low perfusion"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.11"/>
            </coding>
            <text value="signal-poor"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Signal is poor"/>
          </valueCodeableConcept>
        </component>
        <component>
          <code>
            <coding>
              <system
                      value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
              <code value="150604.12"/>
            </coding>
            <text value="signal-inadequate"/>
          </code>
          <valueCodeableConcept>
            <coding>
              <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
              <code value="Y"/>
            </coding>
            <text value="Signal is inadequate"/>
          </valueCodeableConcept>
        </component>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.45"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}">Vital Signs</span>, <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150456}, {http://loinc.org 59408-5}">MDC_PULS_OXIM_SAT_O2</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:48-0500</p><p><b>value</b>: 100.0 %<span style="background: LightGoldenRodYellow"> (Details: UCUM  code% = '%')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://terminology.hl7.org/CodeSystem/observation-category"/>
            <code value="vital-signs"/>
          </coding>
          <text value="Vital Signs"/>
        </category>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150456"/>
          </coding>
          <coding>
            <system value="http://loinc.org"/>
            <code value="59408-5"/>
          </coding>
          <text value="MDC_PULS_OXIM_SAT_O2"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:48-05:00"/>
        <valueQuantity>
          <value value="100.0"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="%"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.46"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}">Vital Signs</span>, <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 149530}, {http://loinc.org 8867-4}">MDC_PULS_OXIM_PULS_RATE</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:48-0500</p><p><b>value</b>: 54.0 {beat}/min<span style="background: LightGoldenRodYellow"> (Details: UCUM  code{beat}/min = '{beat}/min')</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://terminology.hl7.org/CodeSystem/observation-category"/>
            <code value="vital-signs"/>
          </coding>
          <text value="Vital Signs"/>
        </category>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="149530"/>
          </coding>
          <coding>
            <system value="http://loinc.org"/>
            <code value="8867-4"/>
          </coding>
          <text value="MDC_PULS_OXIM_PULS_RATE"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:48-05:00"/>
        <valueQuantity>
          <value value="54.0"/>
          <system value="http://unitsofmeasure.org"/>
          <code value="{beat}/min"/>
        </valueQuantity>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
  <entry>
    <fullUrl value="urn:oid:1.0.0.47"/>
    <resource>
      <Observation>
        <meta>
          <profile
                   value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
        </meta>
        <text>
          <status value="generated"/>
          <div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_null"> </a><p class="res-header-id"><b>Generated Narrative: Observation </b></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}">PHD generated Observation</span></p><p><b>code</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 150320}">MDC_SAT_O2_QUAL</span></p><p><b>subject</b>: <a href="Patient-patientExample-1.html">Sisansarah Lorianthah Piggy  (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-11 19:07:48-0500</p><p><b>dataAbsentReason</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/data-absent-reason not-a-number}">not-a-number (Not a number)</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>
        </text>
        <extension
                   url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
          <valueReference>🔗 
            <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
          </valueReference>
        </extension>
        <status value="final"/>
        <category>
          <coding>
            <system
                    value="http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"/>
            <code value="phd-observation"/>
          </coding>
        </category>
        <code>
          <coding>
            <system value="urn:iso:std:iso:11073:10101"/>
            <code value="150320"/>
          </coding>
          <text value="MDC_SAT_O2_QUAL"/>
        </code>
        <subject>🔗 
          <reference value="Patient/patientExample-1"/>
        </subject>
        <effectiveDateTime value="2018-11-11T19:07:48-05:00"/>
        <dataAbsentReason>
          <coding>
            <system
                    value="http://terminology.hl7.org/CodeSystem/data-absent-reason"/>
            <code value="not-a-number"/>
          </coding>
          <text value="not-a-number (Not a number)"/>
        </dataAbsentReason>
        <device>🔗 
          <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
        </device>
      </Observation>
    </resource>
    <request>
      <method value="POST"/>
      <url value="Observation"/>
    </request>
  </entry>
</Bundle>