This page is part of the Personal Health Device FHIR IG (v0.3.0: STU 1 Ballot 3) based on FHIR R4. The current version which supercedes this version is 1.0.0. For a full list of available versions, see the Directory of published versions
Narrative view of the Value Set
<ValueSet xmlns="http://hl7.org/fhir"> <id value="Quantity11073MDC"/> <meta> <profile value="http://hl7.org/fhir/StructureDefinition/shareablevalueset"/> </meta> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><h2>Quantity 11073 Attributes</h2><div><p>ValueSet for the ISO/IEEE 11073-10101 Nomenclatures Describing 11073-20601 attributes whose values are Quantities.</p> </div><p>This value set includes codes from the following code systems:</p><ul><li>Include these codes as defined in <code>urn:iso:std:iso:11073:10101</code><table class="none"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td></tr><tr><td>68073</td><td>High-resolution relative time</td><td/></tr><tr><td>67914</td><td>Accuracy of Measurement</td><td/></tr><tr><td>68222</td><td>Resolution of absolute time clock</td><td/></tr><tr><td>68226</td><td>Resolution of Base offset time clock</td><td/></tr><tr><td>68223</td><td>Resolution of relative time clock</td><td/></tr><tr><td>68224</td><td>Resolution of high-resolution relative time clock</td><td/></tr><tr><td>68224</td><td>Time synchronization accuracy</td><td/></tr><tr><td>68229</td><td>Tick Resolution</td><td/></tr></table></li></ul></div> </text> <url value="http://hl7.org/fhir/uv/phd/ValueSet/Quantity11073MDC"/> <version value="0.3.0"/> <name value="Quantity11073MDC"/> <title value="Quantity 11073 Attributes"/> <status value="draft"/> <experimental value="false"/> <date value="2018-11-23T00:00:00+11:00"/> <publisher value="Health Level Seven International (Health Care Devices Work Group)"/> <description value="ValueSet for the ISO/IEEE 11073-10101 Nomenclatures Describing 11073-20601 attributes whose values are Quantities."/> <compose> <include> <system value="urn:iso:std:iso:11073:10101"/> <concept> <code value="68073"/> <display value="High-resolution relative time"/> </concept> <concept> <code value="67914"/> <display value="Accuracy of Measurement"/> </concept> <concept> <code value="68222"/> <display value="Resolution of absolute time clock"/> </concept> <concept> <code value="68226"/> <display value="Resolution of Base offset time clock"/> </concept> <concept> <code value="68223"/> <display value="Resolution of relative time clock"/> </concept> <concept> <code value="68224"/> <display value="Resolution of high-resolution relative time clock"/> </concept> <concept> <code value="68224"/> <display value="Time synchronization accuracy"/> </concept> <concept> <code value="68229"/> <display value="Tick Resolution"/> </concept> </include> </compose> </ValueSet>