This page is part of the Personal Health Device FHIR IG (v0.3.0: STU 1 Ballot 3) based on FHIR R4. The current version which supercedes this version is 1.0.0. For a full list of available versions, see the Directory of published versions
@prefix fhir: <http://hl7.org/fhir/> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix xsd: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- a fhir:Device; fhir:nodeRole fhir:treeRoot; fhir:Resource.id [ fhir:value "phd-74E8FFFEFF051C00.001C05FFE874"]; fhir:Resource.meta [ fhir:Meta.profile [ fhir:value "http://hl7.org/fhir/uv/phd/StructureDefinition/PhdDevice"; fhir:index 0; fhir:link <http://hl7.org/fhir/uv/phd/StructureDefinition/PhdDevice> ] ]; fhir:DomainResource.text [ fhir:Narrative.status [ fhir:value "generated" ]; fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: phd-74E8FFFEFF051C00.001C05FFE874</p><p><b>meta</b>: </p><p><b>identifier</b>: IEEE 11073 System Identifier = 74-E8-FF-FE-FF-05-1C-00, Bluetooth MAC address = 00-1C-05-FF-E8-74</p><p><b>manufacturer</b>: Nonin_Medical_Inc.</p><p><b>serialNumber</b>: 501900083</p><p><b>modelNumber</b>: Model 3230</p><p><b>type</b>: MDC_MOC_VMS_MDS_SIMP <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '65573' = '65573)</span></p><h3>Specializations</h3><table class=\"grid\"><tr><td>-</td><td><b>SystemType</b></td><td><b>Version</b></td></tr><tr><td>*</td><td>MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '528388' = '528388)</span></td><td>1</td></tr></table><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_FW: Firmware revision <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '531976' = '531976)</span></p><p><b>value</b>: r2.1</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_SW: Software revision <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '531975' = '531975)</span></p><p><b>value</b>: r1.5 9.7</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_HW: Hardware revision <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '531974' = '531974)</span></p><p><b>value</b>: r1.0</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '532352' = '532352)</span></p><p><b>value</b>: 6.0</p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: certified device list as transport-specialization combo <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '532353' = '532353)</span></p><p><b>valueCode</b>: BTLE Pulse Oximeter certified <span style=\"background: LightGoldenRodYellow\">(Details : {http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD code '32772' = 'BTLE Pulse Oximeter certified)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: regulation-status <span style=\"background: LightGoldenRodYellow\">(Details : {http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 code '532354.0' = 'If bit is cleared device is regulated)</span></p><p><b>valueCode</b>: Device is Regulated <span style=\"background: LightGoldenRodYellow\">(Details : {http://terminology.hl7.org/CodeSystem/v2-0136 code 'N' = 'No)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '68220' = '68220)</span></p><p><b>valueCode</b>: MDC_TIME_SYNC_NONE: <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '532224' = '532224)</span></p></blockquote></div>" ]; fhir:Device.identifier [ fhir:index 0; fhir:Identifier.type [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers" ]; fhir:Coding.code [ fhir:value "SYSID" ] ] ]; fhir:Identifier.system [ fhir:value "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680" ]; fhir:Identifier.value [ fhir:value "74-E8-FF-FE-FF-05-1C-00" ] ], [ fhir:index 1; fhir:Identifier.type [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers" ]; fhir:Coding.code [ fhir:value "BTMAC" ] ] ]; fhir:Identifier.system [ fhir:value "http://hl7.org/fhir/sid/eui-48" ]; fhir:Identifier.value [ fhir:value "00-1C-05-FF-E8-74" ] ]; fhir:Device.manufacturer [ fhir:value "Nonin_Medical_Inc."]; fhir:Device.serialNumber [ fhir:value "501900083"]; fhir:Device.modelNumber [ fhir:value "Model 3230"]; fhir:Device.type [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "urn:iso:std:iso:11073:10101" ]; fhir:Coding.code [ fhir:value "65573" ] ]; fhir:CodeableConcept.text [ fhir:value "MDC_MOC_VMS_MDS_SIMP" ] ]; fhir:Device.specialization [ fhir:index 0; fhir:Device.specialization.systemType [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "urn:iso:std:iso:11073:10101" ]; fhir:Coding.code [ fhir:value "528388" ] ]; fhir:CodeableConcept.text [ fhir:value "MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter" ] ]; fhir:Device.specialization.version [ fhir:value "1" ] ]; fhir:Device.version [ fhir:index 0; fhir:Device.version.type [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "urn:iso:std:iso:11073:10101" ]; fhir:Coding.code [ fhir:value "531976" ] ]; fhir:CodeableConcept.text [ fhir:value "MDC_ID_PROD_SPEC_FW: Firmware revision" ] ]; fhir:Device.version.value [ fhir:value "r2.1" ] ], [ fhir:index 1; fhir:Device.version.type [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "urn:iso:std:iso:11073:10101" ]; fhir:Coding.code [ fhir:value "531975" ] ]; fhir:CodeableConcept.text [ fhir:value "MDC_ID_PROD_SPEC_SW: Software revision" ] ]; fhir:Device.version.value [ fhir:value "r1.5 9.7" ] ], [ fhir:index 2; fhir:Device.version.type [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "urn:iso:std:iso:11073:10101" ]; fhir:Coding.code [ fhir:value "531974" ] ]; fhir:CodeableConcept.text [ fhir:value "MDC_ID_PROD_SPEC_HW: Hardware revision" ] ]; fhir:Device.version.value [ fhir:value "r1.0" ] ], [ fhir:index 3; fhir:Device.version.type [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "urn:iso:std:iso:11073:10101" ]; fhir:Coding.code [ fhir:value "532352" ] ]; fhir:CodeableConcept.text [ fhir:value "MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version" ] ]; fhir:Device.version.value [ fhir:value "6.0" ] ]; fhir:Device.property [ fhir:index 0; fhir:Device.property.type [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "urn:iso:std:iso:11073:10101" ]; fhir:Coding.code [ fhir:value "532353" ] ]; fhir:CodeableConcept.text [ fhir:value "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: certified device list as transport-specialization combo" ] ]; fhir:Device.property.valueCode [ fhir:index 0; fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD" ]; fhir:Coding.code [ fhir:value "32772" ] ] ] ], [ fhir:index 1; fhir:Device.property.type [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7" ]; fhir:Coding.code [ fhir:value "532354.0" ] ]; fhir:CodeableConcept.text [ fhir:value "regulation-status" ] ]; fhir:Device.property.valueCode [ fhir:index 0; fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/v2-0136" ]; fhir:Coding.code [ fhir:value "N" ] ]; fhir:CodeableConcept.text [ fhir:value "Device is Regulated" ] ] ], [ fhir:index 2; fhir:Device.property.type [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "urn:iso:std:iso:11073:10101" ]; fhir:Coding.code [ fhir:value "68220" ] ]; fhir:CodeableConcept.text [ fhir:value "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol" ] ]; fhir:Device.property.valueCode [ fhir:index 0; fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "urn:iso:std:iso:11073:10101" ]; fhir:Coding.code [ fhir:value "532224" ] ]; fhir:CodeableConcept.text [ fhir:value "MDC_TIME_SYNC_NONE:" ] ] ]. # - ontology header ------------------------------------------------------------ a owl:Ontology; owl:imports fhir:fhir.ttl.