PhdImplementationGuide 0.3.0 - STU 1 (2nd ballot)

This page is part of the Personal Health Device FHIR IG (v0.3.0: STU 1 Ballot 3) based on FHIR R4. The current version which supercedes this version is 1.0.0. For a full list of available versions, see the Directory of published versions

Example of PHD Device - XML Representation

(back to narrative)

Raw xml


<Device xmlns="http://hl7.org/fhir">
  <id value="phd-74E8FFFEFF051C00.001C05FFE874"/>
  <meta>
    <profile value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdDevice"/>
  </meta>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: phd-74E8FFFEFF051C00.001C05FFE874</p><p><b>meta</b>: </p><p><b>identifier</b>: IEEE 11073 System Identifier = 74-E8-FF-FE-FF-05-1C-00, Bluetooth MAC address = 00-1C-05-FF-E8-74</p><p><b>manufacturer</b>: Nonin_Medical_Inc.</p><p><b>serialNumber</b>: 501900083</p><p><b>modelNumber</b>: Model 3230</p><p><b>type</b>: MDC_MOC_VMS_MDS_SIMP <span style="background: LightGoldenRodYellow">(Details : {urn:iso:std:iso:11073:10101 code '65573' = '65573)</span></p><h3>Specializations</h3><table class="grid"><tr><td>-</td><td><b>SystemType</b></td><td><b>Version</b></td></tr><tr><td>*</td><td>MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter <span style="background: LightGoldenRodYellow">(Details : {urn:iso:std:iso:11073:10101 code '528388' = '528388)</span></td><td>1</td></tr></table><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_FW: Firmware revision <span style="background: LightGoldenRodYellow">(Details : {urn:iso:std:iso:11073:10101 code '531976' = '531976)</span></p><p><b>value</b>: r2.1</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_SW: Software revision <span style="background: LightGoldenRodYellow">(Details : {urn:iso:std:iso:11073:10101 code '531975' = '531975)</span></p><p><b>value</b>: r1.5 9.7</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_HW: Hardware revision <span style="background: LightGoldenRodYellow">(Details : {urn:iso:std:iso:11073:10101 code '531974' = '531974)</span></p><p><b>value</b>: r1.0</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version <span style="background: LightGoldenRodYellow">(Details : {urn:iso:std:iso:11073:10101 code '532352' = '532352)</span></p><p><b>value</b>: 6.0</p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: certified device list as transport-specialization combo <span style="background: LightGoldenRodYellow">(Details : {urn:iso:std:iso:11073:10101 code '532353' = '532353)</span></p><p><b>valueCode</b>: BTLE Pulse Oximeter certified <span style="background: LightGoldenRodYellow">(Details : {http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD code '32772' = 'BTLE Pulse Oximeter certified)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: regulation-status <span style="background: LightGoldenRodYellow">(Details : {http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 code '532354.0' = 'If bit is cleared device is regulated)</span></p><p><b>valueCode</b>: Device is Regulated <span style="background: LightGoldenRodYellow">(Details : {http://terminology.hl7.org/CodeSystem/v2-0136 code 'N' = 'No)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style="background: LightGoldenRodYellow">(Details : {urn:iso:std:iso:11073:10101 code '68220' = '68220)</span></p><p><b>valueCode</b>: MDC_TIME_SYNC_NONE: <span style="background: LightGoldenRodYellow">(Details : {urn:iso:std:iso:11073:10101 code '532224' = '532224)</span></p></blockquote></div>
  </text>
  <identifier>
    <type>
      <coding>
        <system
                value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers"/>
        <code value="SYSID"/>
      </coding>
    </type>
    <system value="urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"/>
    <value value="74-E8-FF-FE-FF-05-1C-00"/>
  </identifier>
  <identifier>
    <type>
      <coding>
        <system
                value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers"/>
        <code value="BTMAC"/>
      </coding>
    </type>
    <system value="http://hl7.org/fhir/sid/eui-48"/>
    <value value="00-1C-05-FF-E8-74"/>
  </identifier>
  <manufacturer value="Nonin_Medical_Inc."/>
  <serialNumber value="501900083"/>
  <modelNumber value="Model 3230"/>
  <type>
    <coding>
      <system value="urn:iso:std:iso:11073:10101"/>
      <code value="65573"/>
    </coding>
    <text value="MDC_MOC_VMS_MDS_SIMP"/>
  </type>
  <specialization>
    <systemType>
      <coding>
        <system value="urn:iso:std:iso:11073:10101"/>
        <code value="528388"/>
      </coding>
      <text value="MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter"/>
    </systemType>
    <version value="1"/>
  </specialization>
  <version>
    <type>
      <coding>
        <system value="urn:iso:std:iso:11073:10101"/>
        <code value="531976"/>
      </coding>
      <text value="MDC_ID_PROD_SPEC_FW: Firmware revision"/>
    </type>
    <value value="r2.1"/>
  </version>
  <version>
    <type>
      <coding>
        <system value="urn:iso:std:iso:11073:10101"/>
        <code value="531975"/>
      </coding>
      <text value="MDC_ID_PROD_SPEC_SW: Software revision"/>
    </type>
    <value value="r1.5 9.7"/>
  </version>
  <version>
    <type>
      <coding>
        <system value="urn:iso:std:iso:11073:10101"/>
        <code value="531974"/>
      </coding>
      <text value="MDC_ID_PROD_SPEC_HW: Hardware revision"/>
    </type>
    <value value="r1.0"/>
  </version>
  <version>
    <type>
      <coding>
        <system value="urn:iso:std:iso:11073:10101"/>
        <code value="532352"/>
      </coding>
      <text value="MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version"/>
    </type>
    <value value="6.0"/>
  </version>
  <property>
    <type>
      <coding>
        <system value="urn:iso:std:iso:11073:10101"/>
        <code value="532353"/>
      </coding>
      <text
            value="MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: certified device list as transport-specialization combo"/>
    </type>
    <valueCode>
      <coding>
        <system value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD"/>
        <code value="32772"/>
      </coding>
    </valueCode>
  </property>
  <property>
    <type>
      <coding>
        <system value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
        <code value="532354.0"/>
      </coding>
      <text value="regulation-status"/>
    </type>
    <valueCode>
      <coding>
        <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
        <code value="N"/>
      </coding>
      <text value="Device is Regulated"/>
    </valueCode>
  </property>
  <property>
    <type>
      <coding>
        <system value="urn:iso:std:iso:11073:10101"/>
        <code value="68220"/>
      </coding>
      <text value="MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"/>
    </type>
    <valueCode>
      <coding>
        <system value="urn:iso:std:iso:11073:10101"/>
        <code value="532224"/>
      </coding>
      <text value="MDC_TIME_SYNC_NONE:"/>
    </valueCode>
  </property>
</Device>